SAMSUNG AW07A0SE_CAF.41915.1.15 Service Manual

ROOM AIR CONDITIONER

AW07A0SE/AW07A1SE

AW09A0SE/AW09A1SE

SERVICE Manual

AIR CONDITIONER

CONTENTS

 

1.

Precautions

 

2.

Product Specifications

 

3.

Operating Instructions and

 

 

Installation

 

4.

Disassembly and Reassembly

 

5.

Troubleshooting

 

OFF

 

 

LOW

 

FANHI

COOL

 

 

 

 

HI

 

 

COOL

 

 

OPERATION

 

 

THERMOSTAT

 

6.Exploded Views and Parts List

7.Block Diagram

8.Wiring Diagram

ELECTRONICS

©Samsung Electronics Co., Ltd. MAR. 1999. Printed in Korea.

Code No. DB81-00066A(1)

SAMSUNG AW07A0SE_CAF.41915.1.15 Service Manual

1. Precautions

1.Warning: Prior to repair, disconnect the power cord from the circuit breaker.

2.Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.)

3.Use the proper tools: Use the proper tools and test equipment, and know how to use equipment may cause problems laterintermittent contact, for example.

4.Power Cord: Prior to repair, check the power cord and replace it if necessary.

5.Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.

6.After completing repairs and reassembly, check the insulation resistance, Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megohms.

7.Make sure that the grounds are adequate.

8.Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.

9.Keep children away from the unit while it is being repaired.

10.Be sure to clean the unit and its surrounding area.

Fig. 1-1 Avoid Dangerous Contact

Fig. 1-2 No Tapping and No Extension Cords

Fig. 1-3 No Kids Nearby!

Fig. 1-4 Clean the Unit

Samsung Electronics

1-1

2. Product Specifications

2-1 Table

Item

Unit of Measure

AW07A0SE

 

AW07A1SE

 

AW09A0SE

 

AW09A1SE

Remarks

 

 

 

 

 

 

 

 

 

 

Type

-

 

 

Window

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions:

mm (inch)

 

 

520 X 345 X 485 (20.5 X 13.6 X 19.1)

 

 

(Width X Height X Depth)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Size

mm (inch)

 

 

571 X 449 X 546 (22.5 X 17.7 X 21.5)

 

 

(Width X Height X Depth)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

Volt

 

220 - 240

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

-

 

 

Single

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Hz

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Current

A

 

3.5

 

4.5

 

 

 

 

 

 

 

 

 

 

 

 

Power Consumption

W

 

750

 

1,000

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Type

FREON

 

 

R-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Charge

g

 

410

 

420

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Capacity

KW

 

2.05

 

2.60

 

 

 

 

 

 

 

 

 

 

 

 

EER

KW/Wh

 

2.05

 

2.6

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight

kg

 

28

 

29

 

 

 

 

 

 

 

 

 

 

 

 

Condenser

Row

 

 

2 x15

 

 

 

 

 

 

 

 

 

 

 

 

 

Condenser Fan

Type

 

 

Propeller Fan

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator

Row

 

 

2 x14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Fan

Type

 

 

Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

W

 

 

IC - 9630SWJ5B

 

 

 

 

 

 

 

 

 

 

Compressor(Rotary)

Model

44A070JW1E1

 

44B092JW1E5

 

Overload Protect

-

MST24AMN - 12008

 

KRA1256 - 12007

 

Compressor Capacitor

 

25/370

 

 

20/370

 

 

 

µF/ VAC

 

Dual Type

 

Dual Type

 

 

 

 

 

Fan Motor Capacitor

 

2.5/370

 

 

3/370

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed Control

-

 

 

Fan speed switch(High & Low)

 

 

Themo Control

-

 

 

Thermostat

 

 

Air Swing

-

-

 

M2LJ49ZR42

 

-

 

M2LJ49ZR42

 

 

 

(5/6 RPM)

 

 

(5/6 RPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Samsung Electronics

2-1

2-2 Dimensions

2-2-1 Main Unit

Unit : mm

485

Front view

Side view

345

345

 

OFF

LOW

LOW

FAN

COOL

FANHI

COOLHI

OPERATION THERMOSTAT

520

2-2

Samsung Electronics

3. Installation and Operating Instructions

3-1 Installation

3-1-1 Selecting Area for Installation

1.Make sure that you install the unit in an area providing good ventilation. The air conditioner must not be blocked by any obstacles affecting the airflow near the air inlet and the air outlet.

2.Make sure that you install the unit in an area that allows good air handling. The installation area must be able to endure vibration from the unit.

3.Make sure that you install the unit away from heat or vapor.

4.Make sure that you install the unit in an area which is cool and has adequate space.

5.Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances (at least 1 meter clearance).

6.Make sure that you install the unit in an area which provides easy drainage for condensed water.

7.Make sure that you install the unit in area not exposed to the rain or direct sunlight.

(Install a separate sunblind if exposed to direct sunlight).

8.Make sure that you install the unit in an area allowing good air movement. Do not install it in a space that would cause noise amplification

of noise.

9.Fix the unit firmly if mounted in a high place.

Caution:

Do not use the air conditioner in the following environments : greasy areas (including areas near machines), or marine areas. Contact your local dealer for advice.

Samsung Electronics

3-1

Loading...
+ 13 hidden pages