FUNCTION OF KEY
Use this button to start and stop air conditioner.
Each time you press this button,
MODE is changed in the following order.
"AUTO""COOL" "DRY" "FAN"
Use this button to provide heavy duty cooling
for 30 minutes.
Use this button to provide pleasant cooling
for 3 hours.
Set up the reserve or cancel the timer on and timer off quickly.
Each time you press this button,
FAN SPEED is changed in the following order.
"AUTO" " (L)" " (ME)" " (HI)" NATURAL
Adjusts air flow vertically.
Each time you press this button,
BLADE-H rotates by 8° (Changable range 50°).
Each time you press this button,
BLADE-H rotates within 35° and stop.
ONE SHOT KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
ONE SHOT KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
10
11
12
13
8
9
TIME
TIMER/CANCEL
TIMER
TIME
TEMP
SLEEP
ON
OFF
(UP)
(DOWN)
(UP)
(DOWN)
Without regard to ON/OFF condition in remote controller,
use this button to set current time.
Adjust the current time using TIME button.
(Data can be transmitted after setting up the time)
Use this button to reserve or cancel the timer on and timer off.
Set up the time that operation start.
Set up the time that operation stop.
If the TIME button is pressed once, the time increase by one
minute during the time set mode, and ten minutes during the
timer set mode.
If the TIME button is pressed once, the time decrease by one
minute during the time set mode, and ten minutes during the
timer set mode.
If the button is pressed once,
the setting temperature is increased by 1°C.
If the button is pressed once,
the setting temperature is decreased by 1°C.
Use this button for sleep operation.
(The SLEEP mode can be selected at COOL mode.
ONE SHOT KEY
ONE SHOT KEY
ONE SHOT KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
OR
CONTINUOUS KEY
ONE SHOT KEY
Samsung Electronics
3-1
Operating Instructions and Installation
3-1-2 Main controller function.
1. A U TO MODE: In this mode, operation
mode (COOL) is selected automatically by
the room temperature of initial operation.
Operation Type
Cool Operation (Set Temp:24°C + ∆T)
∆T= -1°, -2°C, 0°C, +1°C, +2°C
∆T is controlled by setting temperature
up/down key of remote contro l l e r
2. C O O L MODE: The unit operates accord i n g
to the diff e rence between the setting and
room temperature .
The setting temperature range is
1 8 ° C t h rough 30°C.
3. D RY MODE: The unit is operated at comp ressor on state re g a rdless of room tempera t u re for an initial 30 minutes of dehumidification operation, and the indoor fan motor
is automatically operated due to the tempera t u re diff e rence between the room temperat u re and set temperature .
The compressor is automatically contro l l e d
due to the temperature diff e rence between
room temperature and set temperature after
operation of 30 minutes.
* Set temperature: 18°C~30°C
* Protective function: Low temperature
release. (Prevention against fre e z e )
4. TURBO MODE: This mode is available only
in A U TO, COOL m o d e .
When this button is pressed at first, the air
conditioner is operated “powerful” state for
30 minutes re g a rdless of the set temperat u re, room temperature .
When this button is pressed again, or when
the operating time is 30 minutes, turbo
operation mode is canceled and returned to
the previous mode.
5 . MILD MODE: This mode is available only
in A U TO, COOL m o d e .
When this button is pressed at first, the air
conditioner is operated in its current state
for 3 hours.
The setting temperature is automatically
raised by 3°C.
When this button is pressed again or when
the operating time is 3 hours, mild operation mode is canceled and returned to the
p revious mode.
6 . S L E E P MODE: Sleep mode is available only
in COOL m o d e .
The operation will stop after 6 hours.
* In COOL mode : The setting temperature
is automatically raised by 1°C each 1hour
When the temperature has been raised by
total of 2°C, that temperature is maint a i n e d .
7. FAN SPEED: Manual (3 step), Auto (4 step),
N a t u r a l
Fan speed automatically varies depending
on both the diff e rence between setting and
the room temperature .
8 . C O M P U L S O RY O P E R ATION:
For operating the air conditioner without
the remote contro l l e r.
The operating is the same function that
A U TO MODE in the remote contro l l e r.
* Set temperature: 22°C
3-2
Samsung Electronics
Operating Instructions and Installation
9 . SWING: BLADE-H is rotated vertically by
the stepping motor.
* Memory louve: When ON/OFF button is
p ressed at stop state, the BLADE-H re t u r n s
to its original location which is operating
state before stop.
* Swing auto: The BLADE-H can ro t a t e
within about 35° in the original position set
by the SWING SET button.
* Swing set: Press the SWING SET button,
then the blade rotates vertically by 8°
The BLADE-H location is dispalyed on
REMOTE CONTROL. (total 7 steps)
1 0 . Q.TIMER: Q. timer (quick timer) allows
reservation or cancel the timer on and timer
o ff quickly.
When Q.timer button is pressed at operating state, LCD displays the polling state
s e q u e n t i a l l y.
The LCD also displays the time re m a i n i n g .
1 2 . SELF TEST
* Interruption of electric power and Power
o n .
* Abnormal condition of the room sensor.
* Indoor unit fan motor lock.
* Abnormal condition of the indoor unit's
heat exchanger sensor.
1 3 . TIME SHORTENING: If the "Time short"
connector pin is shorted on the main P. C. B,
the compressor's three minutes delay function is cancelled, and each operation time is
shortened to one fiftieth of its original time.
1 4 . BUZZER SOUND: Whenever the ON/OFF
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep".
11 . TIMER: The air conditioner is turned
ON/OFF at a specified time using TIMER
O N / O F F.
* Timer LED lights on.
Samsung Electronics
3-3
3-2 Installation
3-2-1 Selecting Area for Installation
Select an area for installation that is suitable
to the customer's needs.
3-2-1(a) Indoor Unit
1 . Make sure that you install the indoor unit in
an area providing good ventilation. It must
not be blocked by an obstacle affecting the
airflow near the air inlet and the air outlet.
2 . Make sure that you install the indoor unit in
an area allowing good air handling and
endurance of vibration of the indoor unit.
3. Make sure that you install the indoor unit in
an area where there is no source of heat or
vapor nearby.
4 . Make sure that you install the indoor unit in
an area from which hot or cool air is spre a d
evenly in a ro o m .
5 . Make sure that you install the indoor unit in
an area away from TVs, audio units, cordless phones, fluorescent lighting fixture s
and other electrical appliances (at least 1
m e t e r ) .
6 . Make sure that you install the indoor unit in
an area which provides easy pipe connection with the outdoor unit, and easy
drainage for condensed water.
7. Make sure that you install the indoor unit in
an area which is large enough to accomodate the measurements shown in figure on
the next page.
3-2-1(b) Outdoor Unit
1 . Make sure that you install the outdoor unit
in area not exposed to the rain or direct sun
l i g h t .
(Install a separate sunblind if exposed to
d i rect sun light.)
2 . Make sure that you install the outdoor unit
in area allowing good air moment, not
amplifying noise or vibration, especially to
avoid disturbing neighbours.
(Fix the unit firmly if it is mounted in a
high place.)
3 . Make sure that you install the outdoor unit
in area providing good ventilation and
which is not dusty. It must not be blocked
by any obstacle affecting the airflow near
the air inlet and the air outlet.
4 . Make sure that you install the outdoor unit
in area free from animals or plants.
5 . Make sure that you install the outdoor unit
in area not blocking the traff i c .
6. Make sure that you install the outdoor unit
in area easy to drain condensed water fro m
the indoor unit.
7. Make sure that you install the outdoor unit
in area which provides easy connection
within the maximum allowable length of a
coolant pipe (15 meters).
Note
1. Add 10 grams of refrigerant (R-22) for
every 1 meter if the pipe length exceeds
the standard pipe length of 5 meters.
2. Maintain a height between the indoor and
outdoor units of less than 3 meters.
8 . Make sure that you install the outdoor unit
in an area which is large enough to accommodate the measurements
shown in figure on the next page.
3-2-1(c) Remote Control Unit
1 .Make sure that you install the remote con-
t rol unit in an area free from obstacles such
as curtains etc, which may block signals
f rom the remote control unit.
2. Make sure that you install the remote cont rol unit in an area not exposed to
d i rect sunlight, and where there is no sourc e
of heat.
3. Make sure that you install the remote cont rol unit in an area away from TVs, audio
units, cordless phones, fluorescent lighting
f i x t u res and other electrical appliances (at
least 1 meter).
Caution :
It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas near machines),
salty areas such as coast areas, areas where sulfuric gas is present such as hot spring areas. Contact your dealer for advice.
3-4
Samsung Electronics
Operating Instructions and Installation
3-2-2 Installation diagram of indoor unit and outdoor unit
GAS LEAK TESTSlope of drain hose* Piping may be laid to the rear, left, right or down.
Avoid up
Indoor unit check
points
slopes
Right
Left
Outdoor unit
check points
* Check for gas leak from the flare nut
connections with leak detector.
5 6
250mm
m i n i m u m
4
Rear
Down
Insulation of pipe connection area
* Perform gas leakage test first, and insulate the pipe
connection area.
Use an insulation tube for insulation as shown in figure.
The insulation
tube shall be
properly finished
not to allow
any gap.
Left rear
350mm or more
Vinyl tape
(purchase locally)
Remote control
Remote control holder
Hole dimension of bolts for the outdoor unit
Insulation
tube
Coolant adjustment pro c e d u re
C l a s s
C o n n e c t i o n
pipe lengh
At installationAt installation
A i r- p u rg e
m e t h o d
C o o l a n t
a d j u s t m e n t
u n n e c e s s a ry
5m max
Refer to the
detailed
a i r- p u rg e
p ro c e d u re .
Add 10g of
c o o l a n t
5 ~ 1 0 m
<R-22> for
e v e ry 1m.
(Refer to
the detailed
c o o l a n t
c h a rg e
p ro c e d u re . )
Samsung Electronics
Air purg e
m e t h o d
P u rge air
using
a vacuum
pump or an
a d d i t i o n a l
c o o l a n t
c y l i n d e r.
R e f r i g e r a n t
q u a n t i t y
See table
r i g h t .
Add 10g of
c o o l a n t
<R-22> for
e v e ry 1m.
(Refer to
the detailed
c o o l a n t
c h a rg e
p ro c e d u re . )
10
Fix firmly if installed in an area affected by typhoons.
582
Coolant adjustment pro c e d u rekg .cm
Outer diameterFixing torqueFinal torque
ø6.35mm160200
ø12.7mm500550
ø15.8mm700750
Tighten the flare nut by hand first, and tighten firmly with a spanner
C o o l a n t - q u a n t i t y
M o d e l
Coolant quantity
R e m a r k
A S 1 8 0 U E / A S 1 8 1 U E1 5 8 0 gSelf refrigerant is included with shipment.
A S 1 8 0 U D / A S 1 8 1 U D1 5 5 0 gSelf refrigerant is included with shipment.
A S - 2 4 0 8 B R1 6 5 0 gSelf refrigerant is included with shipment.
For more information refer to the Installation Manual.