Samlex America SEC-1245A User Manual

SAMLEX AMERICA
.
SAMLEX AMERICA
.
TECHNICAL DATA
AUTOMATIC BATTERY CHARGER
Model Number SEC-1245A SEC-2425A
Mains input voltage range 115V±10% 115V±10%
Mains frequency 50-60Hz 50-60Hz
0
Boost voltage (UO-phase) at 20
Float voltage (U-phase) at 20
C 14.4V 28.8V
0
C 13.8V 27.6V
Max. charging current (I-phase) 45A 25A
Operating temperature range 0
0
-500 C0
0
-500 C
Weight 5 kg 5 kg
Housing dimensions (wxhxd) 230x108x305mm 230x108x305mm
Optional accessory Temperature sensor (Part No. TF-500)
NOTE: Above ratings are subject to change without notice or obligation due to advancements in technology.
AUTOMATIC BATTERY CHARGER
MODELS: SEC-1245A
SEC-2425A
Version # 121000
.
SAMLEX AMERICA
SAMLEX AMERICA
.
110-17 Fawcett Road, Coquitlam
B.C., Canada V3K 6V2
e-mail: samlex@samlexamerica.com
website: www.samlexamerica.com
7
WITH IUOU CHARACTERISTICS
OWNER'S MANUAL
Please read this manual before operating your charger.
Samlex America Inc.
Automatic Battery Charger
CONTENTS
READ THESE INSTALLATION AND OPERATING INSTRUCTIONS BEFORE CONNECTING AND USING THE IUOU CHARGER:
Information on caution and warning signs 1
General safety and installation information 1-2
Intended use 2
Installation and putting into operation 3-4
Temperature sensor 5
Rectifier function 6
Charging 6
Technical data 7
RECTIFIER FUNCTION
The IUOU charger can be used as a 12V/24V mains unit
provided that the maximum current consumption of the
consumers does not exceed the rated current of the charger. It
is recommended to have battery connected (Fig. 2) in any
case. The consumers should be connected directly to the battery.
This applies in particular to consumers with high peak
currents (e.g. high start-up current in the case of compressors).
In parallel operation (consumers and battery), the maximum
consumer current should be less than the rated current of the
charger because otherwise the battery will discharge.
Maximum current consumption of consumers when used as a
mains unit (Fig 1).
INFORMATION ON CAUTION & WARNING SIGNS
Warning! Safety warning: Failure to observe this warning may result in injury to
persons and damage to equipment.
Caution! Safety warning: Failure to observe this warning may result in damage to
!
equipment and improper functioning of the IUOU charger.
GENERAL SAFETY AND INSTALLATION INFORMATION
Warning! The following fundamental safety measures must
be observed when using electrical equipment to avoid the
danger of: electric shocks
fire
injury
ABOUT THE UNIT ITSELF
The IUOU charger may only be used for the purpose specified by
the manufacturer!
When working on the IUOU charger, always disconnect from the mains!
Do not operate the IUOU charger if the housing or cables are
damaged!
The IUOU charger must be positioned and fixed in such a way
that it cannot fall over or fall down!
The IUOU charger may only be connected to earthed sockets!
Ensure good ventilation.
The IUOU charger must be kept in a safe place out of the reach of
children!
Warning! Protect and always operate the 115V connection
of the IUOU charger via a GFCI (Ground Fault Circuit
Interrupter) of 30mA fault current.
The IUOU charger may not be operated in damp or wet environment!
Servicing and repair may only be carried out by skilled personnel
being familiar with the risks involved and the relevant regulations!
CAUTION FOR INSTALLATION ON BOATS!
Wrong installation of electrical units on a boat may
lead to corrosion of the boat. Therefore, please let a
(boat) electrician carry out the installation of the charger.
SEC-1245A = max. 45 Ampere
SEC-2425A = max. 25 Ampere
CHARGING
The 3 phase IUOU charge characteristic guarantees
rapid, complete and at the same time gentle charging
of the battery.
Stage 1: THE I-PHASE. The battery is charged at
constant current (45A for SEC-1245A or 25A for SEC-
2425A) until it approaches the float voltage. The
control LED glows red. The output voltage is
determined by the battery voltage.
Stage 2: UO-PHASE. On reaching 80% of the max.
rated current, the charging takes place at a constant
Boost Voltage of 14.4V (SEC-1445A) or 28.8V (SEC-
2425A). The charger remains in this stage until the
current reduces to 10% of the max. rated current or 2
hours, whichever is earlier. The control LED glows yellow.
Stage 3: U-PHASE. After the UO-phase, the charging
voltage switches over to floating voltage (13.8V for
SEC-1245A and 27.6 for SEC-2425A). In this phase, the
battery is practically at rest and only takes the current
necessary for maintaining the capacity. The LED light
is green.
If a load is connected to the battery in this phase, it is
possible that the charger switches back to the UO-phase
until the 2 hour time limit is reached. Otherwise it
remains in this U-phase.
CAUTION!
Batteries with a cell closure may not be charged,
as there is the danger of explosion by occurrence
of electrolytic gas.
Ni-Cd batteries and non-rechargeable batteries
may not be charged. The casing of these batteries
can burst by explosion.
1
6
Loading...