5. Troubleshooting

5-1 Special Precautions

5-1-1 Check the voltage of the of power source.

The input voltage shall be 220 - 240V~ / 50Hz

The air conditioner may not operate properly if the voltage is out of this range.

5-1-2 Check weak and fragile parts. 5-1-3 Check the connection of terminals. 5-1-4 When a malfunction occurs:

No

Malfunction

Check point

 

Causes

 

 

 

 

 

 

Compressor does not run.

1. check the thermostat position.

1.

Setting temp is lower than room temp.

 

 

2. check the connection of the lead wire.

2.

Disconnection of the lead wire.

 

 

3. check the over load protector.

3.

O.L.P is faulty

 

 

4. check the compressor.

4.

Compressor is faulty

 

 

 

 

 

Motor does not run.

1. check the connection of the lead

1. disconnection of the lead wire

 

 

wire & switch.

2. switch is faulty.

 

 

2. check the motor

3. motor is faulty

 

 

 

 

 

 

Low cooling capacity

1. check the refrigerant leakage.

1.

Caused by the pipe crack

 

 

2. check the evaporator condition

2. shortage of refrigerant

 

 

( freezing, blocked with dusts, etc. )

3. clean the evaporator & air filter.

 

 

Difference of temp. exists between

 

 

 

 

the suction side and the discharge

 

 

 

 

side at least 12°C

 

 

 

 

Standard condition

 

 

 

 

Indoor : 27°C outdoor : 35°C

 

 

 

 

 

 

 

Noise

1. check vibration of the pipe

1. pipes are contact with the other parts.

 

 

2. check the propeller fan and blower

2. the hex. nut is loose

 

 

( not loose or broken ).

3. the parts are broken

 

 

3. check bearing noise of the motor

4. motor is faulty

 

 

4. check the compressor noise against

5. compressor is faulty

 

 

 

 

that of other compressors.

 

 

 

 

 