9. Wiring Diagram
9-1 Indoor Unit
VA701 VARISTOR RY705 MOTOR IN(TURBO) DRIVE RELAY
RTH ROOM THERMISTOR SENSOR RY706
RY702 COMP. DRIVE RELAY RY708
RY703 4-WAY V/V DRIVE RELAY RY709
RY704 OUTDOOR FAN DRIVE RELAY RY710
ERROR MODE
"E0" GAS SENSOR ERROR "E5" EVAP. THERMISTOR ERROR
"E1" ROOM THERMISTOR ERROR "E6" COND. THERMISTOR ERROR
"E2" SHUTTER MOTOR ERROR "EA"
"E3" PERFECT CLEANER FAN MOTOR ERROR
MOTOR IN(HIGH) DRIVE RELAY
MOTOR IN(MED) DRIVE RELAY
MOTOR IN(LOW) DRIVE RELAY
SHUTTER MOTOR DRIVE RELAY(OPEN)
SHUTTER MOTOR DRIVE RELAY(CLOSE)
MAIN-PANEL PCB COMMUNICATION ERROR
This Document can not be used without Samsung's authorization.
Code No : DB98-15796A
Samsung Electronics54
9-2 Outdoor Unit
CM COMPRESSOR TP 1.2 TERMINAL PLATE
52C1 MAGNETIC CONTACTOR 20S SOLENOID COIL
CPC CAPACITOR FOR COMP SPK SPARK KILLER
FM FAN MOTOR 63H HIGH PRESSURE S/W
CPM CAPACITOR FOR MOTOR F1 FUSE(250V/2A)
Code No : DB98-03401A
This Document can not be used without Samsung's authorization.
55Samsung Electronics