Samsung AW09A0KE User Manual

ENGLISH
Window-type Room Air Conditioner
(Cool)
Acondicionador de aire doméstico sistema de tipo ventana
(Refrigeración)
Climatiseur de type Fenêtre (Refroidissement)
O ar Condicionado de Window-Type (Refrigeração)
Condizionatore d’aria per ambienti da finestra (Raffreddamento)
DB98-04664A(4)
ESPAÑOL
FRANÇAIS
PORTUGUÊS
ITALIANO
OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION MANUAL DE INSTRUÇÕES ISTRUZIONI PER L’USO
AW07F0(1)(3)NAA/AB/BA/CA/DA/EA AW08F0(1)(3)NAA AW09F0(1)(3)NAA/BA/CA/DA/EA AW10F0(1)(3)DAA/BA/CA AW12F0(1)(3)DAA/BA/CA/DA/EA AW14F0(1)(3)MAA/AB/BA/CA/DA/EA AW18F0(1)(3)MBA/BB/BC/DA/EA/EB AW18F0(1)(3)MCA/CB/CC AWT18F0(1)(3)MBA/BB/DA/EA/EB AW22F0(1)(3)MBA/CA/DA/EA AW22F0(1)(3)MBB/CB/DB/EB AW24F0(1)(3)MBA/CA/CB/CC/CD/DA/EA AW24F0(1)(3)MBB/BC/BD/EB AWT24F0(1)(3)MBA/CA/DA/EA AWT24F0(1)(3)MBB/BC/EB/EC
AW07A(G)0(1)(3)NAA/AB/BA/CA/DA/EA AW08A(G)0(1)(3)NAA AW09A(G)0(1)(3)NAA/BA/CA/DA/EA AW10A(G)0(1)(3)DAA/BA/CA AW12A(G)0(1)(3)DAA/BA/CA/DA/EA AW14A(G)0(1)(3)MAA/AB/BA/CA/DA/EA AW18A(G)0(1)(3)MBA/BB/BC/DA/EA/EB AW18A(G)0(1)(3)MCA/CB/CC AWT18A(G)0(1)(3)MBA/BB/DA/EA/EB AW22A(G)0(1)(3)MBA/CA/DA/EA AW22A(G)0(1)(3)MBB/CB/DB/EB AW24A(G)0(1)(3)MBA/CA/CB/CC/CD/DA/EA AW24A(G)0(1)(3)MBB/BC/BD/EB AWT24A(G)0(1)(3)MBA/CA/DA/EA AWT24A(G)0(1)(3)MBB/BC/EB/EC
The following safety precautions must be taken when installing and using your air conditioner.
Safety Precautions
1 The air conditioner must be plugged into its own specific power source, which must be
installed in compliance with national wiring, earthing and safety regulations.
Depending on national regulations and your specific installation, you may need to install:
A circuit breaker
For further information on electrical requirements, contact a professional electrician.
This device must be installed according to the national electrical rules.
2 Make sure that the unit is correctly ventilated at all times;
do NOT place clothing or other materials over it.
4 Do NOT insert anything between the air outlet blades, as the inner fan may be damaged
and you may be hurt. Keep children away from the unit.
5 ALWAYS ensure that the power cable is in good condition.
Make sure that it is not walked on or damaged by items placed on or against it.
If the power cord is damaged in any way, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
6 Do NOT attempt to repair the unit yourself. If it is damaged in any way, contact:
An approved service center
The outlet at which the air conditioner was purchased
7 Do NOT place any obstacles in front of the unit.
3 NEVER spill liquid of any kind into the unit.
Should this happen, unplug the unit and contact your installation specialist.
The manufacturer do not take the responsibility of the accident happened because the air conditioner is not fixed firmly or installed securely, during installing or using the product. In case you have difficulty in installation, you must ask for an installation specialist help. The accident will be hap­pened in case of installing improperly.
CCCCAAAAUUUUTTTTIIIIOOOONN
NN
8
The appliance is not intended for use by young children or infirm person without supervision; young children should be supervised to ensure that they do not play with the appliance.
E-2
Contents
PREPARING YOUR AIR CONDITIONER
Safety Precautions ......................................................................................... 2
Air Conditioning Unit - Main Parts and Control Panel .................................... 4
OPERATING
YOUR AIR C
ONDITIONER
Cooling Your Room ........................................................................................ 5
Airing Your Room ........................................................................................... 6
Switching the Air Conditioner Off .................................................................... 6
Adjusting the Air Flow Direction Horizontally .................................................. 7
Adjusting the Air Flow Direction Vertically ...................................................... 7
Selecting Energy Saving Mode (Only ✴✴✴✴F3/A3/G3✴✴✴ models) .......... 8
RECOMMENDATIONS FOR USE
Operating Recommendation ........................................................................... 8
Temperature and Humidity Ranges ................................................................ 8
Cleaning Your Air Conditioner ........................................................................ 9
Solving Common Problems ............................................................................ 11
Technical Specifications ................................................................................. 12
INSTALLATION ....................................................................................................... 13
E-3
ENGLISH
CCCCAAAAUUUUTTTTIIIIOOOONN
NN
The maximum permissible system impedance at the power junction box is 0.24 ohms. Usually, the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A.
AW18✴✴
" The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions. This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker." Before connecting this equipment to the power supply system, please report to your supply authority and obtain the consent. Do not connect other electric appliances to the same supply lines.
The illustrations in the step-by-step procedures use four different symbols:
PRESS PUSH IMPORTANT NOTE
Air Conditioning Unit - Main Parts and Control Panel
Air filter
(The air filter is
located in inside.)
Air inlet (Inside)
Air outlet
Temperature control dial
Operating mode
selection dial
Temperature control dial
Operating mode selection dial
Temperature control dial
Air flow blade swing switch
Operating mode
selection dial
Energy Saver switch
Air flow blade swing
switch
Outer air flow blades (up/down orientation)
Air inlet (Outside)
Ventilation lever
Inner air flow blades (right/left orientation)
The design and shape are subject to
change according to the model.
E-4
✴✴✴✴F0/A0/G0✴✴✴
✴✴✴✴F1/A1/G1✴✴✴
✴✴✴✴F3/A3/G3✴✴✴
The type of the power plug may differ according to the type of local power supply.
The power plug may be not supplied
depending on the model.
Power plug
Power cable
Power cable connection should be committed to an installation engineer.
Blue Brown
Y ellow/Green
Main Power
Earth
Cooling Your Room
To cool your room with a... Set the operating mode
selection dial to...
High fan speed HI COOL Between HIGH and LOW MED COOL Low fan speed LOW COOL
Select the operating mode and fan speed.
You can change modes at any time.
You must select the Cool mode if you wish to lower the temperature in your room. You can also set the fan speed.
1
2
To control the direction of the air flow, refer to page 7.
3
To adjust the temperature, turn the temperature control dial to the desired position.
Possible temperatures: Between 18°C and 29°C inclusive.
Result: The air conditioner starts up in Cool mode.
The fan starts up at the speed selected.
Result:
The air conditioner starts cooling if the room temperature is
higher than the selected temperature.
27˚C ~ 23˚C
23˚C
~ 18˚C
29˚C
~ 27˚C
E-5