7. Block Diagram
7-1 Refrigerating Cycle Block Diagram
Capillay tube
T1 |
Check V/V |
Heat exchanger (Evaporator)
fan
T2
Heat |
fan |
|
Propeller |
||
exchanger |
||
|
||
(Condenser) |
|
4-way valve
Cooling
Compressor |
Heating |
|
Samsung Electronics |
7-1 |
7-2 Basic Structure
7-2-1 Micom Control Diagram
|
MICOM |
|
|
|
|
LED CONTROL |
|
|
|
• Mode(COOL, FAN) |
|
|
|
• Temperature Display |
|
Room Temperature Sensor |
A/D converter |
• Temp |
|
• HR |
|||
Receiving Unit of Remocon |
|
||
|
|
||
|
Remocon Single Receiving |
|
|
Remote Cotrol |
|
|
|
FAN SPEED(HIGH,LOW) |
|
Compressor |
|
• Air swing motor control |
|
||
|
|
||
TEMP. SETTING(▼▲) |
• Compressor control |
Fan motor |
|
TIMER SETTING(▼▲) |
• Buzzer control |
Air swing motor |
|
|
|||
|
• Temperature control |
|
|
COOL |
|
Power circuit (DC 5V) |
|
|
|
||
FAN |
|
Power circuit (DC 12V) |
|
|
|
||
ON/OFF |
Reset Circuit |
Down Trans (AC13V ~ AC17V) |
|
|
|
||
AIR SWING |
Oscillation Circuit |
|
|
|
|
Power input (AC198V ~ AC264V) |
7-2 |
Samsung Electronics |