Samlex America SA-300 User Manual

SA-150, SA-300 Series
Pure Sine Wave Inverter
User’s Manual
List of contents
1. IMPORTANT safety Information…………………………………………... 1
1-1 General Safety Precautions………………………………………….. 1
1-2 Battery Precautions…………………………………………………… 1
2. Features………………………………………………………………………. 2
2-3 Mechanical Drawing 150W………………………………………….. 4
2-4 Mechanical Drawing 300W………………………………………….. 5
3. Instructions………………………………………………………………….. 6
3-1 Front Panel Operation……………………………………………….. 6
3-2 Rear Panel Operation………………………………………………... 6
3-3 AC Safety Grounding………………………………………………… 7
3-4 Installation…………………………………………………………….. 8
3-5 DC Input (Outlet sockets available)………………………………… 9
3-6 AC Output (Outlet sockets available)………………………………. 9
3-7 ON / OFF / REMOTE Main Switch.………………………………… 10
4. Troubleshooting……………………………………………………………. 11
5. Maintenance………………………………………………………………… 12
6. Warranty…………………………………………………………………….. 12
1
1. Important Safety Information
WARNING!
Before installing and using the Inverter, you need to read
following safety information carefully.
1-1. General Safety Precautions
1-1-1. Do not expose the Inverter to water, mist, snow, or dust. To reduce the
risk of hazard, do not cover or obstruct the ventilation shaft. Do not install the Inverter in a zero-clearance compartment. Overheating may occur.
1-1-2. To avoid the risk of fire and electronic shock, make sure that existing
wiring is in good electrical condition and not undersize. Do not operate the Inverter with damaged or substandard Wiring.
1-1-3. There are some components in the inverter can cause arcs and sparks.
To prevent from fire or explosion, do not put batteries, flammable materials, or anything should be ignition–protected around the inverter.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts your skin or clothing, you need to wash it out
immediately with soap and water. If acid enters into your eyes, immediately flush your eyes with running cold water for at least 20 minutes and get medical attention immediately.
1-2-2. Never smoke or make a spark or flame in the vicinity of batteries or
Engines.
1-2-3. Do not drop a metal tools on the battery. The resulting spark or short-
circuit on the battery or other electrical parts may cause an explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces, and
watches when working with a lead-acid battery, A lead-acid battery may produce a short-circuit current who’s temperature is high enough to weld these metal items and cause a
severe burn.
1
2. Features
2-1. Electrical Performance 150W
Specification
Model No.
Item SA-150-112 SA-150-124
Continuous Output Power 150W
Surge Rating 200W
Input voltage 12V 24V
Input voltage Range 10.5 – 15.0 21.0 – 30.0
Output Voltage
110VAC
±5%
Frequency
50 / 60Hz
±0.3%
Max. Efficiency 87% 88%
No Load Current Draw <0.3A
Output Waveform Pure Sine Wave ( THD 6.0% Typical )
Power Factor Allowed
cosθ
-90° ~ cosθ+90°
Protection
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
Remote Control Yes, On/Off controlled by external switch
Safety Certification UL458 EN60950-1
EMC FCC Class B
EN55022:1997
EN61000-3-2:1998
EN61000-3-3:1995
EN55024:2001
Operating Temperature
0 – 40
Storage Temperature
-30
to 70
Fan Cooling Thermostatically controlled
Dimensions 200(L) x 132(w) x 72(H) mm / 7.87(L) x 5.20(W) x 2.83(H) Inch
Weight 2.7 kg / 5.4 Lbs.
Note: The specifications are subject to change without notice.
2
2-2. Electrical Performance 300W
Specification
Model No.
Item SA-300-112 SA-300-124
Continuous Output Power 300W
Surge Rating 400W
Input voltage 12V 24V
Input voltage Range 10.5 – 15.0 21.0 – 30.0
Output Voltage
110VAC
±5%
Frequency
50 / 60Hz
±0.3%
Max. Efficiency 89% 89%
No Load Current Draw <0.35A
Output Waveform Pure Sine Wave ( THD 6.0% Typical )
Power Factor Allowed
cosθ
-90° ~ cosθ+90°
Protection
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
Remote Control Yes, On/Off controlled by external switch
Safety Certification UL458 EN60950-1
EMC FCC Class B
EN55022:1997
EN61000-3-2:1998
EN61000-3-3:1995
EN55024:2001
Operating Temperature
0 – 40
Storage Temperature
-30
to 70
Fan Cooling Thermostatically controlled
Dimensions 237(L) x 155(w) x 72(H) mm / 9.33(L) x 6.10(W) x 2.83(H) Inch
Weight 3.5 kg / 7.7 Lbs.
Note: The specifications are subject to change without notice.
3
Loading...
+ 10 hidden pages