1. Precautions
1. Warning: Prior to repair, disconnect the power cord from the circuit breaker.
2. Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools and test equipment, and know how to use equipment may cause problems later­intermittent contact, for example.
4. Power Cord: Prior to repair, check the power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.
6. After completing repairs and reassembly, check the insulation resistance, Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9. Keep children away from the unit while it is being repaired.
10. Be sure to clean the unit and its surrounding area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics 1-1
2. Product Specifications
2-1 Table
Item
T ype Dimensions:
X Height X Depth)
(Width Packing Size
(Width X Height X Depth) Voltage:
Phase Frequency Operating Current Power Consumption Refrigerant Type Refrigerant Charge Cooling Capacity EER Net Weight Condenser Condenser Fan Evaporator Evaporator Fan Fan Motor Compressor(Rotary) Overload Protect Compressor Capacitor Fan Motor Capacitor Fan Speed Control Thermo Control
Unit of Measure
-
mm
mm
Volt
-
Hz
A
W
FREON
g
BTU/h
BTU/h.W
kg Row Type Row Type
W
Model
­µF/ VAC µF/ VAC
-
-
AWH120JE/123JE(COOL/HEAT)
Window
600
X 394 X 555
X 441 X 638
699
220 ~ 240
Single
50
5.9 / 5.3
1,350 /1,210
R-22
680
11,500 / 11,500
8.5 / 9.5 45
X 14
2
Propeller Fan
X 14
2
Blower
AMAFS100ATEA
48H124JV1E4
MRA12030-12008
30 / 450
3.5 / 450
Fan speed switch (High & Low)
Thermostat
DUAL TYPE
Remarks
Samsung Electronics 2-1