Samsung AW07A, AW07A0SE-CAF Operating Instructions

3. Installation and Operating Instructions

3-1 Installation

3-1-1 Selecting Area for Installation

1.Make sure that you install the unit in an area providing good ventilation. The air conditioner must not be blocked by any obstacles affecting the airflow near the air inlet and the air outlet.

2.Make sure that you install the unit in an area that allows good air handling. The installation area must be able to endure vibration from the unit.

3.Make sure that you install the unit away from heat or vapor.

4.Make sure that you install the unit in an area which is cool and has adequate space.

5.Make sure that you install the unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances (at least 1 meter clearance).

6.Make sure that you install the unit in an area which provides easy drainage for condensed water.

7.Make sure that you install the unit in area not exposed to the rain or direct sunlight.

(Install a separate sunblind if exposed to direct sunlight).

8.Make sure that you install the unit in an area allowing good air movement. Do not install it in a space that would cause noise amplification

of noise.

9.Fix the unit firmly if mounted in a high place.

Caution:

Do not use the air conditioner in the following environments : greasy areas (including areas near machines), or marine areas. Contact your local dealer for advice.

Samsung Electronics

3-1

Samsung AW07A, AW07A0SE-CAF Operating Instructions

3-2 Controls and Components

<AW07A0SE/AW09A0SE>

 

 

 

 

 

 

OFF

 

 

 

6

 

 

LOW

LOW

 

 

 

 

 

FAN

COOL

 

 

 

 

Operating mode

HI

HI

 

 

10

 

FAN

COOL

 

 

 

Temperature

 

 

 

 

 

selection dial

 

 

 

 

COOLEST

control dial

 

 

 

 

 

 

 

OPERATION

 

 

THERMOSTAT

 

<AW07A1SE/AW09A1SE>

 

 

 

 

 

 

OFF

 

 

 

6

 

 

LOW

LOW

 

4

8

 

 

FAN

COOL

 

 

 

 

Operating mode

HI

HI

2

 

10

 

FAN

COOL

 

 

 

Temperature

 

 

 

 

 

selection dial

 

 

 

 

12

control dial

 

 

 

 

 

COOLEST

 

 

OPERATION

 

 

THERMOSTAT

 

Air flow blade swing switch

3-2-1 Thermostat

OFF :

When room temperature is lowered by the air conditioner, the gas within the thermostat will contract and cause a break in the electrical contact. The compressor will then stop.

After the compressor stops, the room temperature will rise.

ON :

As the room temperature increases to a selected level, the gas within the thermostat expands causing electrical contact, which provides the source of electric power to the compressor. The room temperature will fall and the cycle will repeat.

Control Operation :

By turning the control knob clockwise (toward higher numbers), the temperature will be cooler. By turning the control knob counterclockwise (toward lower numbers), the temperature will be warmer.

Level 1 : Cool air will be supplied above 30~35°C Cool air will cease below 28~32.5°C

Level 12 : Cool air will be supplied above 17.4~20.4°C Cool air will cease below 14.4~17.4°C