Samlex America ST1500-148 User Manual

ST Series
Pure Sine Wave
Power Inverter
User ’s Manual
1
Contents
1. Important Safety Instructions……………………………………………………………………. 2
1-1 General safety precautions…………………………………………………………………… 2
1-2 Precautions when working with Batteries…………………………………………………… 2
2. Functional Characteristics.………………………………………………………………………. 3
2-1 General Information…………………………………………………………………………. 3
2-2 Application……………………………………………………………………………………. 4
2-3 Features………………………………………………………………………………………. 5
2-4 Electrical Performance………………………………………………………………………. 6
2-5 Mechanical drawings………………………………………………………………………... 10
3. Introduction.………………………………………………………………………………………… 12
3-1 Front Panel Operation………………………………………………………………………. 12
3-2 Protections Features………………………………………………………………………... 16
3-3 DC Wiring Connections.………….…………………………………………………………. 16
3-4 Hard-wire Installation….………….…………………………………………………………. 20
3-5 Rear panel Operation……………………………………………………………………….. 23
3-6 Installation……………………………………………………………………………………. 23
3-7 Inverter Operation…………………………………………………………………………… 24
4 Information………………………………………………………………………………………….. 25
4-1 Troubleshooting…………………….……………………………….…………………………. 25
4-2 Maintenance………………………………………………………..………………………….. 25
4-3 Warranty………………………………………………………………………………………... 26
5. Appendices………………………………………………………………………………………….. 27
5-1 FCC (Class A) Declaration of Conformity………………………………………………… 27
5-2 e-mark (e13) Declaration of Conformity………………………………………………….. 29
5-3 EMC (Class A) Declaration of Conformity………………………………………............. 36
5-4 CE (LVD EN60950) Declaration of Conformity…………………………………………... 38
©Copyright: This manual is the copyright of COTEK Electronic Ind. Co., Ltd. And may not be
reproduced or copied without the express permission of the owner.
2
1.
1. Important Safety Instructions
Before using the Inverter, read and save the safety
1-1. General Safety Precautions
WARNING!
instructions.
1-1-
Do not expose the Inverter to rain, snow, spray, bilge or dust. To reduce risk of hazard, do not cover or obstruct the ventilation openings. Do not install the Inverter in a zero-clearance compartment. Overheating may result.
1-1-2. To avoid a risk of fire and electronic shock. Make sure that existing
wiring is in good electrical condition; and that wire size is not undersized. Do not operate the Inverter with damaged or substandard wiring.
1-1-3. This equipment contains components which can produce arcs or
sparks. To prevent fire or explosion do not install in compartments containing batteries or flammable materials or in locations which require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts skin or clothing, wash immediately with soap
and water. If acid enters eye, immediately flood eye with running cold water for at least 20 minutes and get medical attention immediately.
1-2-2. Never smoke or allow a spark or flame in vicinity of battery or
engine.
1-2-3. Do not drop a metal tool on the battery. The resulting spark or
short-circuit on the battery of other electrical part may cause an explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces,
and watches when working with a lead-acid battery. A lead-acid battery produces a short-circuit current high enough to weld a ring or the like to metal, causing a severe burn.
3
The following two separate optional versions of these units are available
loads and the inverter will remain in the standby condition. If AC input
ain be transferred back to the
2. Functional Characteristics
2-1. General Information
ST-series consist of a stand–alone power inverter with built-in AC Transfer Switch and is suitable for RV, Marine and Emergency applications.
(These are required to be ordered separately) :
Option 1
Off-line Mode
source and the DC to AC inverter is the backup source. If AC input power from the utility is available, it will be passed through to the AC
: The AC input power from the utility is the primary
Option 2
power from the utility fails, the AC loads will be transferred to the inverter. When AC input power from the utility returns, the load will once again be transferred back to the utility and the inverter will once again remain in standby condition. This is the standard version.
On-line Mode
: The AC power from the DC to AC inverter is the
primary AC power source and the utility AC power is the backup source. If the DC source or the inverter fail, AC input power from the utility will be passed through to the AC loads. Once the DC power source is restored, the load will once ag inverter. This is an optional version and has to be ordered specifically.
WARNING!
The above two option are fixed during the production and customer unable to modify.
4
2-2. Application
2-2-1
Power tools–circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors.
2-2-2.
Office equipment – computers, printers, monitors, facsimile machines, scanners.
2-2-3.
Household items – vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines.
2-2-4.
2-2-5
2-2-6.
Kitchen appliances – coffee makers, blenders, ice markers, toasters.
Industrial equipment – metal halide lamp, high – pressure sodium lamp.
Home entertainment electronics – television, VCRs, video games, stereos, musical instruments, satellite equipment.
5
2-3. Features
Pure sine wave output (THD < 3%) to operate higher-end electronic Equipments.
■ 3 LED indicators with tri-color display all operation status.
■ High efficiency 88 ~ 94%.
Output frequency50 / 60Hz switch selectable
Built in 16A/25A or 30A rating transfer switch.
Speed up transfer time and synchronized operation with the AC source at all times that allows the transfer to be interruption-free for sensitive
equipments.
Built in advance microprocessor to make friendly interface with user.
Low power “ Power Saving Mode “ to conserve energy
Capable of driving highly reactive & capacitive loads at start moment.
Hardwire AC connection model option.
Loading controlled cooling fan.
Smart remote controller.
Protection:
Input over voltage and Input low voltage protection.
Low battery alarm
Over temperature protection.
Over load protection
Short Circuit protection
Reverse polarity protection.
AC circuit breaker (6Amp to 30Amp)
6
10.5-15
21.0-30
42.0-60
10.5-15
21.0-30
42.0-60
2-4. Electrical Performance
Specification Model No.
Item
ST1000-112 ST1000-124 ST1000-148 ST1000-212 ST1000-224 ST1000-248
Continuous Output Power 1000W
Maximum Output Power (3Min.)
1150W
Surge Rating 2000W
Input Voltage 12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V ± 5% 220 / 230 / 240V ± 3%
Frequency
50 / 60Hz
(Switch Selectable)
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 88% 90% 92% 90% 93% 94%
No Load Current Draw 1.43A 0.75A 0.38A 1.25A 0.65A 0.35A
Stand-By Current Draw 0.25A 0.15A 0.09A 0.25A 0.15A 0.09A
Input Voltage Regulation
VDC
VDC
VDC
VDC
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
VDC
Failure Indicator Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker 30 Amp 6 Amp
Remote Control Unit CR6 / CR8 Optional
Synchronous AC transfer YES
Transfer switch 30 Amp 16 Amp
Transfer Time Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety Meet UL458 ------
EMI Conduction&Radiation Compliance to FCC Class A Compliance to EN55022 classA
EMS Immunity ------ Compliance to EN61000-3-2,3
EMC
Operating Temperature Range
Storage Temperature Range
LVD ------ Compliance to EN60950-1
e-MARK ------ Compliance to e-13*72/245/ECC,95/54 EC
0 – 40
-30
to 70
Cooling Loading controlled cooling fan
Dimensions 373(L)*236(W)*115(H) mm / 14.7(L)*9.29(W)*4.53(H) Inch
Weight 6.2 kg / 13.6 Lbs.
Note: The specifications are subject to change without notice.
7
10.5-15
21.0-30
42.0-60
10.5-15
21.0-30
42.0-60
2-4. Electrical Performance
Specification Model No.
Item
ST1500-112 ST1500-124 ST1500-148 ST1500-212 ST1500-224 ST1500-248
Continuous Output Power 1500W
Maximum Output Power (3Min.)
1725W
Surge Rating 3000W
Input Voltage 12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V ± 5% 220 / 230 / 240V ± 3%
Frequency
50 / 60Hz
(Switch Selectable)
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 88% 91% 92% 92% 93% 94%
No Load Current Draw 1.45A 0.75A 0.40A 1.40A 0.70A 0.40A
Stand-By Current Draw 0.28A 0.15A 0.09A 0.28A 0.15A 0.09A
Input Voltage Regulation
VDC
VDC
VDC
VDC
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
VDC
Failure Indicator Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker 30 Amp 10 Amp
Remote Control Unit CR6 / CR8 Optional
Synchronous AC transfer YES
Transfer switch 30 Amp 10Amp
Transfer Time Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety Meet UL458 ------
EMI Conduction&Radiation Compliance to FCC Class A Compliance to EN55022 classA
EMS Immunity ------ Compliance to EN61000-3-2,3
EMC
Operating Temperature Range
Storage Temperature Range
LVD ------ Compliance to EN60950-1
e-MARK ------ Compliance to e-13*72/245/ECC,95/54 EC
0 - 40
-30
to 70
Cooling Loading controlled cooling fan
Dimensions 403(L)*236(W)*115(H) mm / 15.9(L)*9.29(W)*4.53(H) Inch
Weight 7.0 kg / 15.4 Lbs.
Note: The specifications are subject to change without notice.
8
10.5-15
21.0-30
42.0-60
10.5-15
21.0-30
42.0-60
2-4. Electrical Performance
Specification Model No.
Item
ST2000-112 ST2000-124 ST2000-148 ST2000-212 ST2000-224 ST2000-248
Continuous Output Power 2000W
Maximum Output Power (3Min.)
2300W
Surge Rating 4000W
Input Voltage 12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V ± 5% 220 / 230 / 240V ± 3%
Frequency
50 / 60Hz
(Switch Selectable)
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 88% 91% 92% 90% 93% 94%
No Load Current Draw 2.6A 1.50A 0.70A 2.3A 1.1A 0.65A
Stand-By Current Draw 0.60A 0.30A 0.2A 0.60A 0.3A 0.15A
Input Voltage Regulation
VDC
VDC
VDC
VDC
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
VDC
Failure Indicator Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker 30Amp
Remote Control Unit CR6 / CR8 Optional
Synchronous AC transfer YES
Transfer switch 30Amp 25 Amp
Transfer Time Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety Meet UL458 ------
EMI Conduction&Radiation Compliance to FCC Class A Compliance to EN55022 classA
EMS Immunity ------ Compliance to EN61000-3-2,3
EMC
Operating Temperature Range
Storage Temperature Range
LVD ------ Compliance to EN60950-1
e-MARK ------ Compliance to e-13*72/245/ECC,95/54 EC
0 - 40
-30
to 70
Cooling Loading controlled cooling fan
Dimensions 433(L)*332(W)*115(H) mm / 17(L)*13(W)*4.53(H) Inch
Weight 11.2 kg / 24.6 Lbs.
Note: The specifications are subject to change without notice.
9
10.5-15
21.0-30
42.0-60
10.5-15
21.0-30
42.0-60
2-4. Electrical Performance
Specification Model No.
Item
ST2500-112 ST2500-124 ST2500-148 ST2500-212 ST2500-224 ST2500-248
Continuous Output Power 2500W
Maximum Output Power (3Min.)
2875W
Surge Rating 5000W
Input Voltage 12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V ± 5% 220 / 230 / 240V ± 3%
Frequency
50 / 60Hz
(Switch Selectable)
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 88% 91% 92% 90% 93% 94%
No Load Current Draw 2.62A 1.53A 0.72A 2.32A 1.15A 0.68A
Stand-By Current Draw 0.60A 0.30A 0.2A 0.60A 0.3A 0.15A
Input Voltage Regulation
VDC
VDC
VDC
VDC
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
VDC
Failure Indicator Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker 30 Amp
Remote Control Unit CR6 / CR8 Optional
Synchronous AC transfer YES
Transfer switch 30Amp 25 Amp
Transfer Time Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety Meet UL458 ------
EMI Conduction&Radiation Compliance to FCC Class A Compliance to EN55022 classA
EMS Immunity ------ Compliance to EN61000-3-2,3
EMC
Operating Temperature Range
Storage Temperature Range
LVD ------ Compliance to EN60950-1
e-MARK ------ Compliance to e-13*72/245/ECC,95/54 EC
0 - 40
-30
to 70
Cooling Loading controlled cooling fan
Dimensions 463(L)*332(W)*115(H) mm / 18.2(L)*13(W)*4.53(H) Inch
Weight 12 kg / 26.4 Lbs.
Note: The specifications are subject to change without notice.
2-5. Mechanical drawings
GND
ENB
ENB
INPUT
LEVEL
REMOTE
PORT
POWER
ON-OFF-REMOTE
DC INPUT
POS(+)NEG(-)
REVERSE POLARITY WILL DAMAGE UNIT
AC INPUT
BREAKER
S S S S
1 2 3 4 0
1
POWER
LOAD
LEVEL
STATUS
PWR.
FREQ.
SAV.
10
2-5. Mechanical drawings
GND
ENB
ENB
INPUT
LEVEL
REMOTE
PORT
POWER
ON-OFF-REMOTE
DC INPUT
NEG(-)
WARNING:
REVERSE POLARITY WILL DAMAGE UNIT
POS(+)NEG(-)
POS(+)
AC INPUT
BREAKER
S S S S
1 2 3 4 0
1
POWER
LOAD
LEVEL
STATUS
PWR.
FREQ.
SAV.
11
Loading...
+ 28 hidden pages