ROOM AIR CONDITIONER
AWH120JE/123JE
Manual
SERVICE
AIR CONDITIONER CONTENTS
1. Precautions
2. Product Specifications
3. Installation and Operating
Instructions
4. Disassembly and Reassembly
5. Troubleshooting
6. Exploded Views and Parts List
7. Block Diagram
8. Wiring Diagram
Samsung Electronics Co., Ltd. MAR. 1998.
©
Printed in Korea.
Code No. DB81-10151A(1)
1. Precautions
1. Warning: Prior to repair, disconnect the
power cord from the circuit breaker.
2. Use proper parts: Use only exact
replacement parts. (Also, we recommend
replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools
and test equipment, and know how to use
equipment may cause problems laterintermittent contact, for example.
4. Power Cord: Prior to repair, check the
power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid
tapping into a power cord. This practice
may result in malfunction or fire.
6. After completing repairs and reassembly,
check the insulation resistance, Procedure:
Prior to applying power, measure the
resistance between the power cord and the
ground terminal. The resistance must be
greater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions
are satisfactory. Relocate the unit if
necessary.
9. Keep children away from the unit while it is
being repaired.
10. Be sure to clean the unit and its surrounding
area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics 1-1
2. Product Specifications
2-1 Table
Item
T ype
Dimensions:
X Height X Depth)
(Width
Packing Size
(Width X Height X Depth)
Voltage:
Phase
Frequency
Operating Current
Power Consumption
Refrigerant Type
Refrigerant Charge
Cooling Capacity
EER
Net Weight
Condenser
Condenser Fan
Evaporator
Evaporator Fan
Fan Motor
Compressor(Rotary)
Overload Protect
Compressor Capacitor
Fan Motor Capacitor
Fan Speed Control
Thermo Control
Unit of Measure
-
mm
mm
Volt
-
Hz
A
W
FREON
g
BTU/h
BTU/h.W
kg
Row
Type
Row
Type
W
Model
µF/ VAC
µF/ VAC
-
-
AWH120JE/123JE(COOL/HEAT)
Window
600
X 394 X 555
X 441 X 638
699
220 ~ 240
Single
50
5.9 / 5.3
1,350 /1,210
R-22
680
11,500 / 11,500
8.5 / 9.5
45
X 14
2
Propeller Fan
X 14
2
Blower
AMAFS100ATEA
48H124JV1E4
MRA12030-12008
30 / 450
3.5 / 450
Fan speed switch (High & Low)
Thermostat
DUAL TYPE
Remarks
Samsung Electronics 2-1