SECTION 1
Important Safety Instructions ................................................ 3
SECTION 2
Layout ........................................................................... 4
SECTION 3
Introduction ...........................................................................5
SECTION 4
How Your Inverter Works ..................................................... 6
SECTION 5
Installation - DC Input Power Source,
Grounding & Mounting ....................................................... 7
SECTION 6
Input, Output Connections & Operation .............................. 8
SECTION 7
Protective Features of the Inverter ...................................... 10
SECTION 8
Common Problems ............................................................ 11
SECTION 9
Trouble Shooting Guide ..................................................... 12
SECTION 10
Specications ......................................................................14
SECTION 11
Warranty ........................................................................ 15
2 | SAMLEX AMERICA INC.
SECTION 1 | Important Safety Instructions
To ensure reliable service, your power inverter must be installed and used properly. Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the WARNING and CAUTION statements in this manual.
The CAUTION statements advise against certain conditions and practices that may result in damage to your inverter. The WARNING statements identify conditions or practices that may result in personal injury. Read All Instructions Before Using
This Power Inverter!
WARNINGS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY
1. Do not connect to AC distribution wiring.
2. Remove appliance plug from outlet strip or turn off inverter before working on the appliance.
Multiple outlet power strips with
switches and circuit breakers interrupt power only to the “hot” receptacle ter­minals. The “neutral” terminals remain powered with respect to the“ground” terminals.
3. Do not make any electrical connections or disconnections in areas designatedas IGNITION PROTECTED. This includes 12 VDC cigarette plug connections, and terminal connections.
4. This is not a toy - keep away from children.
5. DO NOT insert objects into air vents.
CAUTIONS
!
1. Do not use with positive ground electrical systems (the majority of modern automobiles, RVs, trucks and boats are negative ground). Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter.
2. This inverter will not operate high wattage appliances over the output power limit or surge power limit.
3. Grounding the neutral will cause the inverter to shut down. Do not operate this inverter if it is wet. Do not install in engine compartment – please install in a well ventilated area.
4. This inverter is not tested for use with medical devices.
IMPORTANT CABLE INFORMATION
Substantial power loss and reduced bat­tery operating time results from inverters installed with cables that are not able to supply full power. Symptoms of low bat­tery power can result from cables that are either excessively long or an insufcient gauge. The installer/operator should be especially aware of the requirements to maintain SECURE, TIGHT, WATER-RESIST­ANT electrical connections and to provide for strain relief for DC cables and appli­ance wiring. Cable insulation must be the appropriate type for the environment.
SECTION 2 | Layout: SAM-450-12E
Front Panel
2
6
Back Panel
7
8*
Front Panel
1. Universal AC output receptacle 1A - Current carrying prong 1B - Current carrying prong 1C - Grounding prong
2. ON/OFF Switch
3. RED LED - “Fault”
4. GREEN LED - “Power”
5. YELLOW LED - “Input Fault”
6. USB port
1A
1B
1C
1
9
Accessories
10. Battery input cable set with battery clamps
11. Battery input cable set with cigar plug
3 4
5
10
Rear Panel
7. Red Thumb Screw (M4 size) for Positive (+) battery input terminal
8. Black Thumb Screw (M4 size) for Negative (-) battery input terminal.
NOTE: The Negative terminal is internally
*
bonded to the metal chassis of the inverter.
9. Opening for cooling fan discharge
Figure: SAM-450-12E Front & Back Panel Layout & Accessories
4 | SAMLEX AMERICA INC.
11
SECTION 3 | Introduction
Your new SAM Series power inverter is one in a series of the most advanced DC to AC inverters available today. With proper care and appropriate usage, it will give you years of dependable service in your car, truck, RV or boat.
SAM Series inverters designed with a universal protection circuit that provide added safety features include automatic shutdown, earth fault protection and a low battery alarm to prevent damage to your battery.
This power inverter is congured with the latest low interference technology (L.I.T.), Universal Protection Circuit (UP-Circuit) and Soft Start circuit to improve inverter operation.
UP-Circuit Provides full automatic inverter and bat­tery protection. This includes overheat protection, battery protection, overload protection, short circuit protection and earth fault protection.
L.I.T. Greatly improve the interference prob­lems of common power inverter. Before introduction of L.I.T., signal interference may occur on TV pictures, audio system or radio equipments. Now you can enjoy a clean and powerful AC source!
Soft Start Circuit
Provides three major features. First, gradual voltage ramp-up during inverter start-up. This eliminates failed cold starts under load. Second, output that momen­tarily dips in voltage and quickly recovers. This eliminates most shutdowns from momentary overloads.
Load Controlled Cooling Fan
The fan will switch on automatically when the load > 8 to 12W and switch off when load drops below 8 to 12W.
USB Charging Port
A USB charging port rated at 5V, 500 mA is provided for charging devices provided with USB charging facility.