Samlex America TS-1500 User Manual

TN/TS-1500
Inverter Instruction Manual
TN/TS-1500 Instruction ManualInv erter
Index
1. Safety Guid el ines
2. Introduction
.1 Features
2
2.2 Main Specificatio n
2.3 System Block Diagra m
3.1 Fron t Pan el
3.2 LED Indi cato r o n Fro nt Pane l
3.3 Fun c tion al I n dic atio n an d A larm
3.4 Rear Panel
4.
Explanation of Oper ati ng Logic
4.1
Explan ati o n of UP S Mode Co n trol Lo g ic
Explan ati o n of En ergy Sa v ing Mode Con t r ol L og ic
4.2
Initial Se tup o f TN/TS-150 0
5.
5.1 Initia l State
5.2 Initia l Se t Po int f or T ransitio n Voltages
5.3
Procedure of S et t ing Ope rat in g Mode, Ou t pu t Vol t age ,
Freq uency, and Saving Mode
5. 4 Remote Mo ni t o ri n g So ftw a re
6. Pro tection
6.1 Inpu t Pro tec tio n
6.2 Outp ut Prote ctio n
7. Ins tall atio n & Wiri ng
8. Failure C o rrection Not es
9. Warran ty
........... ...... ........................................................... ...............
............. ....................................... .......................... ...............
..... .................... ....................................... ...............
.............. .................... ......................................................
.............. .................... ......................................................
.................. ....................................... ...............
..... .................... ....................................... ..
.......................................................... ............................
.... ................... .................... ....................................... ..
............. ....................................... ..
....... ....................................... ..
.... ................... .................... ....................................... ..
............... ....................................... ..
.................................. ..
................................................ ...............
............... ....................................... ............................
.....................................
............. ....................................... ..
.............. .......................... ...............
.............. .................... .........................................
.................. ....................................... ...............
............. .................... ....................................... ..
............. ....................................... ...............
................. ..
1
1
2
2
3
3
3
4
4
5
5
6
8
9
9
9
10
12
12
12
13
14
17
17
Feb. 2013 Version 13
1. Sa fe ty Guide lines (Ple ase read thr ough th i s man ual before ass embling
TN/TS-1500)
Risk of elect r i ca l shock a n d ener gy hazard. A ll failure s should be examine d b y
th e qua lifi ed tec hnician. Ple a se do n ot rem ove the cas e of the inverter b y
yourself !
Afte r con n ec ting the AC inpu t of the inve rt er to the utility, the AC out let of the
inverter will h ave AC output even if the p o wer swi t ch o n t h e fro nt p a ne l i s i n the OFF p os i tion .
It is hi gh l y re c omm en ded to mo un t the u nit horiz on ta lly.Plea s e do not install the inverte r i n pl a c es with high mo i stu re or nea r water.Plea s e do not install the i nv e rte r in places wit h high amb i en t te m pe r atu re or
under direct sunlight.
Plea s e only con n ect batterie s with the same brand an d mod el numb er in one
batte ry b ank . Using b att e r ies from different m anufact u r er s or d i fferent capacit y is strictl y pro h i bit ed!
Nev e r all o w a spark or fla me in the vicinity of the batt er ie s be ca us e they may
generate exp los ive ga ses during no r mal ope ration.
Mak e su re the air flo w fr om the fa n is not obstru cted at bot h sides (f ron t and
back) of the in ver ter. (Ple ase allo w at least 15cm of spa ce)
Plea s e do not stack any obj ec t on the inve rter.
WARNING:
Batteries will have agin g pr oble m after years of oper at ion.
It i s su g g este d to exe cute re g ul ar bat t e r y m a i nt ena nce (e.g. every year). Once aged, the batteries should be changed by professional technician, or the failed batteries may cause fire or oth er ha zards.
Do n 't
disa ss e mble
Inve rter Inve rter
Away f ro m
moistu re
Inv erter
Aw ay from f ir e o r
h igh temp er at u re
Do n' t stack on
the inv er ter
Inverter
K eep good ve nti la tio n
2.Intro ducti o n
Fully digit al con trolled b y an advan ced CP U, T N-1 5 00 is a tru e si ne wave
inverter e quip pe d wi th an AC ch arger and solar cha r ger. It can a lso op erat e
under UPS an d Ene r g y savi n g modes. (Descript ions whi ch are high lighted
repr esen ts func tions on ly for th e TN-1500 serie s)
TS- 1 5 00 ser ies onl y poss ess the inve rter function . It u s es batteries as the in pu t
source and co nv e r ts t h e energy i n t o A C output .
TN-1 5 00 is c apabl e o f dra win g ener g y f r om solar pan e l t hus pro vide
uninterr u p te d power ( UP S mode). Besi d e s p rov iding uni nte rrupted pow er, it also has use r ad justable ene rgy sav i ng mod e. The mai n purpos es of en erg y redu ctio n and building an ind e pe nde n t su b po wer station are reali zed. We can
s a y tha t TN -1 5 0 0 se r i es is a m u l t i - fu n c t i o na l an d des i gne d to be
environm entally friendly.
1
TN- 1 5 00 s er ies will a u tom at i cally detect th e input sources ( whet he r AC main or
sola r pa n els exis t) an d then adjus t its int e rnal sett i ng. Users ca n als o s et u p the oper atin g mode, output volt a ge, frequency, a nd sav ing mode by themselves base d on thei r sp ecia l ne eds, geograp hic area, and enviro n me n tal condi tions.
With pur e s i ne wave out put , TN/TS -1 50 0 can p rov i d e 1500W continuousl y,
1750W f o r 3 min utes, or 20~40A of peak cur r en t for all ki nds of load suc h as induct ive , c a pa c i t ive, or resist i ve. Ge n e ra l app lic ations in clu d e P C, ITE , vehicl es , ya c hts , home appliances, motors, po wer too l s, industri a l con trol
equipme nts, AV s ystem, a nd etc. . .
2. 1 F e atu r es
Sele c tab le UP S or En ergy sav i ng modeTrue sine wav e ou t pu t (THD<3%)
So l ar c h ar g i ng cur r ent 3 0A maxFa st trans fe r time 10ms (Typ .)
1500 W ra ted outputHigh e fficiency up to 90%Com plete LE D ind ica t i on fo r opera ting stat usBattery low alarm and indicatorSurg e power capabili t y up to 30 00 WOut p u t vo ltage / frequ e nc y sele cta b leFully digi tal c ontrolledCom plianc e to UL
458 / FCC / E / CE
13
Can b e u sed fo r m ost of electr onic produc t s with AC inp ut3 yea r glo bal warranty
Main Specific atio n
2. 2
MODEL
Rate d po we r
Sur g e
O
Cur r en t
U
Fac t or y
T
set ting
P
Output vol tage
U
Frequency
T
WAVEFORM
PROTECTION
BAT. VO LTAGE
DC CUR RE N T
I N
EFFI CIENCY
P
OFF MODE
U
CURRENT
T
DRAW
PROTECTION CHARGE
VOLTAGE
C
AC CHARGE
H
CURRENT
A
SOLAR OPEN
R
CIRCUIT
G
VOLTAGE
E
SOLAR
R
CHARGE CURRENT
112 12 4 148 212 224 248 1500W max. continuously, 1750W max. for 180 seconds, 1875W max. for 10 seconds, 3000W for 30 cycle
    
110V 60Hz
100 / 1 10 / 115 / 120V 60 0.1 Hz±
True s ine wa v e (THD <3 .0 %) AC s h o rt O ve rload Over Tem perature
10.5 ~ 15. 0V
150 A
87%
Und er 1 .0 mA at pow er s w itch OF F
Over current battery polarity reverse by fuse battery low shutdown battery low alarm
14.5V
5.5A 0. 5A±
25Vma x
30A max.
21.0 ~ 30 .0V
75 A
89 %
29 .0V
2.7A 0.4A±
45 Vmax
42.0 ~ 60.0V
37.5A
89%
58.0V
1.35A 0.2A±
75Vma x
    
230V 5 0H z
200 / 220 / 230 / 2 4 0V 50 0.1 Hz±
10.5 ~ 15 . 0V
15 0A
88 %
14 .5 V
5. 5A 0. 5A±
25 Vm ax
21.0 ~ 30 .0V
75A
90%
29.0V
2.7A 0. 4A±
45Vm ax
42.0 ~ 60 . 0V
37 .5 A
91 %
58 .0 V
1. 35 A 0. 2A±
75 Vm ax
2
2.3 Sys te m Block Dia gram
TN-1500 Inverter
EM I
AC
In pu t
fi lt er
Sol ar P an el
Fu se
Sola r c harg er
Bat te ry
12 V/2 4V /48 V
AC ch ar ger
Fuse
Pola ri ty
dete c t
DC/ D C
Co nv ert er
CPU
Co nt roll e r
200V
LED
Disp l ay
Cir cu i t
DC
DC
/40 0V
DC/ AC
In vert e r
Bre ak er
Fig ur e 2.1 System Bloc k Dia g ra m
3.Use r interface
3.1 Fr ont Panel
A
POWE R on/of f sw itch: Th e in v erter will tu rn OFF i f the switch is i n the OFF positio n.
B
AC ou t pu t out let : To sa tisfy ap plication demand of d ifferent geograp hic a rea s all over the wo r ld, th ere are many optional A C ou t lets to ch oose fr om.
No Fuse B rea ker; Re set: Under "By pass Mode " , when the AC outp ut is
C
shorted or the load current exceeds the rated curren t of the No Fuse Breake r, the No Fuse Br e ak e r will open an d that stop s byp as sing energy fr om the utility gettin g to preve nt p oss ible dang er. Whe n th e abnormal ope ra ti n g condition is rem ove d, user c an pres s down o n th e Re set butt on to resume op e r ati on.
D
Ventilation ho les: The inverter require s su it abl e ve ntilation to w ork p ro per ly.
Ple ase ma k e s u re t her e is g ood ven t ilation a nd the lif esp an of th e inv erte r ca n pre serv ed.
E
Function Sett i ng : Operating Mod e , Outpu t vo ltag e , fre qu enc y, and saving mode c an b e set through this bu t ton . LED In dic atin g Panel: Op er a ting sta tus , loa d conditio n, and all type s of
F
warnin gs w ill be di s pla y ed on this panel .
G
Comm u nic ation P ort: For remote m onit oring purpo se, the un i t ca n b e
connected to a PC throu gh this com mun i cation po rt b y us i ng the optio n al cabl e and mo ni to ring so ftware.
12 0V/ 23 0V 50 Hz/ 60H z
LO AD
AC
Outp ut
3
B F
AC O UTPU T
A
C
ON
OFF
SOLA RCHAR GE
AC CHARGE
D
BATTERY
100
INVE RTER
0
BY PASSACI N
LOAD
1 00
0
Remote
port
Se ttin g
On
Ba tL o w
Sa vin g
E
G
Figure 3.1: F r ont Pan el (T N-1 500)
3.2 LED Indi c at o r on Front Pane l
Batter y Ca pac ity Indicator: repres e nt s the re m ai n ing ca p acit y of externa l batter i e s.
LED Display
Batte ry Capacity
LED 1 ON
LED 1~ 2 ON
LED 1 ~ 3 ON
LE D 1 ~ 4 ON
0 ~ 25% 26 ~ 50 % 51 ~ 75% 76 ~ 100%
Load C onditio n Ind ic at o r : re pre sen t s the magnitude of ou tpu t l oa ds.
LED Display
Batte ry Capacity
LED 1 ON
LED 1~ 2 ON
LED 1 ~ 3 ON
LE D 1 ~ 4 ON
0 ~ 30% 30 ~ 50% 50 ~ 75% 75 ~ 100%
3.3 Func tion Ind i ca t i on a nd Ala r m
O n :
Bat Lo w :
The inverter started up and outp u t is n or m al .
Voltag e of external bat terie s is too low. The inverter will sen d ou t
a "Beep" sound t o warn th e us ers .
S a vin g :
The inv ert e r is operati n g u n der the "Saving Mode" a nd t here's n o
AC output.
AC CH AR GE :SOLAR C HARGE :
The b u ilt-in AC cha rge r is c ha rg ing e xte rna l ba t teries.
The exte rna l sol ar pane ls are p r o vid ing ener gy t o th e
ext e r na l bat t eri e s th r oug h th e built-i n sol a r ch arg e r. AC IN: T he stat u s of utili ty is norm al.
BYPAS S: The u ni t is wor k i ng under "B ypa s s Mode". The AC el ec t r icit y
con s umed by the loa ds is provide d by th e uti lity instead of the i nv er ter.
INV ERT ER: Th e uni t is working und er "Inv e r te r Mode" The AC electrici t y
con s umed by the loa ds is con verted from the b at te ries.
BATTERY: D ispla y th e remain ing cap acity of ex ternal b atteries.
LOA D: Display t h e outpu t loa d status .
4
Loading...
+ 14 hidden pages