Samsung AWT24F1ME7, AWT19F1MEB User Manual

E A
DB68-01198A(10)
OWNER’S INSTRUCTIONS
WINDOW-TYPE
ROOM AIR CONDITIONER
( Cool )
AWT18F1ME AWT20F1MB AWT24F1MB
AWT24F1ME
AWT18F1MBB/BC
AWT20F1MBA AWT24F1MBA/BC AWT18F1MEA/EB/EC
AWT19F1MEA AWT24F1MEB/EC

Safety Precautions

The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their own
discretion. Instead, they are requested to directly contact a designated
service
center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main switch
off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off the
breaker used for your air conditioner and contact your installation specialist. Make sure that the unit is correctly ventilated at all times: Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7 meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. Can cause injury or death. Disconnect all remote
electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar qualified
person in order to avoid a hazard.
E-2
D
ISPOSING OF THE UNIT
OTHERS
The air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring,earthing and safety regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less than 3.5mm. Such means for disconnection must be incorporation in the fixed wiring.
Before throwing out the device, it is necessary to pull back the battery cells and get
When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectl injur
Please recycle or dispose of the packaging material for this product in an environmentally
Never store or ship the air conditioner upside down or sideways to avoid damage to
The appliance is not intended for use by young children or infirm persons without supervision: with
Max current is measured according to IEC standard for safety and current is measured
rid of them safely for recycling reasons.
y, refrigerant may blow out and come into contact with your skin,causing
y. Releasing refrigerant into the atmosphere also damages the environments.
responsible manner.
the compressor.
Young children should be supervised to ensure that they do not play
the appliance.
according to ISO standard for energy efficiency.
E-3
Contents
PREPARING
YOUR AIR CONDITIONER
Safety Precautions ......................................................................................... 2
Air Conditioning Unit - Main Parts and Control Panel .................................... 4
Getting Started ............................................................................................... 5
OPERATING YOUR AIR CONDITIONER
Cooling Your Room ........................................................................................ 6
Airing Your Room ........................................................................................... 7
Switching the Air Conditioner Off .................................................................... 7
Adjusting the Air Flow Direction Horizontally .................................................. 8
Adjusting the Air Flow Direction Vertically ...................................................... 8
RECOMMENDATIONS FOR USE
Operating Recommendation ........................................................................... 9
Temperature and Humidity Ranges ................................................................ 9
Cleaning Your Air Conditioner ........................................................................ 10
Solving Common Problems ............................................................................ 11
Technical Specifications ................................................................................. 11
METHOD OF INSTALLATION ................................................................................. 12

Air Conditioning Unit - Main Parts and Control Panel

E-4
Ventilation lever
Outer air flow blades (up/down orientation)
Inner air flow blades (right/left orientation)
Air inlet (Outside)
Power Cable
Power cable connection
should be committed to an installation engineer.
BLUE BROWN
YELLOW/GREEN
Main Power Earth
Air inlet(Inside)
Air filter(Inside)
The design and shape are subject to
change, depending on the model.
Temperature control dial
Cooling lamp
Operating
mode
selection dial
Air flow blade swing switch

Getting Started

E-5
You have just purchased a window-type room air conditioner and it has been installed by your installation specialist.
Your Owner’s Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s features.
The booklet is organized as follows.
The illustration on page 4 shows the air conditioning unit;
it indicates the location and purpose of the main parts and controls on the unit.
In the main part of the document, you will find a series of step-by-step
procedures for each function available.
The illustrations in the step-by-step procedures use four different symbols:
PRESS PUSH IMPORTANT NOTE
Loading...
+ 11 hidden pages