SAMSUNG LTA460WS-L04 Specification

Page 1
Preliminary
Preliminary
DATE : 17.Apr.2006
SAMSUNG TFT--
SAMSUNG TFT
SAMSUNG TFT-LCD
MODEL
MODEL
MODEL : LTA460WS-L04
The Information Described in this Specification is Preliminary and can be changed without prior notice
LCD
LCD
: LTA460WS--
: LTA460WS
L04
L04
APPROVAED BY
Product Planning Group 3, Marketing Team
Samsung Electronics Co . , LTD.
DATE
17.Apr.2006
PREPARED BY
Yu-Geun Lee
DATE
17.Apr.2006
1/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 2
Contents
Revision History -------------------------------------------------------------------------------------------- (3) General Description --------------------------------------------------------------------------------------- (4) General Information --------------------------------------------------------------------------------------- (4)
1. Absolute Maximum Ratings -------------------------------------------------------------------------- (5)
2. Optical Characteristics --------------------------------------------------------------------------------- (7)
3. Electrical Characteristics ----------------------------------------------------------------------------- (10)
3.1 TFT LCD Module
3.2 Back Light Unit
3.3 Inverter Input & Specification
4. Block Diagram ------------------------------------------------------------------------------------------- (13)
5. Input Terminal Pin Assignment --------------------------------------------------------------------- (14)
5.1 Input Signal & Power
5.2 Inverter Input Pin Configuration
5.3 Inverter Input Power Sequence
5.4 LVDS Interface
5.5 Input Signals, Basic Display Colors and Gray Scale of Each Color
6. Interface Timing ---------------------------------------------------------------------------------------- (19)
6.1 Timing Parameters (DE only mode)
6.2 Timing Diagrams of interface Signal (DE only mode)
6.3 Power ON/OFF Sequence
7. Outline Dimension -------------------------------------------------------------------------------------- (22)
8. Packing --------------------------------------------------------------------------------------------------- (24)
9. Marking & Others --------------------------------------------------------------------------------------- (25)
10. General Precaution ----------------------------------------------------------------------------------- (26)
10.1 Handling
10.2 Storage
10.3 Operation
10.4 Operation Condition Guide
10.5 Others
2/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 3
* Revision History
Date
17,
2006
Rev.
No
SummaryPage
First issuedall000Apr
3/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 4
General Description
Description
LTA460WS-L04 is a color active matrix liquid crystal display (LCD) that uses amorphous silicon TFT(Thin Film Transistor) as switching components. This model is composed of a TFT LCD panel, a driver circuit and a back light unit. The resolution of a 46.0“ is 1366 x 768 and this model can display up to 16.7 million colors with wide viewing angle of 89° or higher in all directions. This panel is intended to support applications to provide a excellent performance for Flat Panel Display such as Home-alone Multimedia TFT-LCD TV, Display terminals for AV application products, and High Definition TV (HDTV).
Features
RoHS compliance (Pb-free)High contrast ratio, high aperture ratio, fast response timeSPVA(Super Patterned Vertical Align) modeWide viewing angle (±178°)High speed responseWXGA (1366 x 768 pixels) resolution (16:9)Low Power consumptionDirect Type 24 CCFTs(Cold Cathode Fluorescent Tube)DE(Data Enable) modeLVDS (Low Voltage Differential Signaling) interface (1pixel/clock)
General Information
Module Size
1083.0(W
Haze 44% , Hard-coating (3H)Surface Treatment
RGB vertical stripePixel Arrangement
57.5(D
Normally BlackDisplay Mode
500 (Typ)Luminance of White
) x 627.0(H
TYP
MAX
UnitSpecificationItems
)
TYP
)
mm
g16,500(Max)Weight mm0.7455(H) x 0.7455(V)Pixel Pitch mm1018.353(H) x 572.544(V)Active Display Area
colors8 bit - 16.7MDisplay Colors
pixel1366 x 768Number of Pixels
cd/m
2
Note
±1.0mm
16:9
4/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 5
1. Absolute Maximum Ratings
If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable
damage to the device.
NoteUnitMax.Min.SymbolItem
Power Supply Voltage
Storage temperature
Glass surface
Center
DD
STG
OPR
temperature
S
nop
T
x,y 40
nop
-
(Operation)
T. Uniformity
Shock ( non - operating )
Vibration ( non - operating )
Note (1) Ta= 25 ± 2 °C
(2) Temperature and relative humidity range are shown in the figure below.
a. 90 % RH Max. (Ta ≤ 39 °C) b. Relative Humidity is 90% or less. (Ta > 39 °C)
c. No condensation (3) 11ms, sine wave, one time for ±X, ±Y, ±Z axis (4) 10-300 Hz, Sweep rate 10min, 30min for X,Y,Z axis
(1)V5.5GND-0.5V 60-20T 500T
℃ ℃
(2)
(2),(5)
10-
(3)G 30-z
(4)G1.5-V
Fig. Temperature and Relative humidity range
5/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 6
(5) Definition of test point
5mm
5mm
12
5
LCD Module (Active)
3
T should be less than 10
T
: Temperature of the center of the glass surface (Test point 5)
OPR
(T = | T
T1~ T4 : Temperature of each edge of the glass surface T
: The highest temperature of the glass surface
MAX
4
OPR–TMAX
| )
6/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 7
2. Optical Characteristics
The optical characteristics should be measured in a dark room or equivalent.
Measuring equipment : TOPCON BM-7,SPECTRORADIOMETER SR-3
Contrast Ratio
(Center of screen)
Response
Time
Luminance of White
(Center of screen)
Color
Chromaticity
(CIE 1931)
Rising
Falling
Red
Green
Blue
White
(Ta = 25 ± 2°C, VDD = 5V, fv = 60Hz, f
TgG-to-G
L
Rx
Normal
θL,R=0
θU,D=0
Viewing
Angle
TYP.
-0.03
0.648
0.333Ry
0.283Gx
0.603Gy
0.141Bx
0.066By
0.292Wx
0.301Wy
= 80MHz, IL= 6.0mArms)
DCLK
-1200-C/R
1310-Tr
76-Tf
msec
-8-
2
-500400Y
cd/m
TYP.
+0.03
NoteUnitMax.Typ.Min.ConditionSymbolItem
(3)
SR-3
(5)
BM-7
(6)
SR-3
(7),(8)
SR-3
θ
Hor.
Viewing
Angle
Ver.
L
R
U
D
Brightness Uniformity
(9 Points)
uni
Note (1) Test Equipment Setup
The measurement should be executed in a stable, windless and dark room between 40min and 60min after lighting the back light at the given temperature for stabilization of the back light. This should be measured in the center of screen.
Single lamp current : 6.0mA Environment condition : Ta = 25 ± 2 °C
C/R10
%-72--Color Gamut
K-8500--Color Temperature
(7)
SR-3
(7)
SR-3
-8975
-8975θ Degree
-8975θ
(8)
SR-3
-8975θ
%25--B
(4)
SR-3
7/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 8
Field Photo detector
1°SR-3
Photo detector
2°BM-7
TFT - LCD Module
Note (2) Definition of test point
228 683 1138
128
384
Field
The center of the screen
Active Area
Test Point
⑤④
SR-3 : 50 BM-7 : 50
LCD Panel
640
Note (3) Definition of Contrast Ratio (C/R)
: Ratio of gray max (Gmax) & gray min (Gmin) at the center point of the panel
G
CR
/
max
=
G
min
Gmax : Luminance with all pixels white Gmin : Luminance with all pixels black
8/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 9
Note (4) Definition of 9 points brightness uniformity
Buni
BB
=∗
(max min)
100
B
max
Bmax : Maximum brightness Bmin : Minimum brightness
Note (5) Definition of Response time : Sum of Tr, Tf
Display data
Optical Instruments
Response
100%
Black (data off)
T
R
White (data on)
90%
10%
0%
White (data off)
T
F
TIME
Note (6) Definition of Luminance of White : Luminance of white at center point Note (7) Definition of Color Chromaticity (CIE 1931)
Color coordinate of Red, Green, Blue & White at center point
Note (8) Definition of Viewing Angle
: Viewing angle range (C/R ≥ 10)
9/ 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 10
3. Electrical Characteristics
3.1 TFT LCD Module
The connector for display data & timing signal should be connected.
Ta = 25°C ± 2 °C
NoteUnitMax.Typ.Min.SymbolItem
Voltage of Power Supply
Current
(a) Black
of Power
DD
I
DD
Supply
Vsync Frequency Hsync Frequency Main Frequency Rush Current
V
H
DCLK
RUSH
Note (1) The ripple voltage should be controlled under 10% of VDD.
V = 60Hz, fDCLK = 80MHz, V
(2) f
= 5.0V, DC Current.
DD
(3) Power dissipation check pattern (LCD Module only)
a) Black Pattern b) White Pattern c) N-Pattern
(1)V5.55.04.5V mA-1750­mA-2000-(b) White
(2),(3)
mA26002300-(c) N-Pattern
Hz-60-f
kHz-50.1846.3f
MHz908065f
(4)A6--I
(4) Measurement Conditions
100%
90%
10% GND
Rush Current I
RUSH
T
=470
RUSH
can be measured when T
. is 470㎲.
RUSH
V
DD
10 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 11
3.2 Back Light Unit
The back light unit contains 20 direct-lighting type CCFTs ( Cold Cathode Fluorescent
Tube ). The characteristics of lamps are shown in the following tables.
Ta=25 ± 2°C
NoteUnitMax.Typ.Min.SymbolItem Lamp Current Lamp Voltage
L
L
mArms7.05.53.0I
Vrms194017801700V
(1)Hour--50,000HrOperating Life Time
Note (1) It is defined as the time to take until the brightness reduces to 50% of its original value.
[Operating condition : Ta = 25±2℃, IL = 6.0mArms(typ.), For single lamp only]
Inverter
Inverter
HOT 1
HOT 2
HOT 1
HOT 2
Inverter
Inverter
LCD
Module
HOT 23
HOT 23
HOT 24
HOT 24
11 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 12
3.3 Inverter Input Condition & Specification
ConditionsSymbolItems
Specifications
NoteUnit
Max.Typ.Min.
Input
Voltage
Input
Current
Lamp
Current
Frequency
Backlight
On/Off
Dimming
Control
I
RUSH
LAMP
V
O
DIM
Vin=24.0V
Vdim=3.3V
Ta=25±2 °CV252423-Vin
A9.358.5-
mArms6.05.55.0Vdim=3.3 VI
kHz7067.565Vin=24.0 VF
After 60 min
Warm-up
-
-
5.25-2.4Vin=24.0 VON
-V
0.8-0Vin=24.0 VOFF
--3.3Max Lum
-V
0--Min. Lum
12 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 13
4. Block Diagram
CONTROL PCB
USER CONNECTOR TIMING CONTROLLER
DC/DC STEP DOWN
DC/DC CONVERTOR
(AV
DD/VDD/VON/VOFF
DATA
CONTROL
VIN(5.0V)
AV
VON/V
V
COM
Y VOLTAGE
VDD(3.3V) VDD(2.5V)
DD
OFF
)
GAMMA-GENERATOR
V
-GENERATOR
COM
R-STRING + FB
SSC
MEMORY(DCC)
FPC
FPC
SOURCE
PCB
SOURCE
PCB
DATA DRIVER
IC
LTA460WS
PANEL
DATA DRIVER
IC
GATE DRIVER
IC
13 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 14
5. Input Terminal Pin Assignment
5.1 Input Signal & Power Connector : FI-E30S (JAE)
DescriptionPIN No.DescriptionPIN No.
GND16No Connection1
RxIN3-17No Connection2
RxIN3+18No Connection3
GND19GND4
No Connection20RxIN0-5
LVDS OPTION (Note 1)21RxIN0+6
No Connection22GND7
GND23RxIN1-8 GND24RxIN1+9 GND25GND10
Vin26RxIN2-11 Vin27RxIN2+12 Vin28GND13
Note No Connection :This PINS are only used for SAMSUNG internal using.
(1) LVDS OPTION :If this PIN : HIGH (3.3 V) Normal LVDS format
: LOW (GND) JEIDA LVDS format
SEQUENCE :On = V
OFF = Interface Signal(T3) LVDS Option ≥ V
DD(T1) LVDS Option Interface Signal(T2)
DD
Vin29RxCLK-14 Vin30RxCLK+15
14 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 15
Note (2) Pin number starts from Right side
Pin No. 1 Pin No. 30
#1 #30
PCB
#1
#30
Fig. Connector diagram
a. All GND pins should be connected together and also be connected to the LCD’s
metal chassis. b. All power input pins should be connected together. c. All NC pins should be separated from other signal or power.
15 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 16
5.2 Inverter Input Pin Configuration
Pin Configuration(FUNCTION)Pin No.
Backlight On /Off [ON:2.4 - 5.25 V, OFF: 0 - 0.8 V]12
Dimming Control [0V:Min, 3.3V:Max]13
Connector : 20022WR-14AML(YEONHO)
24 V1 24 V2 24 V3 24 V4 24 V5 GND6 GND7 GND8 GND9 GND10
No Connection11
5.3 Inverter Input Power Sequence
0.9 Vin
Vin (24V)
Dimming Control ( 0 ~ 3.3 V )
Back Light On/Off
20msec [Min]
0.1 Vin
0.5sec [Min]
0.5sec [Min]
No Connection14
1.1sec [Min]
0.5sec [Min]
2.4 V
0.1sec [Min]
16 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 17
5.4 LVDS Interface
- LVDS Receiver : Tcon (merged)
- Data Format (JEIDA & Normal)
VESA -DATAJEIDA -DATALVDS pin
R0R2TxIN/RxOUT0 R1R3TxIN/RxOUT1 R2R4TxIN/RxOUT2
TxOUT/RxIN0
TxOUT/RxIN1
TxOUT/RxIN2
R3R5TxIN/RxOUT3 R4R6TxIN/RxOUT4 R5R7TxIN/RxOUT6 G0G2TxIN/RxOUT7 G1G3TxIN/RxOUT8 G2G4TxIN/RxOUT9 G3G5TxIN/RxOUT12 G4G6TxIN/RxOUT13 G5G7TxIN/RxOUT14 B0B2TxIN/RxOUT15 B1B3TxIN/RxOUT18 B2B4TxIN/RxOUT19 B3B5TxIN/RxOUT20 B4B6TxIN/RxOUT21 B5B7TxIN/RxOUT22
TxOUT/RxIN3
HSYNCHSYNCTxIN/RxOUT24 VSYNCVSYNCTxIN/RxOUT25
DENDENTxIN/RxOUT26
R6R0TxIN/RxOUT27 R7R1TxIN/RxOUT5 G6G0TxIN/RxOUT10 G7G1TxIN/RxOUT11
B6B0TxIN/RxOUT16 B7B1TxIN/RxOUT17
RESERVEDRESERVEDTxIN/RxOUT23
17 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 18
5.5 Input Signals, Basic Display Colors and Gray Scale of Each Color
COLOR
BASIC
COLOR
GRAY
SCALE
OF
RED
GRAY
SCALE
OF
GREEN
GRAY
SCALE
OF
BLUE
DISPLAY
(8bit)
DARK
LIGHT
DARK
LIGHT
DARK
LIGHT
DATA SIGNAL
BLUEGREENRED
1111111100000000CYAN
1111111111111WHITE
:::::
00000000011111111RED
:::::::::
:::::::::::::
::::::::::::: ::::::::::::::::::
::::::::: ::::::::::::::::::
000001111111100000000GREEN
::::: ::::::::::::::::::
GRAY SCALE LEVEL
B7B6B5B4B3B2B1B0G7G6G5G4G3G2G1G0R7R6R5R4R3R2R1R0
-000000000000000000000000BLACK
-111111110000000000000000BLUE
-000000001111111100000000GREEN
-11111111
-000000000000000011111111RED
-111111110000000011111111MAGENTA
-000000001111111111111111YELLOW
-11111111111 R0000000000000000000000000BLACK R1000000000000000000000001 R2000000000000000000000010
R3~
R252
R253000000000000000011111101 R254000000000000000011111110 R2550000000
G0000000000000000000000000BLACK G1000000000000000100000000 G2000000000000001000000000
G3~
G252
G253000000001111110100000000 G254000000001111111000000000 G255000
B0000000000000000000000000BLACK B1000000010000000000000000 B2000000100000000000000000
B3~
B252
B253111111010000000000000000 B254111111100000000000000000 B255111111110000000000000000BLUE
Note) Definition of Gray :
Rn : Red Gray, Gn : Green Gray, Bn : Blue Gray (n = Gray level) Input Signal : 0 = Low level voltage, 1 = High level voltage
18 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 19
6. Interface Timing
6.1 Timing Parameters (DE only mode)
NOTEUnitMAX.TYP.MIN.SYMBOLITEMSIGNAL
Clock
Hsync
Vsync
Frequency
C
H
V
Active
Vertical
Display
Period
VD
Display Term
Vertical
Total
VB
Active
Horizontal
Display
Period
HD
Display Term
Horizontal
Total
H
Note) This product is DE only mode. The input of Hsync & Vsync signal does
not have an effect on normal operation. (1) Test Point : TTL control signal and CLK at LVDS Tx input terminal in system (2) Internal V
DD = 3.3V
-MHz9080651/T
-KHz-50.1846.3F
-Hz-60-F
-Lines-768-T
-Lines-838773T
-clocks-1366-T
-clocks170016001570T
19 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 20
6.2 Timing diagrams of interface signal (DE only mode)
TV
DE
DE
DCLK
DATA
SIGNALS
TVD
TVB
TH
THD
TC
DCLK
DISPLAY
DATA
DE
TC
TCH
TDS TDH
TES
TCL
0.5 V
0.5 V
CC
0.5 V
CC
CC
20 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 21
6.3 Power ON/OFF Sequence
To prevent a latch-up or DC operation of the LCD Module, the power on/off
sequence should be as the diagram below.
0<T110msec
0<T250msec
0<T350msec
1000msecT4
500msecT5
(Recommend Value)
100msecT6
(Recommend Value)
2.4 V
T1 : VDDrising time from 10% to 90% T2 : The time from V T3 : The time from valid data off to V T4 : V
off time for Windows restart
DD
to valid data at power ON.
DD
off at power Off.
DD
T5 : The time from valid data to B/L enable at power ON. T6 : The time from valid data off to B/L disable at power Off.
The supply voltage of the external system for the Module input should be the same
as the definition of V
DD
.
Apply the lamp voltage within the LCD operation range. When the back light turns on
before the LCD operation or the LCD turns off before the back light turns off, the display may momentarily show abnormal screen.
In case of V
= off level,
DD
please keep the level of input signals low or keep a high impedance.
T4 should be measured after the Module has been fully discharged between power off
and on period.
Interface signal should not be kept at high impedance when the power is on.
21 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 22
7. Outline Dimension (Front View)
Model LTA460WS-L04 Doc. No 05-000-G-060417 Page 22 / 28
Page 23
7. Outline Dimension (Rear View)
Model LTA460WS-L04 Doc. No 05-002-G-060417 Page 23 / 28
Page 24
8. PACKING
8.1 CARTON (Internal Package)
(1) Packing Form
Corrugated fiberboard box and corrugated cardboard as shock absorber
(2) Packing Method
Packing
-Pallet Box
Cushion-Foam
LCD Module
Direction be able to open it
Cushion-Foam
Pallet-Plastic
8.2 Packing Specification
LCD Packing
10ea / (Packing-
1Box / PalletPallet
Pallet Box)
VerticalPacking Direction
186.8kgTotal Pallet Weight
RemarkSpecificationItem
1. 160 Kg / LCD (10ea)
2. 10 Kg / Cushion-pallet (2ea)
3. 8 Kg / Packing-Pallet Box (1ea)
4. Cushion-pallet Material : EPS
5. Packing-Pallet Box Material : DW4
1. Pallet weight = 8.8kg
2. 8.8Kg/Pallet
1270mm(H) x 1150mm(V) x 844mm(height)H x V x heightTotal Pallet Size Pallet(8.8kg) + Module(16*10=160) +
Cushion(up+botton=10kg) + Pallet-BOX(8kg)
24 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 25
9. MARKING & OTHERS
A nameplate bearing followed by is affixed to a shipped product at the specified
location on each product.
(1) Parts number : LTA460WS-L04 (2) Revision: Three letters (3) Lot number : X X X X XXX XX X
Cell Position No. (In the Glass) Glass No. (In the one Lot) Lot No. (Glass) Month Year (Note1) Product code Line
(4) Nameplate Indication
Week code : 05 29
LTA460WS-L04
XXXXXXXXXX XXX
(5) Packing box attach
LTA460WS-L04
week year
40mm
Revision code Lot number
80mm
100mm
Part number
XXXX
10
Box serial number
165mm
(6) Others
1. After service part Lamps cannot be replaced because of the narrow bezel structure.
25 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 26
10. General Precautions
10.1 Handling
(a) When the Module is assembled, it should be attached to the system firmly
using all mounting holes. Be careful not to twist and bend the Module.
(b) Because the inverter use high voltage, it should be disconnected from power
before it is assembled or disassembled.
(c) Refrain from strong mechanical shock and / or any force to the Module.
In addition to damage, this may cause improper operation or damage to the Module and CCFT back light.
(d) Note that polarizers are very fragile and could be damage easily.
Do not press or scratch the surface harder than a HB pencil lead.
(e) Wipe off water droplets or oil immediately. If you leave the droplets for a long
time, staining or discoloration may occur. (f) If the surface of the polarizer is dirty, clean it using absorbent cotton or soft cloth. (g) Desirable cleaners are water, IPA(Isopropyl Alcohol) or Hexane.
Do not use Ketone type materials(ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid
or Methyl chloride. It might permanent damage to the polarizer due to chemical
reaction. (h) If the liquid crystal material leaks from the panel, it should be kept away
from the eyes or mouth . In case of contact with hands, legs or clothes, it must
be washed away with soap thoroughly. (i) Protect the Module from static, or the CMOS Gate Array IC would be damaged. (j) Use finger-stalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process. (k) Do not disassemble the Module. (l) Do not pull or fold the lamp wire. (m) Do not adjust the variable resistor located on the Module. (n) Protection film for polarizer on the Module should be slowly peeled off just before use
so that the electrostatic charge can be minimized.
(o) Pins of I/F connector should not be touched directly with bare hands.
26 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 27
10.2 Storage
(a) Do not leave the Module in high temperature, and high humidity for a long time.
It is highly recommended to store the Module with temperature from 0 to 35
and relative humidity of less than 70%. (b) Do not store the TFT- L CD Module in direct sunlight. (c) The Module should be stored in a dark place. It is prohibited to apply sunlight or
fluorescent light in storing.
10.3 Operation
(a) Do not connect or disconnect the Module in the "Power On" condition. (b) Power supply should always be turned on/off by the "Power on/off sequence" (c) Module has high frequency circuits. Sufficient suppression to the electromagnetic
interference should be done by system manufacturers. Grounding and shielding methods may be important to minimize the interference.
(d) The cable between the back light connector and its inverter power supply should
be connected directly with a minimized length. A longer cable between the back light and the inverter may cause lower luminance of lamp(CCFT) and may require higher startup voltage(Vs).
10.4 Operation Condition Guide
(a) The LCD product should be operated under normal conditions.
Normal condition is defined as below;
- Temperature : 20±15℃
- Humidity : 55±20%
- Display pattern : continually changing pattern (Not stationary)
(b) If the product will be used in extreme conditions such as high temperature,
humidity, display patterns or operation time etc.., It is strongly recommended to contact SEC for Application engineering advice. O therwise, its reliability and function may not be guaranteed. Extreme conditions are commonly found at Airports, Transit Stations, Banks, Stock market, and Controlling systems.
27 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Page 28
10.5 Others
(a) Ultra-violet ray filter is necessary for outdoor operation. (b) Avoid condensation of water. It may result in improper operation or disconnection
of electrode.
(c) Do not exceed the absolute maximum rating value. ( supply voltage variation,
input voltage variation, variation in part contents and environmental temperature, and so on) Otherwise the Module may be damaged.
(d) If the Module keeps displaying the same pattern for a long period of time,
the image may be "sticked" to the screen. To avoid image sticking, it is recommended to use a screen saver.
(e) This Module has its circuitry PCB's on the rear side and should be handled
carefully in order not to be stressed.
(f) Please contact SEC in advance when you display the same pattern for a long time.
28 / 28Page05-000-G-060417Doc. NoLTA460WS-L04MODEL
Loading...