Samsung AD24, AD18 Operating Instructions

3. Operating Instructions and Installation
3-1 Operating Instructions
3-1-1 Name & Function of Key in remote controller
NO
3
MODE
4 5
6
7
TURBO
OFF
(UP)
(DOWN)
On/Off Button. Use this button to start and stop air conditioner. Temp. up button.
If the button is pressed once, the setting temperature is increased by 1°C Temp. down button.
If the button is pressed once, the setting temperature is decreased by 1°C Each time you press this button,
MODE is changed in the following order.
Use this button to provide heavy duty cooling & Heating for 30 minutes.
Set up the reserve or cancel the timer off quickly
Use this button for sleep operation. (The SLEEP mode can be selected at COOL and HEAT mode.)
Adjusts air flow vertically, each time you press this button.
FUNCTION OF KEY
: Auto Mode : Cool Mode : Dry Mode
: Fan Only : Heat Mode
10 11 12 13
14
15
Each time you press this button,
8
C
9
O V E R
T
I
M
E R
ON TIMER OFF TIMER
SET CANCEL
(UP)
(DOWN)
TIME
FAN SPEED is changed in the following order.
Set up the time that operation start. Set up the time that operation stop.
Use this button to reserve the timer on and timer off. Use this button to cancel the timer on and timer off.
If the button is pressed once, the time increase by one minute during the time set mode, and ten minutes during the timer set mode.
If the button is pressed once, the time decrease by one minute during the time set mode, and ten minutes during the timer set mode.
Without regard to ON/OFF condition in remote controller, use this button to set current time. Adjust the current time using button. (Data can be transmitted after setting up the time)
Samsung Electronics
3-1
Operating Instructions and Installation
3-1-1(a) Heat Pump
1. A U TO MODE : In this mode, operation mode(COOL, HEAT, DRY) is selected auto­matically by the room temperature of initial o p e r a t i o n .
Room Temp Tr 21°C+T 21°C +T>Tr
T= -2°C, -1°C, 0°C, +1°C, +2°CT is controlled by setting temperature
up/down key of remote contro l l e r
2. C O O L MODE : The unit operates accord i n g to the diff e rence between the setting and room temperature. (18°C~30°C)
3. H E AT MODE : The unit operates accord i n g to the diff e rence between the setting and room temperature.(16°C~30°C) * P revention against cold wind : For about 3~5 minutes after initial operation, thermo c o n t rol or “de-ice”, the indoor fan will either not operate or operate very slow­ly(510 rpm), then switch to the selected fan speed. This period is to allow the indoor unit's heat-exchanger to prewarm before emitting warm air. *High temperature release function : The outdoor unit for and compressor ON/OFF c o n t rol for safety operation, when the over­heat is heat exchanger of indoor unit. *De-ice : Deicing operation is controlled by indoor unit's heat exchanger temperature and accumulating time of compre s s o r ' s o p e r a t i o n . De-ice end by sensing of the pro c e s s i n g time by de-ice condition.
Cool Operation (Set Temp:AUTO SETTING)
Heat Operation (Set Temp : 22°C+T)
Operation Type
4. D RY MODE : Has 3 states, each determined by room temperature . The unit operates in DRY m o d e . *Co m p ressor ON/OFF Time is contro l l e d compulsorily(can not set up the fan speed, always bre e z e ) . * P rotective function : Low temperature release. (Prevention against fre e z e )
5. TURBO MODE : This mode is available in A U TO, COOL, HEAT, DRY, FAN MODE. When this button is pressed at first, the air conditioner is operated “powerful” state for 30 minutes re g a rdless of the set tempera­t u re, room temperature . When this button is pressed again, or when the operating time is 30 minutes, turbo operation mode is canceled and returned to the previous mode. *But, if you press the TURBO button in DRY or FAN mode that is changed with A U TO mode automatically.
6 . S L E E P MODE : Sleep mode is available
only in COOL or HEAT mode. The operation will stop after 6 hours. *In COOL mode : The setting temperature is automatically raised by 1°C each 1hour When the temperature has been raised by total of 2°C, that temperature is main­t a i n e d . *In HEAT mode : The setting temperature is automatically droped by 1°C each 1hour. When the temperature has been droped by total of 2°C, that temperature is main­t a i n e d .
7. FAN SPEED : Manual (3 step), Auto (4 step) Fan speed automatically varies depending on both the diff e rence between setting and the room temperature .
3-2
Samsung Electronics
Operating Instructions and Installation
8 . C O M P U L S O RY O P E R ATION :
For operating the air conditioner without the remote contro l l e r. * A U TO : The operating is the same func­tion that A U TO MODE in the remote con­t ro l l e r.
9 . SWING : BLADE-H is rotated vertically by
the stepping motor. *Memory louver : When ON/OFF button is p ressed at stop state, the BLADE-H re t u r n s to its original location which is operating state before stop *Swing Set : Press the button under the remote control is displayed on LCD the , and the blades move up and down, about 43°. If the one more time press the button, bla­tles location is stop.
1 0 . Quick OFF TIMER: OFF timer (quick timer)
allows reservation or cancel the timer off quickly When OFF timer button is pressed at oper­ating state, LCD displays the polling state s e q u e n t i a l l y. The LCD also displays the time re m a i n i n g .
11 . 24-Hour ON/OFF Real Setting Ti m e r. : The
air conditioner is turned ON at a specified time using .
ON TIMER
OFF TIMER : The air Conditioner is turned OFF at a specified time using .
OFF TIMER
*ON TIMER : Only timer LED lights on. *OFF TIMER : Both timer and operation LED lights on. *3 minutes delay timer.
1 2 . SELF Diagnosis
LED DISPLAY
o p e r-
T I M E R
a t i o n
FA N
Tu r b o
Check Point
I n t e r ruption of electric power and Power on. Abnormal condition of the room sensor.
Abnormal condition of the indoor unit's heat exchanger sensor. Indoor unit fan motor lock.
: LED blinking
: LED off
1 3 . BUZZER SOUND : Whenever the ON/OFF
button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep"
Samsung Electronics
3-3
3-2 Installation
3-2-1 Selecting Area for Installation
Select an area for installation that is suitable to the customer's needs.
3-2-1(a) Indoor Unit
1 . Make sure that you install the indoor unit in
an area providing good ventilation. It must not be blocked by an obstacle affecting the airflow near the air inlet and the air outlet.
2 . Make sure that you install the indoor unit in
an area allowing good air handling and endurance of vibration of the indoor unit.
3. Make sure that you install the indoor unit in an area where there is no source of heat or vapor nearby.
4 . Make sure that you install the indoor unit in
an area from which hot or cool air is spre a d evenly in a ro o m .
5 . Make sure that you install the indoor unit in
an area away from TVs, audio units, cord­less phones, fluorescent lighting fixture s and other electrical appliances (at least 1 m e t e r ) .
6 . Make sure that you install the indoor unit in
an area which provides easy pipe connec­tion with the outdoor unit, and easy drainage for condensed water.
7. Make sure that you install the indoor unit in an area which is large enough to accomo­date the measurements shown in figure on the next page.
3-2-1(b) Outdoor Unit
1 . Make sure that you install the outdoor unit
in area not exposed to the rain or direct sun l i g h t .
(Install a separate sunblind if exposed to
d i rect sun light.)
2 . Make sure that you install the outdoor unit
in area allowing good air moment, not amplifying noise or vibration, especially to
avoid disturbing neighbours.
(Fix the unit firmly if it is mounted in a
high place.)
3 . Make sure that you install the outdoor unit
in area providing good ventilation and which is not dusty. It must not be blocked by any obstacle affecting the airflow near the air inlet and the air outlet.
4 . Make sure that you install the outdoor unit
in area free from animals or plants.
5 . Make sure that you install the outdoor unit
in area not blocking the traff i c .
6. Make sure that you install the outdoor unit in area easy to drain condensed water fro m the indoor unit.
7. Make sure that you install the outdoor unit in area which provides easy connection within the maximum allowable length of a coolant pipe (10 meters).
N o t e
1. Add 10 grams of refrigerant (R-22) for
every 1 meter if the pipe length exceeds the standard pipe length of 5 meters.
2. Maintain a height between the indoor and
outdoor units of less than 3 meters.
8 . Make sure that you install the outdoor unit
in an area which is large enough to accom­modate the measurements
shown in figure on the next page.
3-2-1(c) Remote Control Unit
1 . Make sure that you install the remote con-
t rol unit in an area free from obstacles such as curtains etc, which may block signals f rom the remote control unit.
2. Make sure that you install the remote con­t rol unit in an area not exposed to d i rect sunlight, and where there is no sourc e of heat.
3. Make sure that you install the remote con­t rol unit in an area away from TVs, audio units, cordless phones, fluorescent lighting f i x t u res and other electrical appliances (at least 1 meter).
Caution
It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas near machines), salty areas such as coast areas, areas where sulfuric gas is present such as hot spring areas. Contact your dealer for advice.
3-4
Samsung Electronics
3-2-2 Installation diagram of indoor unit and outdoor unit
Operating Instructions and Installation
A Indoor unit gas leak test check point
Indoor unit
Piping
1
3
2
Tape vinyl
B Drain hose installation
Cut the piping hole sloped slightly
Piping may be laid to the rear, left, right or down .
Right
Rear
Down
Remote controlRemote control holder
Rear
Left
1 2
3 4
5
Samsung Electronics
Piping (Liquid) 1/4” Clamper tube Piping (Gas) 1/2”, 3/8” Installation plate Installation tube Pipe-connection Vinyl tape Screw Putty Drain hose
6 7
8 9
10
A-UNIT
B-UNIT
Outdoor unit check point
10
3-5
Operating Instructions and Installation
3-2-2(a) Fixing the Installation Plate
(Unit : mm)
(Unit : mm)
Installation plate
280
340
Pipe hole (ø65mm)
1. Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.
2. If you are fixing the indoor unit to a… Then follow Steps…
Wall 3.
Window frame 4 to 6.
3. Fix the installation plate to the wall in a manner appro­priate to the weight of the indoor unit.
If you are mounting the plate on a concrete wall with anchor bolts, the anchor bolts must not project by more than 20mm.
4. Determine the positions of the wooden uprights to be attached to the window frame.
3-2-2(b) Purging the Unit
5. Attach the wooden uprights to the window frame in a manner appropriate to the weight of the indoor unit.
6. Using tapped screws, attach the installation plate to the wooden uprights, as illustrated in the last figure oppo­site.
On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as fol ­lows.
Unscrew the caps at the end of each pipe.
Result : All inert gas escapes from the indoor unit.
To prevent dirt or foreign objects from getting into
the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping.
3-6