1.
1. Important Safety Instructions
Before using the Inverter, read and save the safety
1-1. General Safety Precautions
WARNING!
instructions.
1-1-
Do not expose the Inverter to rain, snow, spray, bilge or dust.
To reduce risk of hazard, do not cover or obstruct the ventilation
openings. Do not install the Inverter in a zero-clearance
compartment. Overheating may result.
1-1-2. To avoid a risk of fire and electronic shock. Make sure that existing
wiring is in good electrical condition; and that wire size is not
undersized.
Do not operate the Inverter with damaged or substandard wiring.
1-1-3. This equipment contains components which can produce arcs or
sparks. To prevent fire or explosion do not install in compartments
containing batteries or flammable materials or in locations which
require ignition protected equipment. This includes any space
containing gasoline-powered machinery, fuel tanks, or joints, fittings,
or other connection between components of the fuel system.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts skin or clothing, wash immediately with soap
and water. If acid enters eye, immediately flood eye with running
cold water for at least 20 minutes and get medical attention
immediately.
1-2-2. Never smoke or allow a spark or flame in vicinity of battery or
engine.
1-2-3. Do not drop a metal tool on the battery. The resulting spark or
short-circuit on the battery of other electrical part may cause an
explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces,
and watches when working with a lead-acid battery.
A lead-acid battery produces a short-circuit current high enough to
weld a ring or the like to metal, causing a severe burn.
3
The following two separate optional versions of these units are available
loads and the inverter will remain in the standby condition. If AC input
ain be transferred back to the
2. Functional Characteristics
2-1. General Information
ST-series consist of a stand–alone power inverter with built-in AC
Transfer
Switch and is suitable for RV, Marine and Emergency applications.
(These are required to be ordered separately) :
Option 1
•
Off-line Mode
source and the DC to AC inverter is the backup source. If AC input
power from the utility is available, it will be passed through to the AC
: The AC input power from the utility is the primary
Option 2
power from the utility fails, the AC loads will be transferred to the
inverter. When AC input power from the utility returns, the load will
once again be transferred back to the utility and the inverter will once
again remain in standby condition. This is the standard version.
•
On-line Mode
: The AC power from the DC to AC inverter is the
primary AC power source and the utility AC power is the backup
source. If the DC source or the inverter fail, AC input power from the
utility will be passed through to the AC loads. Once the DC power
source is restored, the load will once ag
inverter. This is an optional version and has to be ordered
specifically.
WARNING!
The above two option are fixed during the production and
customer unable to modify.
4
2-2. Application
2-2-1
Power tools–circular saws, drills, grinders, sanders, buffers, weed and
hedge trimmers, air compressors.