3. Introduction…………………………………………………………………… 7
3-1 Front Panel operation….……………………………………………... 7~10
3-2 Rear Panel operation.………………………………………………… 11~12
3-3 Protections Features……………………………………………………12
3-4 Installation………………………………………………………………. 13
3-5 Making DC Wiring Connections ……………………………………... 14~16
3-6 AC Safety Grounding………………………………………………….. 17
3-7 Inverter Operation……………………………………………………… 18
4. Troubleshooting guide……………………………………………………… 19
5. Maintenance……………………………………………………………………20
6. Warranty……………………………………………………………………….. 20
1. Important Safety Instructions
WARNING!
Before using the Inverter, read and save the safety
instructions.
1-1. General Safety Precautions
1-1-1. Do not expose the Inverter to rain, snow, spray, bilge or dust.
To reduce risk of hazard, do not cover or obstruct the ventilation
openings. Do not install the Inverter in a zero-clearance compartment.
Overheating may result.
1-1-2. To avoid a risk of fire and electronic shock, make sure that existing
wiring is in good electrical condition and not undersized.
Do not operate the Inverter with damaged or substandard Wiring.
1
1-1-3. There are some components in the inverter can cause arcs and sparks.
To prevent from fire or explosion, do not put batteries, flammable
materials, or anything should be ignition–protected around the inverter.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts skin or clothing, you shall wash it out with soap
and water immediately. If battery acid contacts your eyes, you shall
wash it out with cold running water for at least 20 minutes and get
medical attention immediately.
1-2-2. Never smoke or make a spark or flame in the vicinity of the battery or
the engine.
1-2-3. Do not drop a metal tool on the battery. The resulting spark or
short-circuit on the battery of other electrical part may cause an
explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces,
and watches when operating with a lead-acid batteries.
Doing so may cause short circuit and very high temperature, which can
melt metal items and even burn you.
1
2. Features
Pure sine wave output (THD < 3%)
Output frequency:50 / 60Hz switch selections
Input & output fully isolated design
Power Saving Mode to conserve energy
High efficiency 89~94%
Driving highly reactive & capacitive loads at start moment
Tri-Color indicators show input voltage & output load level
Loading controlled cooling fan
Advanced microprocessor
Protection:Input low voltage Overload Short circuit
Low battery alarm Input over voltage Over temperature