SAMPI SM30 User Manual

SM30 Meter Specifications Sheet
Superior accuracy at constant flow: with all other conditions being constant, the Sampi Meter does not vary more than 0.05% in repeatability over entire range and beyond. Accuracy over the widest range of flow: the Sampi Meter has a most ideal combination of minimum seal or slippage area with lowest pressure differential across the seal. There is no metal-to-metal contact within the meter element… and no contact means no wear… no wear means no increase in clearances… no increase in clearances means no increase in slippage… and no increase in slippage means no deterioration in accuracy.
Performance
Temperature
range
°C (°F) SSU (cP) 5:1 10:1 40:1
-40 to 71
(-40 to 160)
Viscosity
range
150 to 1500000
(25 to 325000)
± 0,125%
(or better)
Linearity
± 0,22%
(or better)
Features
Flange size
Max nom.
Flow rate
Inches l/min (GPM) Bar (PSI) Kg (lbs)
4 or 3 1700 (450) 10 (143) 63,5 (138)
Working
pressure
Weight conf.
± 0,5%
(or better)
“A”
All accuracy statements based on metering solvent, approximate viscosity 1 cP.
Materials
Class Body Rotors Vanes Gaskets
1
2 6
11
Anodized aluminium Hard anodized aluminium Anodized aluminium Buna-Viton
Anodized aluminium Hard anodized aluminium Anodized aluminium Buna-Viton
Hard anodized aluminium Hard anodized aluminium Hard anodized aluminium Viton-Teflon
Anodized aluminium Anodized aluminium Anodized aluminium Teflon
Configurations
Dimensions
SAMPI spa
A unit of IDEX Corporation
Via Amerigo Vespucci, 1 55011 Altopascio (Lucca) – Italy Phone: +39 0583 24751 Fax: +39 0583 264748 www.sampi.it