SAMSUNG DIGIMAX A402 SERVICE INFORMATION strobe defect

Service Information
S/I NO.
DATE MAY. 10. 2005
MODEL A302, A402
SUBJECT
1. Phenomenon
doesn't work.
-. Sometimes, flash doesn't work and the taken image is over or under exposure.
-. Flash doesn't work after strobe comes out a lot.
2. Solution
-. Defect of strobe has been related to Q2 on the Shutter Board.
-. If Q2 has been destroyed, change it and reinforce the trigger line.
1) Remove the R11 at the top of Shutter board and connect C1 GND with Q2 at the
bottom of Shutter board with Lead wire.
2)Change R13 : 10R
05CG58001
Strobe defect
→→→→
47R, C4 : 0.01uF->0.02uF
<Move to the next page to see working position>
3. etc.
-. After changing parts, update the Firmware 0520
FLASH PCB TOP
FLASH PCB BOTTOM
<Working position>
(
Í)
Á¦
R11 » è
Remove R11
Q2 Bat GND 불안(
RemoveR11toreinforcetheQ2Trigger
삭제
line, and then, connect the lead wire C1
GND. Change R13
Battery GND 보강
10->47ohmÀ¸·Î º¹±
R13
원거/라인폭)으로
결선용
L/W
from 10R to 47R
R11
하단
Hand-made L/W
C4:0.01-> 0.02uF
C4 0.01uF->0.02uF