SAMSUNG AW240WB0K_CAP.31002.1.15 Service Manual

ROOM AIR CONDITIONER
TIMER
FAN SPEED
AIR SWING
CONT.
OFF
hour
THERMOSTAT
A W-1407B A W-1807B A W-1817B A W-1808E A W240WB0K
SERVICE
Manual
CONTENTSROOM AIR CONDITIONER
1. Precautions
2. Product Specifications
4. Disassembly and Reassembly
5. Troubleshooting
6. Exploded Views and Parts List
7. Block Diagram
8. Wiring Diagram
ELECTRONICS
¤ˇSamsung Electronics Co., Ltd. JAN. 1998.
Printed in Korea. Code No. DB81-10098A(4)
1. Precautions
1. Warning: Prior to repair, disconnect the power cord from the circuit breaker.
2. Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools and test equipment, and know how to use equipment may cause problems later­intermittent contact, for example.
4. Power Cord: Prior to repair, check the power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.
6. After completing repairs and reassembly, check the insulation resistance, Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9. Keep children away from the unit while it is being repaired.
10. Be sure to clean the unit and its surrounding area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
1-1Samsung Electronics
2. Product Specifications
2-1 Table
Item
Type Dimensions: Width¡¿Height¡¿Depth Packing Size Width¡¿Height¡¿Depth Voltage: Phase Frequency Operating Current Power Consumption Refrigerant Type Refrigerant Charge Cooling Capacity EER Net Weight Condenser Condenser Fan Evaporator Evaporator Fan Fan Motor Compressor(Rotary) Overload Protect Compressor Capacitor Fan Motor Capacitor Fan Speed Control Thermo Control Timer Control
Unit of Measure
-
mm
mm
Volt
-
Hz
A
W
FREON
g
BTU/h
BTU/h.W
kg Row Type Row type
W
Model
-
§ / VAC
§ / VAC
-
-
hour
AW-1407B
220 208 ~ 230
6.7
1,400
810
14,000
10.0 54
2¡¿16
2¡¿14
IC-13635SWF6B
48A135IV1E1
MRA12002-9200
25/450
(DUAL)
6/450
AW-1807B
AW-1817B
Window
660¡¿420¡¿695
737¡¿476¡¿794
Single
60 50
9.2
2,000
9.1 / 10.1 2,045
R-22
820
18,000
9.0
1,200
18,000
8.8
55
Propeller Fan
Blower
IC-13640SWF6B
48B190IV2E7
MRA12016-12007
40/450
(DUAL) (DUAL) (DUAL) (DUAL)
6/450
IC-13640SWF6B
48B175IV1E7
MRA12016-12007
35/450 6/450
Fan speed switch(High & Low)
Thermostat
12
AW-1808E
220~240
8.7
2,000
1,140
18,000
9.0 58
3¡¿16
3¡¿14
IC-13435SWJ5A
IC-13640SWF6B
48B180JV1E7
MRA12016-12007
MRA12068-12007 40/450 6/450
AW240WB
220
60
10.7
2,290
1,200
22,000
9.6
48B220IV1E7
40/450 6/450
2-1Samsung Electronics
2-2 Dimensions
660
420
420
695
Unit : mm
Front view
Side view
Samsung Electronics2-2
3. Installation and Operating Instructions
3-1 Installation
¡ When selecting the area for installing the unit, be sure to obtain approval of the customer.
1. Make sure that you install the unit in an area that provides good ventilation. The air conditioner must not be blocked by any obstacle affecting the air flow near the air inlet and air outlet.
2. Make sure that you install the unit in an area which can endure the weight and vibration of the unit.
3. Make sure that you install the unit away from heat or vapor.
4. Make sure that you install the unit in an area where the cooled air can be evenly spread in a room.
5. Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances.(obtain a clearance of at least one meter)
CCaauuttiioonn
Do not use the air conditioner in such areas as a greasy area(including machine oil), saline area(sea side), or sulphuric area(hot spring). When using the air conditioner in these areas, special maintenance is required. Contact your local dealer or our service center for advice.
:
6. Make sure that you install the unit in an area which provides easy drainage for condensed water.
7. Make sure that you install the unit in an area not exposed to rain or direct sunlight. (Install a separate sunblind if exposed to direct sunlight.)
8. Do not install the unit in an area subjected to noise or vibration amplification which may affect your neighbor. (Fix the unit firmly if mounted in a high place.)
3-1Samsung Electronics
TIMER
FAN SPEED
AIR SWING
CONT.
OFF
hour
THERMOSTAT
3-2 Operating Instruction
Thermostat control
Air swing switch
Timer control
Fan speed switch
3-2-1 Thermostat control
Off :
When the room temperature is lowered by the air conditioner, the gas within the thermostat will contract and cause a break in the electric contact. The compressor will then stop. After the compressor stops, the room temperature will rise.
On :
As the room temperature increases to a selected level, the gas within the thermostat expands, causing electric contact, which provides the source of electric power to the compressor. The room temperature will fall, and the cycle will repeat.
Control Operation :
By turning the control knob clockwise(toward higher numbers), the temperatures will be cooler. By turning the control knob counterclockwise(toward lower numbers), the temperature will be warmer.
Level 1 : Cool air will be supplied above 30~35¡ .
Cool air will be ceased below 28~32.5¡ .
Level 10 : Cool air will be supplied above 17.4~20.4¡ .
Cool air will be ceased below 14.4~17.4¡ .
Samsung Electronics3-2
Loading...
+ 15 hidden pages