Samsung b25, S25, B24, S26, S27 Block Diagram

...
3
1
1
17. Disassembly of PCB panel and Assembly of internal components
116
17-1) Unplug the refrigerator
17-2) Detach the cover of PCB panel using driver
17-3) Assembled state of PCB pane
115
16-1) Remove screws of the cover of the machine room at the bottom side of the back of the refrigerator
16-2) Assembled state of Machine Room
117
18. Installation of the water dispenser line
1) For automatic operation of the ice maker, water pressure of 1.4~4.5Kg
f/
is required.(It is
acceptable if the disposable paper cup(177cc) can be filled up with water within a second.)
2) The water tube can be used by cutting to the desired length. Make sure that the tube is not
bent.
3) Make the maximum length of the water tube to be 12m, if possible. If the length is over 12m,
it will cause a problem to supply water because of decrease of water pressure.
4) Locate the water tube at the area without heat.
5) The purifier is just for filtration. It will not work as sterilizer of microorganisms.
6) If the refrigerator is installed in the area with low water pressure(below 1.4 Kg
f/
),
additionally purchased booster pump may be installed in order to compensate the shortage
of pressure.
7) The life cycle of purifier depends upon the condition of the usage, but we recommend that
you change it every 6 months. So we recommend to install it at an eccess place for changing.
8) To supply water to the storage tank inside the refrigerator, press the cold water button for
about 2 or 3 minutes and make cold water drop from the cold water outlet.
9) In order to avid possible leakage, seal every joined area using sealing tape.
10) The water tube should be commected to the cold tap water.
Check the components
1. Connect couplers and valve to the water pipe.
1) Close the main water valve.
2) Connect the coupler ÒAÓ to the tap water valve.
3) Connect the coupler ÒAÓ and ÒBÓ to the water pipe.
4) Every joint should be taped with sealing tape.(see the picture)
5) If there is only one water pipe, connect coupler ÒAÓ
If the coupler A and B doesnÕt fit to the existing water pipe, consult the closest authorized service dealer and purchase the right couplers for the proper installation.
2. Connect the water tube to water tube valve
1) Insert the nut into the water tube
2) Insert the water tube into the water tube valve as shown in the picture on the right side.
3) Tighten the nut by turning it.
The water tube should be connected to the cold water pipe. If it is connected to the hol water pipe, it may cause some problems in the Functioning of the purcher.
PRECATUTION!
6. Fix the purifier.
1) Fix the purifier as shown int he picture on the right.
3. Select the purifier location for installation
1) Cut the water tube, attached to the purifier, to the proper length after measuring the distance from the location of the purifier to the water tube valve.
2) If you want to reassemble the water inlet side and outlet side of the purifier during the installation of the purifier, see the reference picture.
4. Remove the residuals inside the purifies.
1) Open the main water valve to check whether water is running through the water tube from the water inlet side of the purifier.
2) If water doesnÕt come out through the tube, turn the water tube valve.
3) Leave the faucet open until clean water is running out.
4) It is no problem with the residuals because it might be left while manufactruing the filter.
5. Fix the purifier lock station.
1) Hold the purifier lock station against the lock hole of right­lower side in the back of the refrigerator and fix it tightly using screw.
7. Connect the water tube to the refrigerator.
1) Remove the back cover of the refrigerator.
2) Connect the water tube to the valve through the hole in the back cover as shown in the picture.(The connector is lockated at right side of the machine room in the back of the refrigerator.)
3) When connected, check whether there is any leakage. On leakage, reassemble them.
8. Put the water tube in order
1) Using the clip ÒAÓ and ÒBÓ fix the water tube to the wall.
2) When the water tube is put in order, make sure there are any forced bending and pushing against the water tube.
CLIP A
CLIP B
WATER TUBE
9. Complete the installation of the water dispenser line
1) Turn on the refrigerator and press the left side lever until water is coming out through the water tube.(approximately 2~3minute) (Press it until the initial air outing phenomenon disappear.)
2) At this time, check any possible leakage on the joints of the water tube. After putting the water tube in order, move the refrigerator to the desired location. Once the refrigerator is located, do not move the refrigerator as possible.
118
10. Check the amount of supplied water to the ice maker.
1) Remove the upper ice maker frome the refrigerator.
The Method to control the amount of water supply to the ice maker
1. Disassemble the PCB panel at the top of he refrigerator.
3. If S/W control is completed, check the amount of supplied water to the Ice Maker.
4. If the amount of water supply is not enough, reset the S/W. (Read item 2 and 3). If the setting is completed in accordance with water pressure in the pipe, reassemble the PCB panel.
2. Using the water controlling S/W, control the amount of water supply.
Option to control water-supply time
2) When the test button is pressed, the ice cube container is tured and then water is out from the tap of the ice maker where water is wupplied. At this time, check the amount of water.(see the picture) If there is over-supply of water, the ice cube will be made in attached form of 2 to 4 ice cubes, If there is less-supply of water, the ice cube will be made in small size. When this happens, you may encounter inconvenience while using. This is not a problem in the refrigerator. It is the problem of water pressure in the water pipe and occurs frequrently. When this problem occurs, control the amount of water supply by the following method.
S/W1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S/W2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
S/W3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
SR-S24FTA
6 Seconds
5 Seconds
7 Seconds
8 Seconds
9 Seconds
12 Seconds
15 Seconds
23 Seconds
SWITCH NO MODEL NAME
After change of the water-supply time, the power switch of the refrigerator must be turned off and then turned on again. (Otherwise, the change will not work.) When the refrigerator is marketed, the water-supply time is set to 6 seconds. The amount of water supply depends upon the set time and the water pressure(water pressure for home use). If th ice cube is small, it may be caused by less supply of water. So, increase the water­supply time(for example : change the time from 6 seconds to 7 seconds). If ice cubes are attached each other because of over-supply of water, decrease the water-supply time(for example : change the time from 6 seconds to 5 seconds).
If the controlled amount of water supply is slightly below the optimum level, it doesnÕt matter for use.
Notice
When setting the amount of water supply, do not select the large amount of water supply from the beginning. Set step-by-step. (Water can be over flowed)
120
19-2) PCB ASSÕY Component List
Basic Model(SR-S24NTA)
NO
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
EA
1
1
1
2
1
1
2
(4)
2
9
1
1
1
1
1
1
1
1
26
1
1
1
1
1
1
1
1
1
ITEMS
MICOM
VOLTAGE REGULATOR
VOLTAGE REGULATOR
IC-LINER
LED-DRIVER
IC-RESET
TRASNISTOR
DIODE-SWITCHING
DIODE-ZENER
DIODE-RECT
RESONATOR-CERAMIC
SWITCH-TACT
HEAT-SINK
FUSE
HOLDER-FUSE
BUZZER
COIL-CHOKE
SCREW
WIRE-SO-COPPER
CONNECTOR WAFER
CONNECTOR WAFER
CONNECTOR WAFER
CONNECTOR WAFER
CONNECTOR WAFER
CONNECTOR WAFER
CONNECTOR WAFER
C-ELECTRIC
C-ELECTRIC
Specification
TMP87C840N-4796
KA7812
KA7805
ULN2003A
uP2981C
KA7533
KSR1005
1N4148
UZ5.1B
IN4007
4.00MHz
SKHV-109105A
AL6063
250V 500mA
FH-51H 7.5A
BM-20K
75mH 10
2S-3 8
P10.6
SMW250-02 WHT
SMW250-06 BLU
SMW250-06 WHT
SMW250-07 WHT
SMW250-11 WHT
YW396-09AV WHT
YW396-09AV RED
220 /35V
1000 /35V
SUPPLIER
TOSHIBA
SAMSUNG SEMICONDUCTOR
SAMSUNG SEMICONDUCTOR
ALLEGRO, T1
NEC, ALLEGRO
SAMSUNG SEMICONDUCTOR
SAMSUNG SEMICONDUCTOR
PYUNGCHANG
PYUNGCHANG
PYUNGCHANG
MURATA
KYUNGIN
SINDANG
SMAJU
YONHO
BUJUN
BUJUN
DAEJUNG
WONGONG
YONHO
YONHO
YONHO
YONHO
YONHO
YONHO
YONHO
SAMHWA
SAMHWA
CODE-NO
DA09-30015A
1202-000243
1003-000274
1003-000217
1003-000217
1201-000001
A4068-0008
0402-000127
0403-000005
0402-000137
2802-000159
3404-000282
DA62-30103A
3601-000284
A3064-0021
3002-001019
DA75-10001A
6002-000463
DA75-90001A
3711-000797
3711-001036
3711-001038
3711-001082
3711-000616
3711-000357
3711-003383
2401-000725
2401-000187
REMARK
NO
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
EA
2
11
1
3
4
11
1
4
2
19
5
2
5
2
1
1
1
1
ITEMS
C-ELECTRIC
C-ELECTRIC
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-METAL FILM
CR-NETWORK
RELAY
RELAY
RELAY
PCB
CONNECTOR WAFER
CONNECTOR WAFER
VARISTOR
Specification
470 /25V
104
47 -J(1/4)
220 -J(1/4)
47K -J(1/4)
1K -J(1/4)
2.2K -J(1/4)
4.7K -J(1/4)
6.8K -J(1/4)
10K -F(1/4)
10K -J(1/4)
250V 104 121
JQ 1a-12V OR
JZ 1aFS-12V
(Both Used)
VSB-12TB
FR-1 T1.6
YM396-07AV WHITE
SM250-02 BLUE
SVC 471D-14A
SUPPLIER
SAMWHA
DONGYANG
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
KUMKANG
MATSUSHITA
MATSUSHITA
TAKAMISAWA
CHUNGJU
YONHO
YONHO
SAMWHA CONDENSER
CODE-NO
2401-001401
2202-000780
2001-000023
2001-000034
2001-000076
2001-000042
2001-000047
2001-000055
2001-000060
2001-000065
2004-000216
2011-000875
3501-000399
3501-000301
3501-000274
DA41-10119A
3711-000315
3711-000795
1405-000186
REMARK
121
Additional components(to the basic type) : on the model with Ice Dispenser(SR-S24FTA)
NO
46
47
48
49
50
51
52
53
54
55
NO
01
03
04
06
07
08
09
10
11
12
13
EA
7
3
4
2
1
1
1
2
1
(3)
ITEMS
C-ELECTRIC
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-METAL FILM
CONNECTOR WAFER
RELAY
DIP S/W(Regulation
of water supply)
DIODE-SWITCHING
Specification
104
47K -J(1/4)
1.0K -J(1/4)
10K -J(1/4)
12K -J(1/4)
10K -J(1/4)
SMW250-08 WHT
JQ1a-12V OR
JZ1a-FS12V(Both used)
DJDI-04TL
1N4148
SUPPLIER
DONGYANG
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
ABCO, HANRUK
YONHO
MATSUSHITA
JEIL
PYUNGCHANG
CODE-NO
2002-000780
2001-000055
2001-000042
2001-000065
2001-000068
2004-000216
3711-001084
3501-000399
3501-000301
3407-000222
0402-000127
REMARK
ÒDeleted components(from the Basic type) : 5 Wire-So-Copper
(Jump Wire at the position of C901~C905)Ó
19-3) Service Components list of Circuit
Code No.
DA41-20153D
DA41-20153E
DA41-10118E
DA41-10118D
DA26-30111A
DA26-30111B
DA26-30111C
DA32-10104F
DA32-10104G
DA32-10105F
DA32-10105L
DA32-10105K
DA41-20152A
DA41-20147A
DA41-20148A
Specification
SR-S24NTA
SR-S24FTA
SR-S24NTA
SR-S24FTA
AC220V/50,60Hz
AC150V/50,60Hz
AC240V/50,60Hz
502AT(430mm)
502AT(650mm)
502AT(250mm)
502AT(640mm)
502AT(200mm)
220V/50,60Hz
240V/50,60Hz
105V/50,60Hz
EA
1
1
1
1
1
1
1
1
1
1
1
1
1
Remark
Basic
Basic ICE & WATER DIP
Basic
Basic ICE & WATER DIP
Items
MAIN PCB ASSÕY
PANEL PCB ASSÕY
DC-TRANS
DC-TRANS
DC-TRANS
F-ROOM-SENSOR
R-ROOM-SENSOR
AMBIENT-SENSOR
F-EVA-SENSOR
R-EVA-SENSOR
INVERTER PCB
INVERTER PCB
INVERTER PCB
Loading...