Samsung AWH126 Operating Instructions

3. Installation and Operating Instructions
3-1 Installation
When selecting the area for installing the unit, be sure to obtain approval of the customer.
*
1. Make sure that you install the unit in an area that provides good ventilation.
The air conditioner must not be blocked by any obstacle affecting the air flow near the air inlet and air outlet.
3. Make sure that you install the unit away from heat or vapor.
4. Make sure that you install the unit in an area where the cooled air can be evenly spread in a room.
5. Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances. (obtain a clearance of at least one meter)
Caution:
7. Make sure that you install the unit in an area not exposed to rain or direct sunlight. (Install a separate sunblind if exposed to direct sun-
light.)
8. Do not install the unit in an area subjected to noise or vibration amplification which may affect your neighbor. (Fix the unit firmly if mounted in a high place.)
Do not use the air conditioner in such areas as a greasy area(including machine oil), saline area(sea side), or sulphuric area(hot spring). When using the air conditioner in these areas, special maintenance is required. Contact your local dealer or our service center for advice.
Samsung Electronics 3-1
3-2 Function Description
FANCOOLHEATDEICE
POWER / MODE
°C
Hour
Remote control sensor
Deice indicator
Operating mode indicator
Temperature/Timer settings
Temperature indicator Timer indicator
POWER/MODE button
3-2-1 Cooling operation mode
The compressor is turned on and off according to the ambient temperature and set temperature.
1. Compressor on and off control ¥ Compressor on and off control according to the ambient temperature.
The compressor is turned off when "ambient temperature = set temperature -1ûC"
*
The compressor is turned on when "ambient temperature = set temperature +1ûC"
*
2. Default value after power reset set temperature = 18ûC
FAN SPEED = HIGH
3. Set temperature indicating (setting) range : 1ûC interval from 18ûC to 30ûC.
3-2-2 Heating operation mode
The compressor is turned on and off according to the ambient temperature and set temperature.
1. Compressor on and off control. ¥ Compressor on and off control according to the ambient temperature.
The compressor is turned off when "ambient temperature = set temperature +1ûC"
*
The compressor is turned on when "ambient temperature = set temperature -1ûC"
*
2. Default value after power reset set temperature = 24ûC
FAN SPEED = HIGH
3. Set temperature indicating (setting) range : 1ûC interval from 16ûC to 30ûC.
3-2-3 Fan operation mode
1. If "Fan operation mode" signal is received from remocon.
the compressor is immediately turned off and only fan motor is operated at set blowing speed.it changes such as "HIGH → LOW HIGH"( if Fan speed is selected).
2. The initial FAN speed is set to "HIGH".
3. The set temperature can not be indicated and set.
3-2 Samsung Electronics
3-2-4 LED lamp and LED display indication in case of error detection
ERROR OPERATION
ROOM THERMISTOR
(OPEN OR SHORT)
INDOOR PIPE THERMISTOR
(OPEN OR SHORT)
OUTDOOR PIPE THERMISTOR
(OPEN OR SHORT)
LED LAMP DISPLAY
COOL HEAT FAN
7-SEG
LED DISPLAY
E1 displayed E5 displayed
E6 displayed
Lamp blinking at every second (on for 0.5s and off for 0.5s)
LED lamp off
1. Set operation in case of error occurrence. ¥ Malfunction of each temperature sensor (open, short)
- Error mode display, warning sound.
- The operation status is off.
2. The "outdoor pipe thermistor" error mode carry out checking only during heating operation and
do not carry out checking during "COOLING" and "FAN" operation.
3-2-5 Panel key operation
Key discription
Key name
Power/Mode 1. Operation mode change and POWER OFF(in case of model option heat pump) TACT
at every ON
*
- Selected as "OFF –> COOL –> HEAT –> FAN –> OFF". (Default=OFF) Continuous operation is not available.
*
Key operational function Key Type
Samsung Electronics 3-3
3-2-6 LED lamp operation specifications
LAMP name Operations specifications
COOL The mode is set to "COOL" –> ON
Others –> OFF
HEAT The mode is set to "HEAT" –> ON
Others –> OFF
FAN The mode is set to "FAN" –> ON
Others –> OFF
ûC The set temperature is displayed or set -> ON
Others –> OFF
HR During setting of the convenient reserve (OFF TIMER) time -> blinking
After setting of the convenient reserve (OFF TIMER) time -> ON Others –> OFF
DEICE Till the "DEICING" operation is completed during heating opertion -> ON
Others –> OFF
In case of (set) temperature display
-> NO. (1) 7 seg. LED display indicates temperature of the tens digit (ûC, ûF)
-> NO. (2) 7 seg. LED display indicates temperature of the units digit (ûC, ûF) In case of time (OFF TIMER) display
(1) (2)
-> NO. (1) 7 seg. LED display indicates time of the tens digit
-> NO. (2) 7 seg. LED display indicates time of the units digit
3-4 Samsung Electronics