OWNER’S
INSTRUCTIONS
AWT12P1HEA AWT12P1HBA
AWT18P1HBA/BB AWT18U1HBA/BB
AWT18P1HEA/EB AWT18U1HEA/EB
AWT24P1HBA/BB AWT24U1HBA/BB
AWT24P1HEA/EB/EC AWT24U1HEA/EB/EC
Window-type Room Air Conditioner
( Cool )
E
A
DB98-17027A(4)
E-
2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their
own
discretion. Instead, they are requested to directly contact a designated
service center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the
breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7
meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. • Can cause injury or death. • Disconnect all
remote
electric power supplies before servicing, installing or cleaning.
• This must be done by the manufacturer or its service agent or a similar
qualified
person in order to avoid a hazard.
D
ISPOSING OF THE UNIT
OTHERS
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Before throwing out the device, it is necessary to pull back the battery cells and
get
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectl
injury. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally
Never store or ship the air conditioner upside down or sideways to avoid damage
to
The appliance is not intended for use by young children or infirm persons without
supervision:
with the appliance.
Max current is measured according to IEC standard for safety and current is
measured
rid of them safely for recycling reasons.
y, refrigerant may blow out and come into contact with your skin,causing
responsible manner.
the compressor.
Young children should be supervised to ensure that they do not play
according to ISO standard for energy efficiency.
Contents
◆ PREPARING
■ Safety Precautions ......................................................................................... 2
■ Air Conditioning Unit - Main Parts and Control Panel .................................... 4
■ Getting Started ............................................................................................... 5
PERATING YOUR AIR CONDITIONER
◆ O
■ Cooling Your Room ........................................................................................ 6
■ Airing Your Room ........................................................................................... 7
■ Switching the Air Conditioner Off .................................................................... 7
■ Adjusting the Air Flow Direction Horizontally .................................................. 8
■ Adjusting the Air Flow Direction Vertically ...................................................... 8
YOUR AIR CONDITIONER
◆ RECOMMENDATIONS FOR USE
■ Operating Recommendation ........................................................................... 9
■ Temperature and Humidity Ranges ................................................................ 9
■ Cleaning Your Air Conditioner ........................................................................ 10
■ Solving Common Problems ............................................................................ 11
■ Technical Specifications ................................................................................. 12
◆ METHOD OF INSTALLATION ................................................................................. 13
E-3
Air Conditioning Unit - Main Parts and Control Panel
The design and shape are subject to change,
depending on the model.
Air inlet(Inside)
Inner air flow blades
(right/left
orientation)
Outer air flow blades
(up/down
orientation)
Air filter(Inside)
AWT12*****
Power plug
type of the power
(The
plug
may differ according
the type of local power
to
y.)
suppl
AWT12***** AWT18*****
AWT24*****
AWT18*****
AWT24*****
BLUE BROWN
Main Power Earth
Air inlet (Outside)
Ventilation lever
Power Cable
YELLOW/GREEN
Power cable connection
should
an
be committed to
installation engineer.
Cooling lamp
E-
4
Operating mode
selection
dial
Temperature
control
Med
Cool
Air flow blade swing switch
dial
Operating mode
selection
dial
Air flow blade swing switch
Temperature
dial
control
Getting Started
You have just purchased a window-type room air conditioner and it has been installed
by your installation specialist.
Your Owner’s Instructions contain much valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit’s features.
The booklet is organized as follows.
◆ The illustration on page 4 shows the air conditioning unit;
it indicates the location and purpose of the main parts and controls on the unit.
◆ In the manual, you will find a series of step-by-step
procedures for each function available.
The illustrations in the step-by-step procedures use four different symbols:
☛
PRESS PUSH IMPORTANT NOTE
➢