HS
I
L
G
NE
Window-type Room Air Conditioner (Cool)
L
O
Ñ
A
P
SES
I
AÇNARF
DB98-26003A
OWNER'S
INSTRUCTIO
NS
E S F P I
SÊUGU
T
R
O
PO
N
AILAT
I
DB98-20384A.indd 23 2006-4-4 16:22:45
AW07P1H Series
AW09P1H Series
AW12P1H Series
AWT12P1H Series
AW14P1H Series
AW18P1H Series
AWT18P1H Series
AW24P1H Series
AWT24P1H Series
AW122PM
E-2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their
own
discretion. Instead, they are requested to directly contact a designated
service
center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch
off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the
breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7
meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. • Can cause injury or death. • Disconnect all
remote
electric power supplies before servicing, installing or cleaning.
• This must be done by the manufacturer or its service agent or a similar
qualified
person in order to avoid a hazard.
AQ07S2GE IB_E_15110 04/2/2 15:35 Page 2
Register your product at www.samsung.com/global/register
D
ISPOSING OF THE UNIT
OTHERS
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Before throwing out the device, it is necessary to pull back the battery cells and
rid of them safely for recycling reasons.
get
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectl
injur
Please recycle or dispose of the packaging material for this product in an
environmentally
Never store or ship the air conditioner upside down or sideways to avoid damage
to
The appliance is not intended for use by young children or infirm persons without
supervision:
with
Max current is measured according to IEC standard for safety and current is
measured
y, refrigerant may blow out and come into contact with your skin,causing
y. Releasing refrigerant into the atmosphere also damages the environments.
responsible manner.
the compressor.
Young children should be supervised to ensure that they do not play
the appliance.
according to ISO standard for energy efficiency.
Contents
CCCCAAAAUUUUTTTTIIIIOOOONN
NN
PREPARING YOUR AIR CONDITIONER
Safety Precautions
Air Conditioning Unit-Main Parts and Control Panel
OPERATION YOUR AIR CONDITIONER
CoolingYour Room
Ai
ring Your Room
Switching the Air Conditioner
Adjusting the Air F
Adjusting the Air F
l
ow Direction Horizontally
l
ow Direction Vertically
RECOMMENDATIONS FOR USE
Temperature and Humidity Ranges
n
Cleani
Solving Common Pr
I
NSTALLATION
g Your Air Conditioner
o
blems
O
ff
HSILGNE
2
4
5
6
6
7
7
7
8
9
10
The illustrations in the step-by-step procedures use four dif ferent symbols:
"The high inrush current of the starting compressor motor can have adverse effects to
e
the op
ration of other equipment under unfavorable mains conditions.This equipment
does not comply with the re
fluctuations and fl
Be
fore connection this equipment to the power supply system, please report to your
suply auth
Do not connect other elec
AW18
**
The max
Usual
branch to the power outlet is fed from a junction box with a rated current of 32A.
i
mum permissible system impedance at the power junction box is 0.24 ohms.
l
y, the maximum permissible mains impedance will not be exceeded when the
i
cker."
o
rity and obtain the consent.
l
evant technical standards for the limitation of voltage
t
ric appliances to the same supply lines.
E-3
E-4
Air Conditioning Unit - Main Parts and Control Panel
The desing and shape are subject to
change according to the model.
Power plug
The type of the
p
ower plug
may differ according to the
type of local power supply.
Inner air f
low blades
(right/left orientation)
Outer air f
l
ow blades
(up/down orientation)
Air inlet (Outsid
e
)
Ventilation lever
Power Cable
Air inlet(Insid
e
)
The air filter
i
s
located in side
Operating mode
selection dial
Temperature
control dial
Air f
low blade swing switch
Air Outlet
Coolest