Contents |
|
SafetyPrecautions ......................................................................................... |
3 |
|
Accessories ........................................................................................................ |
5 |
|
SelectingtheInstallationLocation ........................................................ |
6 |
|
IndoorUnitInstallation ............................................................................... |
8 |
|
|
PurgingtheUnit ............................................................................................. |
10 |
|
ConnectingtheRefrigerantPipe ............................................................ |
11 |
|
Cutting/FlaringthePipes ........................................................................... |
12 |
|
PerformingLeakTest&Insulation ......................................................... |
13 |
|
DrainpipeandDrainHoseInstallation ................................................ |
15 |
|
WiringWork ...................................................................................................... |
18 |
|
IndoorUnitSetting ....................................................................................... |
21 |
|
AdditionalFunctions .................................................................................... |
22 |
|
FinalChecksandUserTips ........................................................................ |
23 |
|
Troubleshooting ............................................................................................. |
24 |
E-2
AVXC4@@_IM_E_31758_1.13.10.indd 2 |
|
|
2010-1-13 16:59:38 |
|
|
||
|
|
|
|
Safety Precautions
(Carefullyfollowtheprecautionslistedbelowbecausetheyareessentialtoguaranteethesafetyoftheequipment.)
WARNING |
• Alwaysdisconnecttheairconditionerfromthepowersupplybeforeservicingitor |
|
accessingitsinternalcomponents. |
|
• Verifythatinstallationandtestingoperationsareperformedbyqualifiedpersonnel. |
|
• Verifythattheairconditionerisnotinstalledinaneasilyaccessiblearea. |
GENERAL INFORMATION |
|
|
|
Carefullyreadthecontentofthismanualbeforeinstallingtheairconditionerandstorethemanualinasafeplaceinordertobe abletouseitasreferenceafterinstallation.
Formaximumsafety,installersshouldalwayscarefullyreadthefollowingwarnings.
Storetheoperationandinstallationmanualinasafelocationandremembertohanditovertothenewownerifthe airconditionerissoldortransferred.
ThismanualexplainshowtoinstallanindoorunitwithasplitsystemwithtwoSAMSUNGunits.Theuseofothertypesofunits withdifferentcontrolsystemsmaydamagetheunitsandinvalidatethewarranty.Themanufacturershallnotberesponsiblefor damagesarisingfromtheuseofnoncompliantunits.
Themanufacturershallnotberesponsiblefordamageoriginatingfromunauthorizedchangesortheimproperconnectionofelectric andhydrauliclines.Failuretocomplywiththeseinstructionsortocomplywiththerequirementssetforthinthe“Operatinglimits” table,includedinthemanual,shallimmediatelyinvalidatethewarranty.
Theairconditionershouldbeusedonlyfortheapplicationsforwhichithasbeendesigned:theindoorunitisnotsuitabletobe installedinareasusedforlaundry.
Donotusetheunitsifdamaged.Ifproblemsoccur,switchtheunitoffanddisconnectitfromthepowersupply.
Inordertopreventelectricshocks,firesorinjuries,alwaysstoptheunit,disabletheprotectionswitchandcontactSAMSUNG’s technicalsupportiftheunitproducessmoke,ifthepowercableishotordamagedoriftheunitisverynoisy.
Alwaysremembertoinspecttheunit,electricconnections,refrigeranttubesandprotectionsregularly.Theseoperationsshouldbe performedbyqualifiedpersonnelonly.
Theunitcontainsmovingparts,whichshouldalwaysbekeptoutofthereachofchildren.
Donotattempttorepair,move,alterorreinstalltheunit.Ifperformedbyunauthorizedpersonnel,theseoperationsmaycause electricshocksorfires.
Donotplacecontainerswithliquidsorotherobjectsontheunit.
Allthematerialsusedforthemanufactureandpackagingoftheairconditionerarerecyclable.
Thepackingmaterialandexhaustbatteriesoftheremotecontrol(optional)mustbedisposedofinaccordancewithcurrentlaws.
Theairconditionercontainsarefrigerantthathastobedisposedofasspecialwaste.Attheendofitslifecycle,theairconditioner mustbedisposedofinauthorizedcentersorreturnedtotheretailersothatitcanbedisposedofcorrectlyandsafely.
INSTALLING THE UNIT
IMPORTANT: Wheninstallingtheunit,alwaysremembertoconnectfirsttherefrigeranttubes,thentheelectricallines.
Alwaysdisassembletheelectriclinesbeforetherefrigeranttubes.
Uponreceipt,inspecttheproducttoverifythatithasnotbeendamagedduringtransport.Iftheproductappearsdamaged, DONOTINSTALLitandimmediatelyreportthedamagetothecarrierorretailer(iftheinstallerortheauthorizedtechnicianhas collectedthematerialfromtheretailer.)
Aftercompletingtheinstallation,alwayscarryoutafunctionaltestandprovidetheinstructionsonhowtooperate theairconditionertotheuser.
Donotusetheairconditionerinenvironmentswithhazardoussubstancesorclosetoequipmentthatreleasefreeflamestoavoid theoccurrenceoffires,explosionsorinjuries.
The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installedinareasusedforlaundry.
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from bothsidesorabilitytoperformroutinemaintenanceandrepairs.Theunits’componentsmustbeaccessibleandthatcanbe disassembledinconditionsofcompletesafetyeitherforpeopleorthings.
Forthisreason,whereitisnotobservedasindicatedintotheInstallationManual,thecostnecessarytoreachandrepairtheunit(in safety,asrequiredbycurrentregulationsinforce)withslings,trucks,scaffoldingoranyothermeansofelevationwon’tbe consideredin-warrantyandchargedtoenduser.
POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER
Alwaysmakesurethatthepowersupplyiscompliantwithcurrentsafetystandards.Alwaysinstalltheairconditionerincompliance withcurrentlocalsafetystandards.
Alwaysverifythatasuitablegroundingconnectionisavailable.
Verifythatthevoltageandfrequencyofthepowersupplycomplywiththespecificationsandthattheinstalledpowerissufficient toensuretheoperationofanyotherdomesticapplianceconnectedtothesameelectriclines.
Alwaysverifythatthecut-offandprotectionswitchesaresuitablydimensioned.
Verifythattheairconditionerisconnectedtothepowersupplyinaccordancewiththeinstructionsprovidedinthewiring diagramincludedinthemanual.
Alwaysverifythatelectricconnections(cableentry,sectionofleads,protections…)arecompliantwiththeelectricspecifications andwiththeinstructionsprovidedinthewiringscheme.Alwaysverifythatallconnectionscomplywiththestandardsapplicable
totheinstallationofairconditioners. |
E-3 |
ENGLISH
AVXC4@@_IM_E_31758_1.13.10.indd 3 |
|
|
2010-1-13 16:59:38 |
|
|
||
|
|
|
|
Safety Precautions (Continued)
Makesurethatyouearththecables.
-Donotconnecttheearthwiretothegaspipe,waterpipe,lighting rodortelephonewire.Ifearthingisnotcomplete,electricshockor firemayoccur.
Installthecircuitbreaker.
-Ifthecircuitbreakerisnotinstalled,electricshockorfiremayoccur.
Makesurethatthecondensedwaterdrippingfromthedrainhose runsoutproperlyandsafely.
Installthepowercableandcommunicationcableoftheindoorand outdoorunitatleast3.3ft(1m)awayfromtheelectricappliance.
Installtheindoorunitawayfromlightingapparatususingtheballast. -Ifyouusethewirelessremotecontrol,receptionerrormayoccur duetotheballastofthelightingapparatus.
Donotinstalltheairconditionerinfollowingplaces. -Placewherethereismineraloilorarsenicacid.
Resinpartsflameandtheaccessoriesmaydroporwatermayleak. Thecapacityoftheheatexchangermayreduceortheairconditioner maybeoutoforder.
-Theplacewherecorrosivegassuchassulfurousacidgasgenerates fromtheventpipeorairoutlet.
Thecopperpipeorconnectionpipemaycorrodeandrefrigerant mayleak.
-Theplacewherethereisamachinethatgenerateselectromagnetic waves.
Theairconditionermaynotoperatenormallyduetocontrolsystem.
-Theplacewherethereisadangerofexistingcombustiblegas, carbonfiberorflammabledust.
Theplacewherethinnerorgasolineishandled. Gasmayleakanditmaycausefire.
E-4
AVXC4@@_IM_E_31758_1.13.10.indd 4 |
|
|
2010-1-13 16:59:39 |
|
|
||
|
|
|
|
Accessories
The following accessories are supplied with the indoor unit.
The type and quantity may differ depending on the specifications.
AVXC4/ND4H |
|
|
|
|
Patternsheet |
Insulationcoverband |
Insulationdrainhose |
Insulationpipe |
Cable-tie |
Flexiblehose |
M4x12tappedScrew |
Insulationdrainsub |
Padstopper |
Installationmanual |
Safetynet |
M4x12tappedScrew |
|
|
|
ENGLISH
E-5
AVXC4@@_IM_E_31758_1.13.10.indd 5 |
|
|
2010-1-13 16:59:40 |
|
|
||
|
|
|
|
Selecting the Installation Location
Indoor Unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.
Maintain sufficient clearance around the indoor unit.
Make sure that the water dripping from the drain hose runs away correctly and safely.
The indoor unit must be installed in this way, that they are out of public access. (Not touchable by the users)
Rigid wall without vibration.
Where it is not exposed to direct sunshine.
Where the air filter can be removed and cleaned easily.
Asarule,theunitcannotbeinstalledataheightoflessthan8.3ft(2.5m).
Itispossibletoinstalltheunitataheightofbetween7.3~8.3ft(2.2~2.5m) fromtheground,iftheunithasaductwithawelldefinedlength (11.81inch(300mm)ormore)toavoidfanmotorblowercontact.
Space Requirements for Indoor Unit
AVXC4/ND4H
59inch(1500mm)
ormore
59inch(1500mm) |
59inch(1500mm) |
or |
|
more |
|
|
or |
|
more |
|
ormore |
|
59inch(1500mm) |
E-6
AVXC4@@_IM_E_31758_1.13.10.indd 6 |
|
|
2010-1-13 16:59:41 |
|
|
||
|
|
|
|
Dimension of the indoor unit
AVXC4/ND4H
Unit:inch(mm)
|
37.40’’(950) |
33.86’’~35.04’’(860~890) |
Ceiling opening |
|
|
27.52’’(699)Suspension position |
|
||
|
|
|
||
|
|
|
position |
opening |
37.40”(950) |
|
5 |
30.16’’(766)Suspension |
33.86’’~35.04’’(860~890)Ceiling |
|
6 |
|||
|
|
|
|
AVXC4052/072 |
|
|
|
|
|
||||||
ND052/0724H |
|
|
|
|
|
||||||
|
28.19’’(716) |
|
8.58’’(218) |
6.54’’(166) |
21.65’’ (550) Adjustable |
|
|
|
|
|
|
|
|
1.61’’ |
(41) |
|
|
9.53’’(242) |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12.67’’(322) |
9.69’’(246) |
|
|
|
|
|
|
|
|
|
|
12.01’’(305) |
|
|
|||
AVXC4100/110/145 |
|
|
|
||||||||
ND100/110/1454H |
|
|
|
|
|||||||
29.49’’(749) |
11.73’’(298) |
|
|
|
21.65’’(550) Adjustable |
3 |
|
|
|
|
6.30’’(160) |
2.24’’ |
33.07’’(840) |
|
|
2.24’’ |
|||||||
|
|
|
|
|
|
||||||
|
|
(57) |
|
|
|
|
|
(57) |
|
||
1.61’’ |
(41) |
7.87’’(200) |
|
|
|
9.53’’(242) |
|
2.52’’(64) |
7.48’’(190) |
||
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
12.67’’(322) |
12.01’’(305)9.69’’(246) |
4 |
1 |
2 |
|
2.24’’ |
|
33.07’’(840) |
|
|
(57) |
0.98’’ |
10.24’’(260) |
0.98’’ |
|
|
|||
|
|
(25) |
11.42’’(290) |
(25) |
9.06’’(230) |
3.94’’(100) |
3.15’’(80) |
|
|
2.24’’ |
|
|
(57) |
|
|
|
8.19’’(208) |
(2500) |
Branch duct |
98.43’’ |
connection
2.24’’ |
|
|
33.07’’(840) |
2.24’’ |
|
(57) |
|
0.98’’ |
10.24’’(260) |
0.98’’ |
(57) |
12.20’’(310) |
6.22’’(158) |
(25) |
11.42’’(290) |
(25) |
8.19’’(208) |
2.68’’(68) |
|
|
|||
|
5.43’’(138) |
|
|
|
98.43’’(2500) moreor requiredspace |
|
|
|
Branch duct |
connection
No. |
Name |
Description |
|
|
|
|
|
|
Liquid pipe connection |
052: ø1/4”(6.35) |
|
072/100/110/145: ø3/8”(9.52) |
|||
|
|
||
|
Gas pipe connection |
052: ø1/2”(12.70) |
|
072/100/110/145: ø5/8”(15.88) |
|||
|
|
||
|
Drain pipe connection |
VP25(ODø11/4”(32),IDø1”(25)) |
|
|
Power supply connection |
- |
|
|
Air discharge grille |
- |
|
|
Air suction grille |
- |
E-7
ENGLISH
AVXC4@@_IM_E_31758_1.13.10.indd 7 |
|
|
2010-1-14 14:05:42 |
|
|
||
|
|
|
|
Indoor Unit Installation
Concrete |
Insert |
Holeinanchor |
Holeinplug |
Suspensionbolt(3/8"orM10) |
Ceilingsupport |
ItisrecommendedtoinstalltheY-jointbeforeinstallingtheindoorunit.
1Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit.
Note Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity. For this reason, before drilling the holes maintain the correct dimensions between the markings.
2Insert bolt anchors, use existing ceiling supports or construct a suitable support as shown in figure.
3Install the suspension bolts depending on the ceiling type.
Ensure that the ceiling is strong enough to support the weight of the indoor unit. Before hanging the unit, test the strength of each attached suspension bolt.
If the length of suspension bolt is more than 4.94ft(1.5m), it is required to prevent vibration.
If this is not possible, create an opening on the false ceiling in order to be able to use it to perform the required operations on the indoor unit.
E-8
AVXC4@@_IM_E_31758_1.13.10.indd 8 |
|
|
2010-1-13 17:00:04 |
|
|
||
|
|
|
|
4Screw eight nuts to the suspension bolts making space for hanging the indoor unit.
You must install the suspension bolts more than four when installing
the indoor unit.
5Check the level of the indoor unit by using a leveler.
Atiltoftheindoorunitmaycausemalfunctionofabuilt-infloatswitch andwaterleaks.
6Adjust the height of the indoor unit by using the gauge of dimensions.
Youshouldadjustthegaugeofdimensionsandthepatternsheettofit thecuttingdimensionsofceiling.
Makesurethattheindoorunitisinstalledataleveliftheindoorunit slantstoomuch,therecanbewaterleaks.
AVXC4/ND4H
IndoorUnit |
0.79inch(20mm) |
|
Ceiling 1.38inch(35mm)
Gaugeof
Dimensions
7Tighten the upper part nuts.
8Remove the gauge of dimensions after installing the indoor unit.
ENGLISH
Nut
Washer
Rubber
Fastenthenut
Level
E-9