Samsung DV48H7400GW/A2-02, DV48H7400GW/A2-01, DV48H7400GW/A2-00, DV48H7400GP/A2-01, DV48H7400GP/A2-00 Owner’s Manual

...
DV48H7400E(G)* DV45H7400E(G)* DV45H7200E(G)* DV45H7000E(G)*
Gas and Electric Dryer
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
DV7000HA_DV48H_DC68-03170J-10_EN.indd 1DV7000HA_DV48H_DC68-03170J-10_EN.indd 1 5/16/2016 5:05:44 PM5/16/2016 5:05:44 PM
contents
OPERATING INSTRUCTIONS, TIPS
7
23
7 Basic requirments 8 Ducting requirements 9 Important to installer 9 Location considerations 9 Alcove or closet installation 10 Mobile home installation 10 Exhausting 11 Gas requirements 11 Commonwealth of Massachusetts
installation instructions
12 Electrical requirements 12 Grounding 13 Electrical connections 14 Installation - General procedure 17 Connecting the Inlet Hose (DV48(5)
H7400E(G)* ONLY)
17 Final installation check list 18 Dryer Exhaust Tips 19 Vent blockage test 20 Exhaust ducting guide 21 Door Reversal
23 Overview of the control panEL 26 Child lock 26 Drum Light (DV48(5)H7400E(G)*,
DV45H7200E(G)* ONLY)
26 SOUND 27 Smart Care (DV48(5)H7400E(G)*,
DV45H7200E(G)* ONLY)
28 Clean the lint fi lter 28 Load the dryer properly 28 Getting started
CARE AND CLEANING
29
SPECIAL LAUNDRY TIPS
29 Control Panel 29 Tumbler 29 Powder Coated Tumbler 29 Dryer Exterior 29 Dryer Exhaust System
30 Special laundry tips
30
TROUBLESHOOTING
31 Check these points if your dryer… 32 Information codes
31
APPENDIX
33
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec2:2DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec2:2 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
33 Fabric care chart 34 Protecting the environment 34 Declaration of conformity 34 Specifi cations 35 Cycle chart 36 Cycle chart 37 Cycle chart
English - 2
safety instructions
Congratulations on your new Samsung Dryer. This manual contains valuable information on the installation, use, and care of your appliance. Please take the time to read this manual to take full advantage of your dryer’s many benefi ts and features.
WHAT YOU NEED TO KNOW ABOUT SAFETY INSTRUCTIONS
Warnings and Important Safety Instructions in this manual do not cover all possible conditions and situations that may occur. It is your responsibility to use common sense, caution, and care when installing, maintaining, or operating your dryer.
Always contact your manufacturer about problems or conditions you do not understand.
IMPORTANT SAFETY SYMBOLS AND PRECAUTIONS
What the icons and signs in this user manual mean:
Hazards or unsafe practices that may result in severe personal injury or death.
Follow the information in this manual to minimize the risk of fi re or
WARNING
CAUTION
explosion or to prevent property damage, personal injury, or death. Do not store or use gasoline or other fl ammable vapors and liquids near
this or any other appliance.
Hazards or unsafe practices that may result in minor personal injury or property damage.
Do NOT attempt.
Do NOT disassemble.
Do NOT touch.
Follow directions explicitly.
Unplug the power plug from the wall socket.
Make sure the machine is grounded to prevent electric shock.
Call the service center for help.
Note
These warning icons are here to prevent injury to you and others. Please follow them explicitly. After reading this section, keep it in a safe place for future reference.
Read all instructions before using the appliance.
English - 3
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:3DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:3 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
safety instructions
WARNING: To reduce the risk of fi re, electric shock, or injury to persons when using your
WARNING
appliance, follow basic precautions, including the following:
1. Read all instructions before using this appliance.
2. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other fl ammable or explosive substances, as they give o vapors that could ignite or explode.
3. Do not use the dryer to dry clothes which have traces of any fl ammable substance, such as vegetable oil, cooking oil, machine oil, fl ammable chemicals, thinner, etc., or anything containing wax or chemicals, such as mops and cleaning cloths. Flammable substances may cause the fabric to catch fi re by itself.
4. Do not store or use gasoline or other fl ammable vapors and liquids near this or any other appliance.
5. Do not allow children to play on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
6. Before the appliance is removed from service or discarded, remove the door to the drying compartment.
7. Do not reach into the appliance if the drum is moving.
8. Do not install or store this appliance where it will be exposed to the weather.
9. Do not tamper with internal controls.
10. Do not repair or replace any part of the appliance or attempt any service unless specifi cally recommended in the user-maintenance instructions or in published user­repair instructions that you understand and have the skills to carry out.
11. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
12. Clean the lint screen before or after each load.
13. Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
14. Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
15. The interior of the appliance and exhaust duct should be cleaned periodically by qualifi ed service personnel.
16. Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fi re.
17. This appliance must be grounded. See “Electrical requirements” and ”Grounding” in installing your dryer section.
18. Do not allow children to play on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
19. Do not insert your hand under the dryer.
- This may result in injury.
20. Take care that children’s fi ngers are not caught in the door when closing it.
- This may result in injury.
21. Control board and inlet valve are intentionally not grounded and may present a risk of
electric shock only during servicing.
- Do not contact this part while appliance is energized.
English - 4
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:4DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:4 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
WARNING -
State of California Proposition 65 Warnings (US only)
Gas Appliances:
This product contains chemicals known to the State of California to cause
cancer and birth defects or other reproductive harm.
Gas appliances can cause low-level exposure to Proposition 65 listed
substances, including but not limited to, benzene, carbon monoxide, formaldehyde and soot, substances resulting from the incomplete combustion of natural gas or LP fuels.
WARNING - Risk of Fire
• Clothes dryer installation must be performed by a qualifi ed installer.
• Install the clothes dryer according to the manufacturer’s instructions and local codes.
Do not install a clothes dryer with fl exible plastic venting materials. If fl exible metal (foil type) duct is installed, it must be of a specifi c type identifi ed by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airfl ow and increase the risk of fi re.
• To reduce the risk of severe injury or death, follow all installation instructions.
To reduce the risk of fi re or explosion:
WARNING
Do not dry items that have been previously cleaned, washed, soaked, or spotted with
gasoline, dry cleaning solvents, or other fl ammable or explosive substances. They emit vapors that could ignite or explode. Any material that has been in contact with a cleaning solvent or fl ammable liquids or solids should not be placed in the dryer until all traces of these fl ammable liquids or solids and their fumes have been removed. There are many highly fl ammable items used in homes, such as acetone, denatured alcohol, gasoline, kerosene, some liquid household cleaners, some spot removers, turpentine, waxes, and wax removers.
Items containing foam rubber (may be labeled latex foam) or similarly textured rubber-
like materials must not be dried on a heat setting. Heated foam rubber materials can, under certain circumstances, produce fi re by spontaneous combustion.
What to do if you smell gas:
WARNING
• Do not try to light any appliance.
• Do not turn on the appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.
English - 5
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:5DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:5 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
safety instructions
Do not allow children or pets to play on, in, or in front of the appliance. Close supervision is necessary when the appliance is used near children and pets.
Before discarding or removing your dryer from service, remove the door to the drying compartment to prevent children or animals from becoming trapped inside.
Do not reach into the appliance when the drum is moving. Do not install or store this appliance where it will be exposed to the weather. Do not tamper with controls. Do not repair, replace, or attempt to service any part of the appliance unless specifi cally
instructed to in the user-repair instructions and you have the understanding and skills to carry out the procedure.
Do not use fabric softeners or products to eliminate static unless the softener or product is recommended for dryer use by the manufacturer of the fabric softener or product.
Clean the lint screen before or after each load. Keep the area around the exhaust opening and surrounding areas free from lint, dust, and dirt. The interior of the dryer and exhaust duct should be cleaned periodically by qualifi ed service
personnel. This appliance must be properly grounded. Never plug the power cord into a receptacle
that is not grounded adequately or not in accordance with local and national codes. See installation instructions for information about grounding this appliance.
Do not sit on top of the dryer. Ensure pockets are free from small, irregularly shaped hard objects, foreign material, etc. ie.
WARNING
coins, knives, pins, etc. These objects could damage your dryer. Do not wash clothing with large buckles, buttons, or other heavy metal or solid objects. Gas leaks may occur in your system, resulting in a dangerous situation.
WARNING
Gas leaks may not be detected by smell alone. Gas suppliers recommend you purchase and install a UL-approved gas detector. Install and use in accordance with the manufacturer’s instructions. Do not place items in your dryer that have been spotted or soaked with vegetable oil or cooking
oil. Even after being washed, these items may contain signifi cant amounts of these oils. Residual oil on clothing can ignite spontaneoulsy. The potential for spontaneous
combustion increases when items containing vegetable oil or cooking oil are exposed to heat. Heat sources such as your dryer can warm these items, allowing an oxidation reaction in the oil to occur. Oxidation creates heat. If this heat cannot escape, the items can become hot enough to catch fi re. Piling, stacking, or storing these kinds of items may prevent heat from escaping and can create a fi re hazard.
All washed and unwashed fabrics that contain vegetable oil or cooking oil can be dangerous. Washing these items in hot water with extra detergent will reduce, but not eliminate, the hazard. Always use the Cool Down cycle for these items to reduce their temperature. Never remove these items from the dryer hot or interrupt the drying cycle until the items have run through the Cool Down cycle. Never pile or stack these items when they are hot.
English - 6
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:6DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec11:6 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
installing your dryer
UNPACKING YOUR DRYER
Unpack your dryer and Inspect it for shipping damage. Make sure you have received all of the items shown below. If your dryer was damaged during shipping, or you do not have all of the items, contact 1-800-SAMSUNG (726-7864).
To prevent personal injury or strain, wear protective gloves whenever lifting or carrying the dryer.
Packing materials can be dangerous to children. Keep all packing material (plastic bags, polystyrene,
WARNING
etc.) well out of children’s reach. Do not move the product while holding the front part of the top cover of the dryer.
CAUTION
- This may cause the cover to be separated and result in injury.
01 installing your dryer
Control panel
Filter Frame Front
Tools needed
Pliers Cutting knife Pipe wrench (gas only) Nut drivers
Level Phillips Screwdriver Duct tape Wrench
Parts supplied (DV48(5)H7400E(G)* ONLY)
Top Cover
[ BACK ]
Door
Duct Exhaust
“Y”- Connector Hose water Short inlet hose
BASIC REQUIRMENTS
Make sure you have everything necessary for proper installation
A GROUNDED ELECTRICAL OUTLET is required. See Electrical Requirements.
A POWER CORD for electric dryers (except in Canada).
GAS LINES (if installing a gas dryer). The gas lines must meet national and local codes.
EXHAUST SYSTEM - must be rigid metal or fl exible sti -walled metal exhaust ducting.
English - 7
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:7DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:7 5/16/2016 5:05:49 PM5/16/2016 5:05:49 PM
installing your dryer
DUCTING REQUIREMENTS
Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
Do not use a smaller duct.
Ducts larger than 4 inches (10.2 cm) in diameter can cause increased lint accumulation.
Lint accumulation should be cleaned regularly.
If a fl exible metal duct must be used, use the type with a sti sheet metal wall. Do not use a fl exible duct
with a thin foil wall. Serious blockage can result if the fl exible metal duct is bent too sharply.
Never install any type of fl exible duct in walls, ceilings, or other concealed spaces.
Keep the exhaust duct as straight and short as possible.
Secure joints with duct tape. Do not use screws.
Plastic fl exible duct can kink, sag, be punctured, reduce airfl ow, extend drying times, and a ect dryer
operation.
Exhaust systems longer than recommended can extend drying times, a ect machine operation, and
may collect lint.
The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts and
the entry of wildlife. Never use an exhaust hood with a magnetic damper.
The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and
the ground or other obstruction. The hood opening should point down.
Never install a screen over the exhaust outlet.
To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a house
or porch.
If exhaust ductwork must run through an unheated area, the duct should be insulated and slope slightly
down towards the exhaust hood to reduce condensation and lint buildup.
Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord before
cleaning.
Check frequently to be sure the exhaust hood damper opens and closes freely.
Check once per month, and clean at least one time per year. Note: If clothes are not getting dry, then
check ducting for obstructions.
Do not exhaust dryer into any wall, ceiling, crawl space, or concealed space of a building, gas vent, or
any other common duct or chimney. This could create a fi re hazard from lint expelled by the dryer.
ELECTRIC AND GAS DRYER
Weather Hood Type
Recommended Use only for short-run installation
4” (10.2 cm) 2.5” (6.4 cm)
No. of 90° elbows Rigid Metallic Flexible* Rigid Metallic Flexible*
0 80 ft. (24.4 m) 41 ft. (12.4 m) 74 ft. (22.6 m) 33 ft. (10.1 m) 1 68 ft. (20.7 m) 37 ft. (11.2 m) 62 ft. (18.9 m) 29 ft. (8.8 m) 2 57 ft. (17.4 m) 33 ft. (10.1 m) 51 ft. (15.5 m) 25 ft. (7.6 m) 3 47 ft. (14.3 m) 29 ft. (8.8 m) 41 ft. (12.5 m) 21 ft. (6.5 m)
* Do not use non-metallic fl exible duct.
English - 8
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:8DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:8 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
If the new dryer is being installed into an existing exhaust system, you must make sure:
The exhaust system meets all local, state, and national codes.
That a fl exible plastic duct is not used.
To Inspect and clean all lint buildup from inside the existing duct.
The duct is not kinked or crushed.
The exhaust hood damper opens and closes freely.
The static pressure in any exhaust system must not exceed 0.83 inches of water column, or be less than 0.
This can be measured with the dryer running with a manometer at the point where the exhaust duct connects to the dryer. A no-heat setting should be used. The dryer tumbler should be empty and the lint fi lter clean.
IMPORTANT TO INSTALLER
Please read the following instructions carefully before installing the dryer. These instructions should be kept for future reference.
Remove the door from all discarded appliances to avoid the danger of a child su ocating.
WARNING
LOCATION CONSIDERATIONS
Locate the dryer where there is enough space at the front for loading the dryer, and enough space behind for the exhaust system. This dryer is factory-ready for rear exhaust. To exhaust out the bottom or the right or the left (electric model only), use the accessory exhaust kit (sold separately). Instructions are included with the kit. It’s important to make sure the room has enough fresh air. The dryer must be located where there is no air-fl ow obstruction.
On gas dryers, adequate clearance as noted on the data plate must be maintained to ensure adequate air for combustion and proper dryer operation.
Do not install or store the dryer in an area where it will be exposed to water and/or weather. Keep the dryer area clear of combustible materials, casoline, and other fl ammable vapors and liquids. A dryer produces combustible lint. The area around the dryer should be kept lint free.
01 installing your dryer
ALCOVE OR CLOSET INSTALLATION
You must exhaust the dryer to the outside to reduce the risk of fi re when you install the dryer in alcove or closet.
WARNING
No other fuel-burning appliance should be installed in the same closet as the dryer.
WARNING: To reduce the risk of fi re, you must exhaust the dryer to the outdoors.
See Exhaust information section.
Minimum clearances between the dryer and adjacent walls or other surfaces are:
2” in front, 17” on top, 1” on either side, and 5” in the back.
The closet front must have two unobstructed air openings for a combined minimum total area of 72 in²
with 3” minimum clearance on the top and bottom. A louvered door with equivalent space clearance is acceptable.
English - 9
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:9DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:9 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
installing your dryer
MOBILE HOME INSTALLATION
The installation of the dryer in mobile homes must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280 {formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the United States) or CSA Standards Z240 (for Canada).
When installing a dryer in a mobile home, you must make provisions for anchoring the dryer to the fl oor. Locate the dryer in an area that has adequate fresh air. A minimum of 72 in² (465 cm²) of unobstructed space is required. Call 1-800-SAMSUNG(726-7864) for information on purchasing the Floor Anchoring Kit as an accessory. All mobile home installations must be exhausted to the outside with the exhaust duct termination securely
fastened to the mobile home structure, using materials that will not support combustion. The exhaust duct may not terminate underneath the mobile home. See Exhausting section for more information.
EXHAUSTING
The dryer shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a concealed space of a building.
Exhausting the dryer to the outside will prevent large amount of lint and moisture from being blown into the room.
In the United States:
All dryers must be exhausted to the outside.
The required exhaust duct is 4 inches (10.2 cm) in diameter.
Use only those foil-type fl exible ducts, if any, specifi cally identifi ed for use with the appliance
by the manufacturer and that comply with the Outline for Clothes Dryer Transition Duct, Subject 2158A shall be used.
See “Ducting Requirements” in installing your dryer section for the maximum duct length and
number of bends shall be used.
The total length of fl exible metal duct shall not exceed 2.4 m.
Do not assemble the duct with screws or other fastening means that extend into the duct
and catch lint.
In Canada:
All dryer must be exhausted to the outside.
The exhaust duct should be 4 inches(10.2 cm ) in diameter.
Use only those foil-type fl exible ducts, if any, specifi cally indentifi ed for use with the appliance
by the manufacturer shall be used.
See “Ducting Requirements” in installing your dryer section for the maximum duct length and
number of bends.
The total length of fl exible metal duct shall not exceed 2.4 m.
Do not assemble the duct with screws or other fastening means that extend into the duct
and catch lint
Outside the U.S. and Canada:
Refer to the local codes.
You must exhaust the dryer to the outside to reduce the risk of fi re when you install the
WARNING
dryer in an alcove or closet. NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT. If your existing ductwork is plastic, non-metal, or combustible, replace it with metal. Use only a metal exhaust duct that is non-fl ammable to ensure containment of exhaust air, heat, and lint.
English - 10
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:10DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:10 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
GAS REQUIREMENTS
Use only natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE ANSI/Z223.1, LATEST REVISION (FOR THE UNITED STATES), OR WITH THE CAN/CGA-B149 INSTALLATION CODES (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural gas. If you plan to use your dryer with LP (liquid propane) gas, it must be converted for safe and proper performance by a qualifi ed service technician.
A 1/2” (1.27 cm) gas supply line is recommended and must be reduced to connect to the 3/8” (1 cm) gas line on your dryer. The National Fuel Gas Code requires that an accessible, approved manual gas shut-o valve be installed within 6” of your dryer.
Gas dryers installed in residential garages must be raised 18 inches (46 cm) above the fl oor.
Additionally, a 1/8” (0.3 cm) N.P.T. (National Pipe Thread) plugged tapping, accessible for test gauge connection, must be installed immediately upstream of your dryer’s gas supply connection.
Your dryer must be disconnected from the gas supply pipe system during any pressure testing of the system.
DO NOT reuse old fl exible metal gas lines. Flexible gas lines must be design certifi ed by the American Gas Association (CGA in Canada).
Any pipe joint compound used must be resistant to the action of any liquefi ed petroleum gas.
As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION – Your dryer uses an automatic ignition system to ignite the burner.
There is no constant burning pilot.
COMMONWEALTH OF MASSACHUSETTS INSTALLATION INSTRUCTIONS
Your dryer must be installed by a licensed plumber or gas fi tter. A “T” handle manual gas valve must be installed in the gas supply line to your dryer. If a fl exible gas connector is used to install your dryer, the connector can be no longer than 3’ (36”).
Gas leaks may occur in your system, creating a dangerous situation.
Gas leaks may not be detected by smell alone.
WARNING
Gas suppliers recommend you purchase and install a UL-approved gas detector.
Install and use in accordance with the manufacturer’s instructions.
01 installing your dryer
English - 11
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:11DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:11 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
installing your dryer
ELECTRICAL REQUIREMENTS
The Wiring diagram is located on the plate below the control panel or frame back.
Improperly connecting the equipment grounding conductor can result in a risk of electric shock.
WARNING
Check with a qualifi ed electrician or serviceman if you are in doubt as to whether your dryer is properly grounded. Do not modify the plug provided with your dryer – if it doesn’t fi t the outlet, have a proper outlet installed by a qualifi ed electrician.
To prevent unnecessary risk of fi re, electrical shock, or personal injury, all wiring and grounding
must be done in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes and ordinances. It is your responsibility to provide adequate electrical services for your dryer.
All gas installations must be done in accordance with the national Fuel Code ANSI/Z2231 – Latest
Revision (for the U.S.) or CAN/CGA – B149 Installation Codes – Latest Revision (for Canada) and local codes and ordinances.
GROUNDING
This dryer must be grounded. In the event of malfunction or breakdown, the ground will reduce the risk of electrical shock by providing a path of least resistance for the electrical current.
Gas models
WARNING
Your dryer has a cord with an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Do not modify the plug provided with your dryer – if it doesn’t fi t the outlet, have a proper outlet
installed by a qualifi ed electrician. Never connect the ground wire to plastic plumbing lines, gas lines, or hot water pipes.
Electric models
WARNING
Your dryer has an optional cord with an equipment-grounding conductor and a grounding plug, This cord is sold separately.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with your dryer – if it doesn’t fi t the outlet, have a proper outlet installed by a qualifi ed electrician.
If a power cord is not used and the electric dryer is to be permanently wired, the dryer must be connected to a permanently grounded metal wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer.
English - 12
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:12DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:12 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
ELECTRICAL CONNECTIONS
Before operating or testing, follow all grounding instructions in the Grounding section. An individual branch (or separate) circuit serving only your dryer is recommended. DO NOT USE AN
EXTENSION CORD.
Gas models – U.S. and Canada
A 120 volt, 60 Hz AC approved electrical service, with a 15-ampere fuse or circuit breaker is required.
Electric models – U.S. Only
Most U.S. dryers require a 120 / 240 volt, 60 Hz AC approved electrical service. Some require 120 / 208 volt, 60 Hz approved electrical service. The electric service requirements can be found on the data label located behind the door. A 30-ampere fuse or circuit breaker on both sides of the line is required.
If a power cord is used, the cord should be plugged into a 30-ampere receptacle.
The power cord is NOT provided with U.S. electric model dryers.
Risk of Electric Shock
WARNING
When local codes allow, the dryer electrical supply may be connected by means of a new power supply cord kit, marked for use with a dryer, that is U.L. listed and rated at a minimum of120/240 volts, 30-ampere with three No. 10 copper wire conductors terminated with closed loop terminals, open-end spade lugs with turned up ends, or with tinned leads.
Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring
must be supported at the dryer cabinet by a suitable UL-listed strain relief.
Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. (Use a 4-prong plug for a 4 wire receptacle, NEMA type 14-30R.)
Electric models – Canada Only
A 120 / 240 volt, 60 Hz AC approved electrical service fused through a 30-ampere fuse or
circuit breaker on both sides of the line is required.
All Canadian models are shipped with the power cord attached. The power cord should be
plugged into a 30-ampere receptacle.
It is not permissible to convert a dryer in Canada to 208 volts.
01 installing your dryer
English - 13
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:13DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:13 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
installing your dryer
INSTALLATION - GENERAL PROCEDURE
For proper installation, we recommend that you hire a qualifi ed installer.
Read these instructions completely before you begin the installation.
To install the dryer, follow these steps:
1. Move your dryer to an appropriate location for installation. Consider installing the dryer and washer side-
by-side so you have easy access to both appliances.
To move the dryer easily, lay two of the carton cushion-tops on the fl oor. Tip your dryer on its side so it lies across both cushion-tops. Push the dryer so that it is near its fi nal location. Set your dryer upright. Leave enough room around the dryer so you can attach the duct work, power cord, etc.
2. If you need to change the direction of the door, go to Door Reversal on page 19. When done, return to
Step 3 below.
3. Review the Exhausting section before installing the exhaust system. Install the duct work from your
dryer to the exhaust hood. The crimped end of the duct sections must point away from your dryer. DO NOT use sheet metal screws when assembling ducting. These joints should be taped. Never use plastic fl exible exhaust material.
A tip for tight installations: Attach a section of the exhaust system to your dryer before putting it in place. Use duct tape to secure this section to your dryer, but do not cover the ventilation slots at the back of the dryer cabinet.
4. If you have an electric model, skip to Step 6. If you have a gas model, go to the next step.
5. Review the Gas Requirements section, then follow the lettered steps below. a. Remove the pipe thread protective cap. b. Apply pipe joint compound or about 1 1/2 wraps of Tefl on tape over all threaded connections.
The pipe joint compound must be resistant to the action of any liquefi ed petroleum gas.
c. Connect the gas supply to your dryer. An additional fi tting is required to connect the 3/4” (1.9 cm)
female thread end of a fl exible connector to the 3/8” (1 cm) male threaded end on the dryer.
d. Securely tighten the gas line fi tting over the threads. e. Turn on the gas supply. Check all gas connections for leaks using a soap solution. If bubbles
appear, tighten the connections and recheck. DO NOT use an open fl ame to check for gas leaks.
f. Go to Step 6 on the next page
English - 14
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:14DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:14 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
6. Review the Electrical Requirements section, then follow the 3 Wire system connection instructions (Step
7) or 4 Wire system instructions (Step 8) below.
7. Three Wire system instructions: A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾” (1.9 cm) UL-listed strain relief
1. Loosen or remove the center terminal block screw.
2. Connect the neutral wire (white or center wire) of the power
cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten the strain relief screws.
5. Insert the tab of the terminal block cover into your Dryer’s rear panel slot.
Secure the cover with a hold-down screw.
If converting from a 4-wire electrical system to a 3-wire, you must connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor.
WARNING
We recommend using Ring terminals. If you use Strap terminals, please ensure you install them perfectly.
8. Four Wire System instructions: A. External ground connector B. Green or bare copper wire of power cord C. ¾” (1.9 cm) UL-listed strain relief D. Center silver-colored terminal block screw E. Neutral Grounding wire (white) F. Neutral wire (white or center wire)
1. Remove the External ground connector screw.
2. Connect the ground wire (green or unwrapped) of the
power cord to the external ground connector screw. If you want to connect B (Green or bare copper wire of power cord) to the Neutral Post without connecting it to A (cabinet ground), call a service technician.
3. Loosen or remove the center terminal block screw.
4. Connect the neutral wire (white or center wire) of the power cord and the appliance ground
wire (green with yellow stripes) under the central screw of the terminal block.
5. Connect the other wires to the outer terminal block screws. Tighten screws.
6. Tighten the strain relief screws.
7. Insert the tab of the terminal block cover into your Dryer’s rear panel slot.
Secure the cover with a hold-down screw.
We recommend using Ring terminals. If you use Strap terminals, please ensure you install them perfectly.
01 installing your dryer
English - 15
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:15DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:15 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
installing your dryer
U.S. MODELS:
Risk Of Electric Shock
WARNING
All U.S.models are designed for a 3-WIRE SYSTEM CONNECTION. The dryer frame is grounded to the neutral conductor at the terminal block. A 4-WIRE SYSTEM CONNECTION is required for new or remodeled construction, mobile homes, or if local codes do not permit grounding through neutral. If you use the 4-wire system, you cannot ground the dryer frame to the neutral conductor at the terminal block.
Remove the terminal block cover plate. Insert the power cord with a UL-listed strain relief through the hole provided in the cabinet near the terminal block.
A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure they are tight. Use a 3/8” (1cm) deep well socket.
9. To ensure that the dryer provides optimal drying performance, it must
be level. To level the dryer, follow the lettered steps below:
a. Using a level, check if the dryer is level side to side and then front
to back.
b. If the dryer is not level, adjust the leveling feet on the bottom of
the dryer until the dryer is level side to side and back to front. Turning the feet clockwise retracts the feet. Turning the feet clockwise loosens and extends them.
If you have a dryer and washer
To set the dryer to the same height as the washer, fully retract the leveling feet by turning them counterclockwise, then loosen the feet by turning them clockwise. Once the dryer is the same height as the washer, follow the directions above to level the dryer.
Level
Leveling feet
Retract fully Then loosen
Adjust the leveling feet only as much as necessary to level the dryer. Extending the leveling feet more than necessary can cause the dryer to vibrate.
10. Make sure all gas connections (on gas models) and exhaust, and electrical connections are complete.
Plug in your dryer, and then check its operation by using the checklist on the next page.
11. For GAS MODELS ONLY
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat setting will purge the line. If the gas does not ignite within 5 minutes, turn your dryer o and wait 5 minutes. Be sure the gas supply to your dryer has been turned on. To confi rm gas ignition, check the exhaust for heat.
English - 16
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:16DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:16 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
CONNECTING THE INLET HOSE (DV48(5)H7400E(G)* ONLY)
METHOD1
The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.
1. If space permits, attach the brass female end of the “Y” connector to the cold water faucet.
2. Turn the cold water faucet o .
3. Attach the straight end of long hose to “Y’ connector.
4. Using pliers, tighten the coupling with an additional two-thirds turn.
Do not overtighten, as it may damage the coupling.
5. Attach angled end of long hoses to fi ll the valve at the
bottom of the dryer’s rear frame. Screw on coupling by hand until it is seated on fi ll valve connector.
6. Using pliers, tighten the coupling with an additional two-thirds turn.
Do not overtighten, as it may damage the coupling.
7. Check that the water faucets are on.
8. Check for leaks around “Y” connector, faucets and hoses.
METHOD2
The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.
1. If “Y” connector cannot be attached directly to the cold water
faucet, the short hose must be used.
2. Turn the cold water faucet o .
3. Attach short inlet hose to cold water faucet.
Screw on coupling by hand until it is seated on the faucet.
4. Using pliers, tighten the coupling with an additional
two-thirds turn. Do not overtighten, as it may damage the coupling.
5. Attach ‘Y” connector to brass male end of small hose.
Screw on coupling by hand until it is seated on connector.
6. Using pliers, tighten the coupling with an additional two-thirds turn.
Do not overtighten, as it may damage the coupling.
7. Attach angled end of long hoses to the fi ll valve at the bottom of the dryer rear frame. Screw on
coupling by hand until it is seated on fi ll valve connector.
8. Using pliers, tighten the coupling with an additional two-thirds turn.
Do not overtighten, as it may damage the coupling.
9. Check that the water faucets are on.
10. Check for leaks around “Y” connector, faucets and hoses.
01 installing your dryer
FINAL INSTALLATION CHECK LIST
The dryer is plugged into an electrical outlet and grounded properly.The exhaust ductwork is hooked up and the joints are taped.You have used rigid or sti -walled fl exible metal duct material, not plastic fl exible duct.The dryer is level and is sitting fi rmly on the fl oor.For gas models: The gas is turned on and there are no gas leaks.Start your dryer to confi rm that it runs, heats, and shuts o .
English - 17
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:17DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:17 5/16/2016 5:05:50 PM5/16/2016 5:05:50 PM
installing your dryer
DRYER EXHAUST TIPS
Plastic or non-metal fl exible duct presents a potential fi re hazard.
WARNING
1. Make sure your dryer is installed properly so it exhausts air
easily.
2. Use 4” diameter rigid metal duct. Tape all joints, including at
the dryer. Never use lint-trapping screws.
3. Keep ducts as straight as possible.
4. Clean all old ducts before installing your new dryer.
Be sure the vent fl ap opens and closes freely. Inspect and clean the exhaust system annually.
Don’t let a poor exhaust system slow drying by:
1. Restricting your dryer with a poor exhaust system.
2. Using a plastic, thin foil, or non-metal fl exible duct.
3. Using unnecessarily long ducts that have many
elbows.
4. Using crushed or clogged venting or ducts.
1 2
Dryer
DUCT
Wall
DUCT EXHAUST
TAPE
3 4
English - 18
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:18DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:18 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
VENT BLOCKAGE TEST
After the dryer is installed, start the Vent Blockage Test to check if the duct system is properly installed. The Vent Blockage Test automatically detects the status of the ducts and reports any blockage or problems. Proper ducting can reduce drying time and save energy.
The Vent Blockage Test must run with the dryer in a cool state. If the dryer warms up after the installation check, run the AIR FLUFF cycle for several minutes to reduce its internal temperature.
Running the vent blockage test
1. Make sure the drum is empty, and then close the door.
(If there are any clothes or other items in the drum, the test will not give accurate results.)
2. Press the POWER button to turn the dryer on, then simultaneously press and hold the Adjust Time
display. (If you have started other procedures before the Vent Blockage Test, the dryer will not enter the Vent Blockage Test mode.)
3. Press the START/PAUSE button. The Vent Blockage Test starts immediately. During the test, the number indicator makes a circle in 6 clockwise steps. The test takes about 2 minutes. Do not open the door during the test.
4. After 2 minutes, when the test is complete, the results is displayed and the dryer sounds a tone. If status of the duct system is normal, “End or 0” appears and the dryer sounds a completion tone. If the duct system can not exhaust properly, “CLg or Cg” appears and the dryer sounds an alarm tone. If there are any other problems, an information code appears in the display. For information about the code, see “Information codes” section on page 32.
• To stop or cancel the Vent Blockage Test, press the POWER button to turn o your
dryer.
• During the test, if “dE” appears in the display, make sure the door is closed. If “C1” is
displayed, see if there is laundry inside drum. If there is, stop the test and remove it. Then, start the test again.
• The results remain on the display for about 5 minutes and then automatically turn o . You
can turn the result o immediately by pressing the POWER button.
• During or after the test, the internal drum is hot. Use caution to prevent burns. The Vent Blockage Test is used to check for problems to the current duct system when the dryer is installed for the fi rst time.
• If the test result displays “CLg or Cg” (the duct system is blocked ), refer to the “Ducting requirements” section on page 8 and the “Exhaust ducting guide” section below, and then take proper measures to correct any problems. If the test is suspended, it could result in incorrect results. Follow the proper procedures when testing the dryer.
• Even if the test result is normal (“End or 0”), the duct system could be blocked slightly. Properly install all duct work according to the installation instructions in this manual.
and Dry level buttons for 3 seconds. “InS or In” appears in the dryer’s
01 installing your dryer
English - 19
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:19DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:19 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
EXHAUST DUCTING GUIDE
Ducting
1. Make sure the dryer is installed properly so the air exhausts freely.
2. Use 4-inch rigid metal ducts. Tape all joints including the dryer connection.
Never use lint-trapping screws.
3. To facilitate the exhaust, keep the ducts as straight as possible.
Cleaning
Clean all old ducts before installing the dryer, and make sure the vent fl ap opens and closes freely. We recommend that you clean the exhaust system annually or on a regular basis.
• To prevent fi re, do not use plastic, thin-foil, or non-metal fl exible ducts of any kind.
WARNING
• Do not use a poor exhaust system because it slows down the dryer’s performance.
• Do not use excessively long ducts that have multiple elbows.
• Do not use crushed or clogged venting or ducts.
English - 20
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:20DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:20 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
DOOR REVERSAL
If you want to reverse the direction of the door, it is recommended calling a qualifi ed service technician.
1. Unplug the power cord.
2. Remove the four hinge screws from the door
3. Remove the door by lifting it
4. Remove the two screws from the holder-lever, and then remove
the cover-holder.
5. Assemble the holder-lever on the opposite side using the screws
that were removed from the holder-lever-in Step 4.
6. Assemble the cover-holder on the opposite side.
7. Remove the two cover-hinges.
8. Assemble the two cover-hinges
on the opposite side.
Use a fl at head screwdriver(-) to remove the cover-holder’s cover-hinge.
01 installing your dryer
9. Remove the 14 screws.
Two screw (L) are longer than the other screws.
L
English - 21
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:21DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:21 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
installing your dryer
10. Remove the holder-glass.
11. Exchange the positions of:
: The cover-hinge and handle door : The holder-hinge and guider-
holder glass
12. Remove the Lever-Door, Cover-
Lever (DV45H7000E(G)* Only) and then install it on the opposite side. : DV48(5)H7400E(G)*/ DV45H7200E(G)* Refer Figure. 1 : DV45H7000E(G)* Refer Figure. 2
Refer to the illustrations on the right to aid you in the assembly process.
13. Remove the cover-hole (P).
14. Assemble the holder glass and then fasten the 14 screws
that you removed in step 9.
15. Attach the cover-hole.
Fig 2
Fig 1
L
P
16. Install the door on the frame-front and then fasten the
4screws that you removed in step 2.
Check the positions of the screws you installed in the hinge door.
English - 22
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:22DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec3:22 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
operating instructions, tips
To reduce the risk of fi re, electric shock, or injury to persons, read the IMPORTANT SAFETY
WARNING
INSTRUCTIONS before operating this appliance.
OVERVIEW OF THE CONTROL PANEL
DV48(5)H7400E(G)*
3 4 5 76
1 8
DV45H7200E(G)*
DV45H7000E(G)*
2
02 operating instructions, tips
To select a cycle, rotate the Cycle Selector dial to the desired cycle. The indicator light by the cycle name will illuminate. The NORMAL, PERM
PRESS, HEAVY DUTY, BEDDING, SANITIZE, DELICATES, AND TOWELS (DV48(5)H7400E(G)*, DV45H7200E(G)*) cycles are Sensor Dry cycles. Sensor Dry automatically senses the moisture in the load and shuts the dryer
Cycle Selector
1
o when the load reaches the dryness level you have selected with the Dry Level Selection Button (see below).
NORMAL – Use this cycle to dry loads of cotton, underwear, and linen. HEAVY DUTY – Use this cycle to dry heavy fabrics such as jeans, corduroys,
or work clothes with high temperature heat. BEDDING For bulky items such as blankets, sheets and comforters.
English - 23
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:23DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:23 5/16/2016 5:05:51 PM5/16/2016 5:05:51 PM
operating instructions, tips
SANITIZE Sanitizes garments by infusing high temperature heat deep into the fabric during the drying cycle. Use this cycle to keep your bedding and curtains clean through sanitization.
DELICATES The Delicates cycle is designed to dry heat-sensitive items at a low drying temperature.
TOWELS (DV48(5)H7400E(G)*, DV45H7200E(G)*) – To dry bath towels and similar items.
PERM PRESS Dry wrinkle-free cottons, synthetic fabrics, knits, and permanent press fabrics automatically.
QUICK DRY – Provides a 30 minute drying cycle. TIME DRY – Time Dry allows you to select the desired cycle time in minutes.
Turn the Cycle Selector dial to Time Dry, and then press the Adjust Time up arrow to set the drying time. Press the arrow repeatedly to scroll through the time settings.
REFRESH (DV48(5)H7400E(G)*) – Use to smooth out wrinkles and reduce odors in loads of one to four items. In this cycle a small amount of water is sprayed into the dryer drum after several minutes of tumbling with heat. Confi rm that the laundry load is dry.
AIR FLUFF (DV45H7200E(G)*) The Air Flu cycle tumbles the load at room temperature air.
WRINKLE AWAY (DV48(5)H7400E(G)*) – Removes wrinkles from clothes stored in closets, etc. It provides wrinkle release via optimized steam care.
For best results, load 2-3 items at once. You can extend the drying time by a minimum of 20 minutes , depending on the item type or load. Confi rm that the laundry load is dry.
WRINKLE RELEASE (DV45H7200E(G)* / DV45H7000E(G)* ) The Wrinkle Release cycle will release wrinkles from items that are clean, dry, and only slightly wrinkled, such as clothes from a crowded closet, suitcase or items that have been in the dryer too long after the cycle has ended. Wrinkle Release can be used with any temperature selection.
The display window shows the estimated time remaining in the cycle after you have pressed the Start/Pause button. The estimated time remaining may fl uctuates as the cycle progresses.
The Drying light will illuminate and remain lit until the cycle is complete.
Digital Graphic
2
Display
Dry Level
3
Selection Button
Temp Selection
4
Button
When your dryer is in the cool-down phase, the Cooling light will illuminate. When your dryer is in the wrinkle prevent phase, the Wrinkle Prevent light will illuminate.
When the cycle is complete, “End” (DV48(5)H7400E(G)* / DV45H7200E(G)*) / “0” (DV45H7000E(G)* will appear in the display panel until you push
the Start/Pause button or the Power button. If your dryer is paused during a cycle, the indicator lights will blink until you press
the Start/Pause button. To select the dry level in the Normal, Heavy Duty, or other Sensor Dry cycles,
press the Dry Level button. An indicator light will illuminate next to the dryness level you selected.
Press the button repeatedly to scroll through the settings. Larger or bulkier loads may require the Very Dry or More Dry setting for complete dryness.
Damp Dry is designed to partially dry items. Use for items that lay fl at or hang to dry.
To select the temperature for the load, press the Temp button. An indicator light will illuminate next to the temperature you selected. Press the button repeatedly to scroll through the settings.
High – For sturdy cottons or those labeled Tumble Dry. Medium – For permanent press, synthetics, lightweight cottons, or items
labeled Tumble Dry Medium.
Low – For heat sensitive items labeled Tumble Dry Low or Tumble Dry Warm. Extra Low (DV48(5)H7400E(G)*, DV45H7200E(G)*) – Provides the lowest
heated drying temperature possible.
English - 24
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:24DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:24 5/16/2016 5:05:52 PM5/16/2016 5:05:52 PM
Time Selection
5
Button
Select Cycle
6
Option
Start/Pause
7
selection button
Power button
8
When using Manual Dry cycles, you can adjust the drying time by pressing the time selection button.
During the Sensory Dry cycle, the time light indicator is o because exact drying times are determined by fl uctuating humidity levels.
Therefore, the actual drying time may di er from the displayed time. Adjust Time You can add or subtract time from the automatically set times
in the Manual Dry cycles (Quick Dry, Time Dry, Air Flu (DV45H7200E(G)*), Wrinkle Release cycles or Wrinkle Away (DV48(5)H7400E(G)*) cycle.
To add or subtract time from the cycle, press the Adjust Time arrow pad up or down until the desired time is displayed.
Wrinkle Prevent Wrinkle Prevent provides approximately 180 minutes of intermittent tumbling in unheated air at the end of the cycle to reduce wrinkling. Press the Wrinkle Prevent button to activate this feature.
The indicator light above the pad will illuminate when you select Wrinkle Prevent. The load is dry and you can remove it at any time during the Wrinkle Prevent cycle. Mixed Load Bell The mixed load bell that notifi es you when the average
dry level in a load is damp dry (80 % dried). This lets you take garments that you don’t want fully dried or that dry quickly out of the dryer early while letting others continue to dry. You can select this function in all Sensor Dry cycles except Sanitize. The dry level selections are limited to Normal Dry, More Dry, and Very Dry.
Smart Care (DV48(5)H7400E(G)*, DV45H7200E(G)*) – Use this function to check if the Dryer is out of order using your smart phone when the Dryer malfunctions. This function is set if you press and hold the Mixed Load Bell key for 3 seconds.
Press to pause and restart programs.
Press once to turn your dryer on, Press again to turn it o . If you turn your dryer on and do not touch any buttons for 10 minutes, the power automatically turns o .
02 operating instructions, tips
If you insert laundry into your dryer while it is extremely tangled immediately after your washer has fi nished a wash or spin cycle, it may degrade the drying e ciency or cause the door to open. We recommend that you disentangle your laundry appropriately before inserting it.
Each indicator on the graphic display means:
Filter Check
Child Lock On/O
Sound On /O
Drum Light On/O
Steam
English - 25
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:25DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:25 5/16/2016 5:05:52 PM5/16/2016 5:05:52 PM
operating instructions, tips
CHILD LOCK
Prevents children from playing with your dryer.
Setting/Releasing
If you want to set or release the Child Lock, press the Temp. and Time buttons simultaneously for 3 seconds.
Child Lock Details
- You can turn Child Lock on while your dryer is running.
- Once you turn Child Lock on, no button, except for the Power button, will respond until you
turn o the Child Lock function.
- The Child Lock indicator will be lit.
If you have not turned o Child Lock, and then turned the dryer o and on, the Child Lock function will still be on. To turn o Child Lock, follow the instructions above.
When other buttons, except for the Power button, do not respond, check the Child Lock indicator. If Child Lock is on, follow the instructions above to turn Child Lock o .
DRUM LIGHT (DV48(5)H7400E(G)*, DV45H7200E(G)* ONLY)
Lights the dryer drum while the dryer is running.
Turning On and O
Press and hold the Wrinkle Prevent button for 3 seconds or more.
You can turn the Drum Light on and o while your dryer is running and when it is stopped. If you do not turn the Drum Light o 5 minutes after turning it on, the Drum Light automatically turns o .
SOUND
The Sound O function can be selected during all courses.
Activating
If you want to activate the Sound O function, press the Dry Level button at the same time for 3 seconds. The “ ” will be lit when this feature is activated.
Deactivating
If you want to deactivate the Sound O function, press the Dry Level button at the same time for 3 seconds again.
When this function is selected, sound is turned o for all courses. Even if the power is turned on and o repeatedly, the setting is retained.
English - 26
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:26DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:26 5/16/2016 5:05:52 PM5/16/2016 5:05:52 PM
SMART CARE (DV48(5)H7400E(G)*, DV45H7200E(G)* ONLY)
This function enables you to check the status of the dryer using a smartphone.
1. To enable the Smart Care function, press the power button to turn the dryer on and then press and hold
the Mixed Load Bell button for 3 seconds. If you press a button other than the Mixed Load Bell button after turning the dryer on, you will not be able to activate the Smart Care function.
The error code history is deleted after using the function.
2. If the Smart Care function is activated, the Smart Care indicator is lit on the display.
3. Run the Smart Care app on your smart phone.
GalaxyS, GalaxyS2, GalaxyS3, GalaxyS4, GalaxyS2(HD), Galaxy Note, Galaxy Note2,
Galaxy Note3 (Other devices may not be normal operation). Supported operating system: Android 2.2 or higher.
IPhone 3 G S, iPhone 4/4S, iPhone 5/5S. Supported operating system : OS 4.3 or higher.
4. Focus the smart phone’s camera on the display panel of the Dryer.
5. If the smart phone’s camera is focused on the display panel of the Dryer, the panel and error message is
automatically recognized and the error type and countermeasures are displayed on the smart phone.
6. If the smartphone fails to recognize the error code more than twice, please enter the error code
displayed on the display panel of the dryer manually into the Smart Care app.
Downloading the Smart Care app
Download the Samsung Laundry App into your mobile phone from the Android market or Apple
App store. (Search word : Samsung Smart Washer/Dryer)
Precautions when using Smart Care
If light from a light bulb, fl uorescent bulb, or lamp is refl ected on the display panel of the dryer, the
smartphone may not be able to recognize the panel or error message easily.
If you hold the smartphone at too large an angle relative to the front of the display panel, it may not
be able to recognize the error code. For best results, hold the smartphone so that the front of the panel and the smartphone are parallel or nearly parallel.
02 operating instructions, tips
English - 27
DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:27DV7000HA_DV48H_DC68-03170J-10_EN.indd Sec6:27 5/16/2016 5:05:52 PM5/16/2016 5:05:52 PM
Loading...
+ 61 hidden pages