Samsung DVG45T3200W, DVE45T3200W User Manual

Dryer
User manual
DVE(G)45T3200*
DV3200T_DC68-03784N-00_EN.indd 1 2020-05-25  11:10:17
Contents
Contents
What you need to know about the safety instructions 4 Important safety symbols 4 CALIFORNIA PROPOSITION 65 WARNING 8 Important safety precautions 8 Warnings 9 Cautions 10
Installation requirements 12
Key installation requirements 12 Location considerations 12 Ducting requirements 15 Mobile home installation 16 Exhausting requirements 17 Gas requirements 18 Electrical requirements 19
Installation 22
What’s included 22 Step-by-step installation 24 Vent blockage test 28 Exhaust ducting guide 31 Switching the door position 31
Before you start 34
Sort and load 34 Functional prerequisite 34
Operations 35
Feature panel 35 Simple steps to start 36 Cycle overview 37 Cycle chart 38 Cycle guide 39 Special features 40
English2
DV3200T_DC68-03784N-00_EN.indd 2 2020-05-25  11:10:17
Maintenance 41
Cleaning 41
Troubleshooting 42
Checkpoints 42 Information codes 46
Specications 47
Fabric care chart 47 Protecting the environment 48 Specication sheet 49
Contents
English 3
DV3200T_DC68-03784N-00_EN.indd 3 2020-05-25  11:10:17
SAVE THESE INSTRUCTIONS

Safety information

Congratulations on your new Samsung dryer. This manual contains important information on the installation, use and care of your appliance. Please take some time to read this manual to take full advantage of your dryer’s many benets and features.
Safety information

What you need to know about the safety instructions

Please read this manual thoroughly to ensure that you know how to safely and efciently operate the extensive features and functions of your new appliance. Please store the manual in a safe location close to the appliance for future reference. Use this appliance only for its intended purpose as described in this instruction manual.
Warnings and Important Safety Instructions in this manual do not cover all possible conditions and situations that may occur. It is your responsibility to use common sense, caution and care when installing, maintaining and operating your dryer.
Because the following operating instructions cover various models, the characteristics of your dryer may differ slightly from those described in this manual and not all warning signs may be applicable. If you have any questions or concerns, contact your nearest service center or nd help and information online at www.samsung.com.

Important safety symbols

What the icons and signs in this user manual mean:
WARNING
Hazards or unsafe practices that may result in severe personal injury, death and/or property damage.
CAUTION
Hazards or unsafe practices that may result in personal injury and/or property damage.
NOTE
Indicates that a risk of personal injury or material damage exists.
These warning signs are here to prevent injury to yourself and others. Please follow them explicitly. After reading this manual, store it in a safe place for future reference.
Read all instructions before using the appliance. As with any equipment that uses electricity and moving parts, potential hazards exist.
To safely operate this appliance, familiarize yourself with its operation and exercise care when using it.
English4
DV3200T_DC68-03784N-00_EN.indd 4 2020-05-25  11:10:17
SAVE THESE INSTRUCTIONSSAVE THESE INSTRUCTIONS
WARNING - Risk of Fire
• Clothes dryer installation must be performed by a qualied installer.
• Install the clothes dryer according to the manufacturer’s instructions and local codes.
• Do not install a clothes dryer with exible plastic venting materials. If exible metal (foil type) duct is installed, it must be of a specic type identied by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airow and increase the risk of re.
• Do not install a booster fan in the exhaust duct.
• To reduce the risk of severe injury or death, follow all installation instructions.
Safety information
• Save these instructions.
English 5
DV3200T_DC68-03784N-00_EN.indd 5 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONS
Safety information
SAVE THESE INSTRUCTIONS
WARNING - To reduce the risk of re or explosion:
Safety information
• Do not dry items that have been previously cleaned, washed, soaked, or spotted with gasoline, dry cleaning solvents, or other ammable or explosive substances. They emit vapors that could ignite or explode. Any material that has been in contact with a cleaning solvent or ammable liquids or solids should not be placed in the dryer until all traces of these ammable liquids or solids and their fumes have been removed. There are many highly ammable items used in homes, such as acetone, denatured alcohol, gasoline, kerosene, some liquid household cleaners, some spot removers, turpentine, waxes, and wax removers.
• Items containing foam rubber (which may be labeled latex foam) or similarly textured rubberlike materials must not be dried on a heat setting. Heated foam rubber materials can, under certain circumstances, ignite spontaneously.
WARNING - Fire or explosion hazard
• Failure to follow safety warnings exactly could result in serious injury, death or property damage.
• Do not store or use gasoline or other ammable vapors and liquids near this or any other appliance.
• Installation and service must be performed by a qualied installer, service agency, or the gas supplier.
• Do not install a booster fan in the exhaust duct.
English6
DV3200T_DC68-03784N-00_EN.indd 6 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONSSAVE THESE INSTRUCTIONS
WARNING - What to do if you smell gas:
• Do not try to light any appliance.
• Do not turn on the appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
Safety information
English 7
DV3200T_DC68-03784N-00_EN.indd 7 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONS
Safety information
SAVE THESE INSTRUCTIONS

CALIFORNIA PROPOSITION 65 WARNING

Safety information
WARNING
Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Important safety precautions

WARNING
To reduce the risk of re, electric shock, or injury to persons when using your appliance, follow basic precautions, including the following:
1. Read all instructions before using this appliance.
2. Do not dry articles that have been previously cleaned in, washed in, soaked in,
or spotted with gasoline, dry-cleaning solvents, or other ammable or explosive substances, as they give off vapors that could ignite or explode.
3. Do not use the dryer to dry clothes which have traces of any ammable substance, such as vegetable oil, cooking oil, machine oil, ammable chemicals, paint thinner, etc., or anything containing wax or chemicals, such as mops and cleaning cloths. Flammable substances may cause the fabric to catch re by itself.
4. Do not store or use gasoline or other ammable vapors and liquids near this or any other appliance.
5. Do not allow children to play on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
6. Before the appliance is removed from service or discarded, remove the door to the drying compartment.
7. Do not reach into the appliance if the drum is moving.
8. Do not install or store this appliance where it will be exposed to the weather.
9. Do not tamper with internal controls.
10. Do not repair or replace any part of the appliance or attempt any service unless
specically recommended in the user-maintenance instructions or in published user­repair instructions that you understand and have the skills to carry out.
11. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
12. Clean the lint screen before or after each load.
English8
DV3200T_DC68-03784N-00_EN.indd 8 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONSSAVE THESE INSTRUCTIONS
13. Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
14. Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
15. The interior of the appliance and exhaust duct should be cleaned periodically by qualied service personnel.
16. Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch re. To reduce the risk of re due to contaminated loads, the nal part of a tumble dryer cycle occurs without heat (cool down period). Avoid stopping a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated.
17. This appliance must be grounded. See “Electrical requirements” and “Grounding” inInstallation” section.
18. Do not allow children to play on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
19. Do not insert your hand under the dryer.
This may result in injury.
20. Take care that children’s ngers are not caught in the door when closing it.
This may result in injury.
21. Control board and inlet valve are intentionally not grounded and may present a risk of electric shock only during servicing.
Do not contact this part while appliance is energized.
Safety information

Warnings

WARNING
Ensure pockets are free from small, irregularly shaped hard objects, foreign material, etc. ie. coins, knives, pins, etc. These objects could damage your dryer.
Gas leaks may occur in your system, resulting in a dangerous situation.
English 9
DV3200T_DC68-03784N-00_EN.indd 9 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONS
Safety information
SAVE THESE INSTRUCTIONS

Cautions

Safety information
CAUTION
Do not allow children or pets to play on, in, or in front of the appliance. Close supervision is necessary when the appliance is used near children and pets.
Before discarding or removing your dryer from service, remove the door to the drying compartment to prevent children or animals from becoming trapped inside.
Do not reach into the appliance when the drum is moving.
Do not install or store this appliance where it will be exposed to the weather.
Do not tamper with controls.
Do not repair, replace, or attempt to service any part of the appliance unless specically instructed to in the user-repair instructions and you have the understanding and skills to carry out the procedure.
Do not use fabric softeners or products to eliminate static unless the softener or product is recommended for dryer use by the manufacturer of the fabric softener or product.
Clean the lint screen before or after each load.
Keep the area around the exhaust opening and surrounding areas free from lint, dust, and dirt.
The interior of the dryer and exhaust duct should be cleaned periodically by qualied service personnel.
This appliance must be properly grounded. Never plug the power cord into a receptacle that is not grounded adequately or not in accordance with local and national codes. See installation instructions for information about grounding this appliance.
Do not sit on top of the dryer.
Do not wash clothing with large buckles, buttons, or other heavy metal or solid objects.
Gas leaks may not be detected by smell alone.
Gas suppliers recommend you purchase and install a UL-approved gas detector.
Install and use in accordance with the manufacturer’s instructions.
Do not place items in your dryer that have been spotted or soaked with vegetable oil or cooking oil. Even after being washed, these items may contain signicant amounts of these oils.
English10
DV3200T_DC68-03784N-00_EN.indd 10 2020-05-25  11:10:18
SAVE THESE INSTRUCTIONSSAVE THESE INSTRUCTIONS
• Residual oil on clothing can ignite spontaneoulsy. The potential for spontaneous combustion increases when items containing vegetable oil or cooking oil are exposed to heat. Heat sources such as your dryer can warm these items, allowing an oxidation reaction in the oil to occur. Oxidation creates heat. If this heat cannot escape, the items can become hot enough to catch re. Piling, stacking, or storing these kinds of items may prevent heat from escaping and can create a re hazard.
• All washed and unwashed fabrics that contain vegetable oil or cooking oil can be dangerous. Washing these items in hot water with extra detergent will reduce, but not eliminate, the hazard. Always use the Cool Down cycle for these items to reduce their temperature. Never remove these items from the dryer hot or interrupt the drying cycle until the items have run through the Cool Down cycle. Never pile or stack these items when they are hot.
Safety information
English 11
DV3200T_DC68-03784N-00_EN.indd 11 2020-05-25  11:10:18

Installation requirements

Read through the following instructions before installing the dryer, and keep this manual for future reference.
WARNING
Certain internal parts are intentionally not grounded and may present a risk of electric shock only during servicing.
Installation requirements
Service Personnel - Do not contact the following parts while the appliance is energized: Control board and inlet valve.

Key installation requirements

A grounded electrical outlet.
A power cord for electric dryers (except in Canada).
Gas lines (for gas models) that must meet national and local regulations.
An exhaust system made of rigid metal or exible stiff-walled metal exhaust ducting.
WARNING
Remove the door from all discarded appliances to prevent a child from suffocating.

Location considerations

Adequate clearances between the dryer and adjacent walls or other surfaces.
Adequate air circulation for ventilation and gas combustion.
Away from water and weather.
WARNING
Make sure to exhaust the dryer outdoors to reduce the risk of re.
Keep the dryer area clear of combustible materials, gasoline, and other ammable vapors and liquids.
Do not install other fuel-burning appliances around or in the same place as the dryer.
Place the dryer at least 18 in. (460 mm) above the oor for garage installation.
English12
DV3200T_DC68-03784N-00_EN.indd 12 2020-05-25  11:10:18
Dimensions
A
Dimensions
(in. (mm))
U
Installation requirements
9
Type Front loading dryer
A. Overall height 43.9 (1114)
B. Width 27.0 (686)
C. Depth with door open 50.1 (1273)
D. Depth 30.2 (768)
English 13
DV3200T_DC68-03784N-00_EN.indd 13 2020-05-25  11:10:18
Installation requirements
Clearance requirement
This clearance requirement is applicable for dryers only.
NOTE
Installation requirements
• For washer’s clearance requirement, see the washer’s user manual.
• If the washer and dryer have different clearance requirements, use the one with the larger value.
Alcove or closet installations
WARNING
• The dryer must be exhausted to the outside to reduce the risk of re when installed in an alcove or closet.
• No other fuel-burning appliance should be installed in the same closet as the dryer.
• Place the dryer at least 18 in. (460 mm) above the oor for garage installation.
Minimum clearance for stable operation:
Sides Top Rear Front
1 in. / 25 mm 17 in. / 432 mm 5.9 in. / 150 mm 1 in. / 25 mm
If both the washer and a dryer are installed in the same location, the front of the alcove or closet must have two unobstructed air openings for a combined minimum total area of 72 in.² (465 cm²).
This clearance requirement is applicable for washer and dryer pair installation.
Side by side installation
B
A A C D
A 1 in. (25 mm) B 21 in. (533 mm) C 1 in. (25 mm) D 5.9 in. (150 mm)
English14
DV3200T_DC68-03784N-00_EN.indd 14 2020-05-25  11:10:18

Ducting requirements

Weather hood
type
Recommended Use only for short-run installation
Installation requirements
4” (10.2 cm)
No. of 90°
elbows
0 80 ft. (24.4 m) 74 ft. (22.6 m) 1 68 ft. (20.7 m) 62 ft. (18.9 m) 2 57 ft. (17.4 m) 51 ft. (15.5 m) 3 47 ft. (14.3 m) 41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
Rigid Rigid
2.5” (6.4 cm)
If you integrate the dryer’s vent system with an existing exhaust system, make sure:
The exhaust system meets all applicable local, state, and national regulations.
Not to use a exible plastic duct.
To regularly check and clean all lint buildup from inside the existing ducts.
The duct is not kinked or crushed.
The exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column or be less than 0. Note that these values are measured with the dryer running with a manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler must be empty and lint lter clean.
English 15
DV3200T_DC68-03784N-00_EN.indd 15 2020-05-25  11:10:18
Installation requirements

Mobile home installation

The installation of the dryer in mobile homes must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280 {formerly the Federal Standard
Installation requirements
for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the United States) or CSA Standards Z240 (for Canada).
When installing a dryer in a mobile home, you must make provisions for anchoring the dryer to the oor.
Locate the dryer in an area that has adequate fresh air. A minimum of 72 in² (465 cm²) of unobstructed space is required. Call 1-800-SAMSUNG (726-7864) for information on purchasing the Floor Anchoring Kit
as an accessory. All mobile home installations must be exhausted to the outside with the exhaust duct
termination securely fastened to the mobile home structure, using materials that will not support combustion.
The exhaust duct may not terminate underneath the mobile home. See Exhausting section for more information.
English16
DV3200T_DC68-03784N-00_EN.indd 16 2020-05-25  11:10:18

Exhausting requirements

The dryer must not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a concealed space of a building. Exhausting the dryer to the outside will prevent large amounts of lint and moisture from being blown into the room.
In the United States and Canada
• All dryers must be exhausted to the outside.
• The required exhaust duct is 4 inches (10.2 cm) in diameter.
• See “Ducting requirements” in the “Installation” section for the maximum duct length and number of bends that can be used.
• The total length of exible metal duct must not exceed 7’ 101/2” (2.4 m).
• Do not assemble the duct with screws or other fastener means that extend into the duct and catch lint.
For the United States only: Use only those foil-type exible ducts, if any, specically identied for use with the appliance by the manufacturer and that comply with the Outline for Clothes Dryer Transition Duct. Use Subject 2158A.
Outside the United States and Canada
• Refer to the local codes.
WARNING
• You must exhaust the dryer to the outside to reduce the risk of re when you install the dryer in an alcove or closet.
• Do not use a plastic or non-metal exible duct.
• If your existing ductwork is plastic, non­metal, or combustible, replace it with metal.
• Use only a metal exhaust duct that is non-ammable to ensure containment of exhaust air, heat, and lint.
Installation requirements
English 17
DV3200T_DC68-03784N-00_EN.indd 17 2020-05-25  11:10:18
Installation requirements

Gas requirements

WARNING
Use only natural or LP (liquid propane)
Installation requirements
gases.
The installation must be conformed with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1/NFPA 54, latest revision(for the UNITED STATES), or with the natural gas and propane installation code, CSA B149.1(for Canada).
Gas dryers are equipped with a burner vent for use with natural gas. If you plan to use your dryer with LP (liquid propane) gas, it must be converted for safe and proper performance by a qualied service technician. (LNG models only) You must check the burner of your model and use the proper LP Kit accordingly. To check the detail information of the burner, open the door and check the rating label location on the door frame.
- 20,000 BTU: LPKIT-4/XAA (DC98-04114A)
- 22,000 BTU: LPKIT-3/XAA (DC99-00792A)
A 1/2” (1.27 cm) gas supply line is recommended and must be reduced to connect to the 3/8” (1 cm) gas line on your dryer. The National Fuel Gas Code requires that an accessible, approved manual gas shut-off valve be installed within 6” of your dryer.
Gas dryers installed in residential garages must be raised 18 inches (46 cm) above the oor.
Additionally, a 1/8” (0.3 cm) N.P.T. (National Pipe Thread) plugged tapping, accessible for test gauge connection, must be installed immediately upstream of your dryer’s gas supply connection.
Your dryer must be disconnected from the gas supply pipe system during any pressure testing of the system at pressures greater than 1/2 psi (3.5 kPa).
Do not reuse old exible metal gas lines. Flexible gas lines must be designed and certied by the standard for connectors for Gas Appliances, ANSI Z21.24 • CSA 6.10.
NOTE
Your dryer uses an automatic ignition system to ignite the burner. There is no constant burning pilot.
Any pipe joint compound used must be resistant to the action of any liqueed petroleum gas.
As a courtesy, most local gas utilities will inspect a gas appliance installation.
Commonwealth of Massachusetts installation instructions
Your dryer must be installed by a licensed plumber or gas tter. A “T” handle manual gas valve must be installed in the gas supply line to your dryer. If a exible gas connector is used to install your dryer, the connector can be no longer than 3’ (36”).
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
Gas leaks may not be detected by smell alone.
Gas suppliers recommend you purchase and install a UL-approved gas detector.
Install and use in accordance with the manufacturer’s instructions.
English18
DV3200T_DC68-03784N-00_EN.indd 18 2020-05-25  11:10:19

Electrical requirements

The wiring diagram is located on the plate under the control panel or rear frame.
WARNING
• Improperly connecting the equipment grounding conductor can result in a risk of electric shock. Check with a qualied electrician or serviceman if you are in doubt as to whether your dryer is properly grounded. Do not modify the plug provided with your dryer – if it doesn’t t the outlet, have a proper outlet installed by a qualied electrician.
• To prevent unnecessary risk of re, electrical shock, or personal injury, all wiring and grounding must be done in accordance with local codes, or in the absence of local codes, in accordance with the National Electrical Code, ANSI/ NFPA No. 70-Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes and ordinances. It is your responsibility to provide adequate electrical service for your dryer.
• All gas installations must be done in accordance with the national Fuel Code ANSI/Z2231 – Latest Revision (for the U.S.) or CAN/CGA – B149 Installation Codes – Latest Revision (for Canada) and local codes and ordinances.
Grounding
This dryer must be grounded. In the event of malfunction or breakdown, the ground will reduce the risk of electrical shock by providing a path of least resistance for the electrical current.
Gas models
WARNING
• Your dryer has a cord with an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
• Do not modify the plug provided with your dryer – if it doesn’t’t t the outlet, have a proper outlet installed by a qualied electrician.
• Do not connect the ground wire to plastic plumbing lines, gas lines, or hot water pipes.
Installation requirements
English 19
DV3200T_DC68-03784N-00_EN.indd 19 2020-05-25  11:10:19
Installation requirements
Electric models
WARNING
Your dryer has an optional cord with
Installation requirements
an equipment-grounding conductor and a grounding plug. This cord is sold separately.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with your dryer – if it doesn’t’t t the outlet, have a proper outlet installed by a qualied electrician.
If a power cord is not used and the electric dryer is to be permanently wired, the dryer must be connected to a permanently grounded metal wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer.
Electrical connections
Before operating or testing, follow all grounding instructions in the “Grounding” section. An individual branch (or separate) circuit serving only your dryer is recommended.
Do not use an extension cord.
Gas models – U.S. and Canada
A 120 volt, 60 Hz AC approved electrical service with a 15-ampere fuse or circuit breaker is required.
Electric models – U.S. only
Most U.S. dryers require a 120 / 240 volt, 60 Hz AC approved electrical service. Some require 120 / 208 volt, 60 Hz approved electrical service. The electric service requirements can be found on the data label located behind the door. A 30-ampere fuse or circuit breaker on both sides of the line is required.
If a power cord is used, the cord should be plugged into a 30-ampere receptacle.
The power cord is not provided with U.S. electric model dryers. This cord is sold separately.
English20
DV3200T_DC68-03784N-00_EN.indd 20 2020-05-25  11:10:19
WARNING
Risk of Electric Shock
When local codes allow, you can connect the dryer’s electrical supply with a new power supply cord kit, marked for use with a dryer, that is U.L. listed and rated at a minimum of 120 / 240 volts, 30-amperes with three No. 10 copper wire conductors terminated with closed loop terminals, open-end spade lugs with turned up ends, or with tinned leads.
• Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring must be supported at the dryer cabinet by a suitable UL-listed strain relief.
• Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. (Use a 4-prong plug for a 4 wire receptacle, NEMA type 14-30R.)
Electric models – Canada Only
A 120 / 240 volt, 60 Hz AC approved electrical service fused through a 30-ampere fuse or circuit breaker on both sides of the line is required.
NOTE
All Canadian models are shipped with the power cord attached. The power cord should be plugged into a 30-ampere receptacle. In Canada, you may convert a dryer to 120 / 208 volts.
Installation requirements
English 21
DV3200T_DC68-03784N-00_EN.indd 21 2020-05-25  11:10:19

Installation

This dryer must be installed by a qualied technician. The installer is responsible for connecting the dryer to the main power while observing the relevant safety regulations of your area.

What’s included

Make sure all the parts are included in the product package. If you have a problem with the dryer or the accessories, contact a local Samsung customer center or the retailer.
01
Installation
02
03
04
05
Dryer at a glance
01 Control panel 02 Worktop 03 Filter
04 Door 05 Exhaust duct
English22
DV3200T_DC68-03784N-00_EN.indd 22 2020-05-25  11:10:19
Accessories & tools
Required tools
Pliers Cutting knife Pipe wrench (gas
Nut driver
models only)
Level Philips screwdriver Duct tape Wrench
LPG-safe compound
or Teon Tape (for
gas installation)
WARNING
Packing materials can be dangerous to children. Keep all packing materials (plastic bags, polystyrene, etc.) out of children’s reach.
Installation
English 23
DV3200T_DC68-03784N-00_EN.indd 23 2020-05-25  11:10:20
Installation

Step-by-step installation

Make sure you have a qualied technician install the dryer. Step by step installation instructions start below.
Do not remove the protective lm on the door before completing the product installation. If you remove the protective lm before the installation is complete, the door may get scratched or damaged during installation.
Make sure the installation location allows enough space for the dryer door to be fully open.
Installation
STEP 1 Install the exhaust system
1. Select a location and move the dryer to the site. For easy access, we recommend you
2. To change the door direction, see “Switching the door position”.
3. Install the exhaust system as instructed in the “Exhaust ducting guide” section.
Before installing your dryer, remove the packing in the duct.
To move the dryer easily, lay two of the carton cushion-from the packaging on the
Secure room around the dryer to facilitate ducting and wiring.
STEP 2 Connect the gas line
Before connecting the gas line, make sure you have read the “Gas requirements” section on page 18.
1. Remove the protective cap from the gas pipe.
2. Apply a LPG (Liqueed Petroleum Gas)-safe compound or 1.5 wraps of Teon tape to
3. Connect the gas supply to the dryer. An additional tting is required to connect the
4. Turn on the gas supply, and check for any leaks using a soap solution. If a leak is found,
install the dryer in the same location as your washer.
CAUTION
NOTE
oor. Tip the dryer on its side so it lies across both cushion-tops. Push the dryer so that it is near its nal location, and then set the dryer upright.
all threaded connections.
3
/4” (1.9 cm) female thread end of a exible connector to the 3/8” (1 cm) male threaded end on the dryer. Tighten up the tting over all threads.
tighten the connections and try again. DO NOT use an open ame to check for gas leaks.
English24
DV3200T_DC68-03784N-00_EN.indd 24 2020-05-25  11:10:20
STEP 3 Connect the electrical wiring
First, read through the “Electrical requirements” section, and follow these steps. 3-wire system
1. Loosen or remove the screws from the center terminal block.
2. Connect the neutral wire (white or center wire) of the power cable to the center, silver-colored terminal screw of the terminal block. Tighten the screws.
3. Connect the other wires to outer
D
A
B C L2 L1
E
A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
3
/4” (1.9 cm) UL-listed strain relief
E.
terminal block screws. Tighten the screws.
4. Tighten the strain relief screws.
5. Insert the terminal block cover into the
rear panel of the dryer. Then, secure the cover with a hold-down screw.
CAUTION
To convert from the 4-wire system to 3-wire system, connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor.
Ring-type terminals are recommended. If using strap terminals, make sure they are tightened.
Before Installing the Dryer, conrm 240V is present between L1 and L2 at the power receptacle. If the Voltage is low, it may not dry properly. Review the “Electrical requirements” section on page 19 if needed.
Installation
English 25
DV3200T_DC68-03784N-00_EN.indd 25 2020-05-25  11:10:20
Installation
4-wire system
Installation
A. External ground connector
D. Neutral wire (white or center wire)
F
D
D
D
B C L2 L1
A
E
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
E
. 3/4” (1.9 cm) UL-listed strain relief
F. Neutral wire (white or center wire)
1. Remove the external ground connector’s screw, and connect the ground wire (green or unwrapped) of the power cable to the screw.
CAUTION
To connect the ground wire to the
neutral position without through contact A (cabinet ground), contact a technician. This is not user serviceable.
Ring-type terminals are remended. If
using strap terminals, make sure they are tightened.
2. Loosen or remove the screws from the center terminal block.
3. Connect the neutral wire (white or center wire) and ground wire (white) to the center screw of the terminal block. Tighten the screw.
4. Connect the other wires to the outer terminal block screws. Tighten the screws.
5. Tighten the strain relief screws.
6. Insert the tab of the terminal block cover
into the rear slot of the dryer. Secure the cover with a hold-down screw.
CAUTION
Before Installing the Dryer, conrm 240V is present between L1 and L2 at the power receptacle. If the Voltage is low, it may not dry properly. Review the “Electrical requirements” section on page 19 if needed.
WARNING
All U.S. models are designed for a 3-wire system connection. The dryer frame is grounded to the neutral conductor at the terminal block. A 4-wire system connection is required for new or remodeled construction, mobile homes, or if local codes do not permit grounding through neutral. If you use the 4-wire system, you cannot ground the dryer frame to the neutral conductor at the terminal block.
English26
DV3200T_DC68-03784N-00_EN.indd 26 2020-05-25  11:10:20
Remove the terminal block cover plate. Insert the power cord with a UL-listed strain
A
B
A B
relief through the hole provided in the cabinet near the terminal block.
A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure they are tight. Use a 3/8” (1 cm) deep well socket.
STEP 4 Level the dryer
To ensure optimal performance, the dryer must be level.
1. Using a level (A), check if the dryer is level side to side and then front to back. If the dryer is not level, adjust the leveling feet (B) at the bottom of the dryer. Then, check if the dryer is level again.
Installation
NOTE
To set the dryer to the same height
as your washer, fully retract (A) the leveling feet by turning them counterclockwise, then loosen (B) the feet by turning them clockwise. Once the dryer is the same height as the washer, follow the directions above to level the dryer.
Adjust the leveling feet only as much
as necessary to level the dryer. Extending the leveling feet more than necessary can cause the dryer to vibrate.
English 27
DV3200T_DC68-03784N-00_EN.indd 27 2020-05-25  11:10:20
Installation
STEP 5 Power on (Gas models)
Make sure all gas connections, the exhaust line, and all wiring is connected correctly. Then, plug the power cord into a power source and check the dryer’s installation and operation using the nal checklist in Step 7 below.
STEP 6 Final check
When installation is complete, conrm that:
The dryer is plugged into an electrical outlet and grounded properly.
The exhaust ductwork is connected and the joints are taped.
Installation
You have used rigid or stiff-walled exible metal duct material, not plastic exible duct.
The dryer is level and is sitting rmly on the oor.
The dryer starts, runs, heats, and shuts off properly.
For gas models:
The gas is supplied properly with no leaks.
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat setting will purge the line. If the gas does not ignite within 5 minutes, turn your dryer off and wait 5 minutes. Be sure the gas supply to your dryer has been turned on. To conrm gas ignition, check the exhaust for heat.
CAUTION

Vent blockage test

After the dryer is installed, start the Vent Blockage Test to check if the duct system is properly installed. The Vent Blockage Test automatically detects the status of the ducts and reports any blockage or problems. Proper ducting can reduce drying time and save energy.
NOTE
The Vent Blockage Test must run with the dryer in a cool state. If the dryer warms up after the installation check, run the AIR FLUFF cycle for several minutes to reduce its internal temperature.
Running the vent blockage test
1. Make sure the drum is empty, and then close the door.
(If there are any clothes or other items in the drum, the test will not give accurate results.)
English28
DV3200T_DC68-03784N-00_EN.indd 28 2020-05-25  11:10:20
2. Press the POWER button to turn the dryer on, then simultaneously press and hold the Time and START/PAUSE buttons for 3 seconds. “InS or In” appears in the dryer’s display.
(If you have started other procedures before the Vent Blockage Test, the dryer will not enter the Vent Blockage Test mode.)
3. Press the START/PAUSE button. The Vent Blockage Test starts immediately. During the test, the number indicator makes a circle in 6 clockwise steps. The test takes about 2 minutes. Do not open the door during the test.
4. After 2 minutes, when the test is complete, the results is displayed and the dryer sounds a tone. If status of the duct system is normal, “End or 0” appears and the dryer sounds a completion tone. If the duct system can not exhaust properly, check code appears and the dryer sounds an alarm tone. If there are any other problems, an information code appears in the display. For information about the code, see “Information codes” section on page 46.
To stop or cancel the Vent Blockage Test, press the POWER button to turn off your
dryer.
The results remain on the display for about 5 minutes and then automatically turn
off. You can turn the result off immediately by pressing the POWER button.
NOTE
During or after the test, the internal drum is hot. Use caution to prevent burns. The Vent Blockage Test is used to check for problems to the current duct system when the dryer is installed for the rst time.
If the test result displays check code (the duct system is blocked ), refer to the “Ducting requirements” section on page 15 and the “Exhaust ducting guide” section below, and then take proper measures to correct any problems. If the test is suspended, it could result in incorrect results. Follow the proper procedures when testing the dryer.
Even if the test result is normal (“End or 0”), the duct system could be blocked slightly. Properly install all duct work according to the installation instructions in this manual.
Installation
English 29
DV3200T_DC68-03784N-00_EN.indd 29 2020-05-25  11:10:20
Installation
Check code Meaning Solution
0 Vent condition is good. Clg (Cg) The vent is clogged.
C80 (C8)
C90 (C9)
Installation
Ct
tC Temperature sensor error Contact a service center.
About 80 % of the vent is clogged. (This may decrease the drying
performance.) Over 90 % of the vent is clogged.
(This may lead to poor drying performance or cause malfunction)
The internal temperature of the dryer is too low (below 32 °F (0 °C)) or too high (over 104 °F (40 °C)) and therefore vent blockage cannot be detected.
1. Clean the lint lter.
2. Check your vent condition.
(Refer to the “Ducting requirements” section)
* You must take measures (such as cleaning) through expert personnel.
Leave the dryer at room temperature (41~95 °F (5~35 °C)) for an hour and check again.
Unit is detecting items inside the
C1
dC Unit is detecting door is open
9C1 Abnormal voltage detected
drum or there is an error on the dry sensor.
Remove items from the drum and check again.
If the problem continues, contact a service center.
Close the door properly and check again.
If the problem continues, contact a service center.
Check the power connection. (Refer to the “Connect the electrical wiring” section)
If the problem continues, contact a service center.
English30