3. Installation and Operating Instructions
3-1 Installation
* When selecting the area for installing the unit, be sure to obtain approval of the customer.
1.Make sure that you install the unit in an area that provides good ventilation.
The air conditioner must not be blocked by any obstacle affecting the air flow near the air inlet and air outlet.
2.Make sure that you install the unit in an area which can endure the weight and vibration of the unit.
3.Make sure that you install the unit away from heat or vapor.
4.Make sure that you install the unit in an area where the cooled air can be evenly spread in a room.
5.Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances.
(obtain a clearance of at least one meter)
6.Make sure that you install the unit in an area which provides easy drainage for condensed water.
7.Make sure that you install the unit in an area not exposed to rain or direct sunlight.
(Install a separate sunblind if exposed to direct sunlight.)
8.Do not install the unit in an area subjected to noise or vibration amplification which may affect your neighbor.
(Fix the unit firmly if mounted in a high place.)
Caution:
Do not use the air conditioner in such areas as a greasy area(including machine oil),
saline area(sea side), or sulphuric area(hot spring). When using the air conditioner in these areas, special maintenance is required. Contact your local dealer or our service center for advice.
Samsung Electronics |
3-1 |
3-2 Function Description
Remote control sensor
°C
Hour
COOL FAN
Temperature/Timer settings
Temperature indicator Timer indicator
POWER/MODE BUTTON
POWER / MODE
Operating mode indicator
3-2-1 Cooling operation mode
The compressor is turned on and off according to the ambient temperature and set temperature.
1.Compressor on and off control
•Compressor on and off control according to the ambient temperature.
*The compressor is turned off when "ambient temperature = set temperature -1˚C"
*The compressor is turned on when "ambient temperature = set temperature +1˚C"
2.Default value after power reset set temperature = 18˚C
FAN SPEED = HIGH
3. Set temperature indicating (setting) range : 1˚C interval from 18˚C to 30˚C.
3-2-2 Fan operation mode
1.If "Fan operation mode" signal is received from remocon.
the compressor is immediately turned off and only fan motor is operated at set blowing speed.
it changes such as "HIGH LOW HIGH"( if Fan speed is selected).
2.The initial FAN speed is set to "HIGH".
3.The set temperature can not be indicated and set.
3-2 |