SAMES SA2030 Datasheet

sames
FEATURES
SA2030
SA2030
PCM FRAME ALIGNER
n Frame Alignment Recovery and loss
in accordance with CCITT recommendations G.732 and G.737
n Jitter and phase-wander immunity
exceed the requirements of CCITT recommendation G.823.
n Internal 1½ frame elastic buffer. n Detection of incoming Alarm-
Indication of Slip, loss of frame
n
synchronisation, and loss of route clock conditions.
n ISO-CMOS technology, TTL
Compatible.
n Pin-for-Pin replacement for Siemens
PEB 2030 and SM 300
n Microprocessor Interface
Indication-Signal (AIS), and Distant Alarm
APPLICATIONS
n Delay compensation and clock
alignment between 2,048MHz PCM­30 transmission lines, and terminating equipment.
n Control of Jitter and Wander within
Digital Networks.
n Delay compensation between switching
stages.
n Interfacing of PCM systems operating
with different clocks.
n PCM concentrators and subscriber
GENERAL DESCRIPTION
The SA2030 is designed to interface PCM-30 routes with switching systems. The device synchronises with the frame-format of the incoming data, and outputs this data in accordance with the bit and frame timing of the terminating equipment. The circuit is designed to tolerate delay, drift, wander and jitter of the incoming data and clock, and thus simplifies the design of data- and clock-recovery hardware. The internal 1½ frames elastic buffer provides for delay compensation and wander immunity. If the bounds of the buffer are exceeded, the SA2030 will either repeat or drop a frame. The circuit will accurately detect incoming Alarm-Indication-Signal (AIS) conditions, in accordance with CCITT recommendation G.737. Loss of frame alignment is indicated on both dedicated outputs and by outputting of AIS. The circuit includes a bidirectional alarm port for interrogation of alarm conditions.
1/12
20.01.93
M74-1885
sames
SA2030
PIN CONFIGURATION
BLOCK DIAGRAM
2/12
sames
SA2030
FUNCTIONAL DESCRIPTION PCM INPUT AND FRAME-ALIGNMENT
The SA2030 accepts route data on the IN input pin, on rising edges of the route clock RCL. The circuit synchronises with the frame format of the incoming data by identification of the Frame Alignment Signal (FAS) and the Service Word (SW) in time slot zero of the PCM frame. The algorithm used for recovery and loss of frame synchronisation is in accordance with CCITT recommendation G.737. After the circuit has gained synchronisation with the incoming PCM-30 data stream, it outputs a synchronisation pulse SP on alternate frames, during the bit interval prior to time-slot-zero of frames containing the FAS word. The circuit will output a fault pulse on the FP output every time errors are detected in the incoming FAS word. When the circuit is unable to synchronise with the incoming data format, the SA2030 will generate a fault pulse every alternate frame, and outgoing synchronisation pulses will be suppressed.
PCM OUTPUT
Data is clocked out on falling edges of the System Clock (SCL). PCM output is clocked out serially on the SO output, and is made available in parallel on a tristate bus with parity (B1-B8, P). The tristate outputs are enabled by asserting CE. The SA2030 must be provided with a System Clock Trigger (SCT) pulse to define the required output frame timing. The SCT pulse defines the bit interval immediately prior to the start of time-slot­zero, on every alternate frame. Acceptance of SCT pulses is only enabled when CE is asserted. The tristate parallel bus, with CE control, simplifies the use of the circuit in multiplex and switching applications.
ELASTIC BUFFER
Incoming PCM data is saved in dual-ported RAM. The RAM has capacity for 1½ frames of data. The SA2030 can thus accommodate any required frame delay between the incoming data timing, and the required output frame timing. When the bounds of the buffer are exceeded, whole frames are either dropped or repeated. The action of dropping or repeating a received frame is called slip. Depending on the frame-delay, the SA2030 can tolerate between ½ and 1½ frame of wander without requiring to alternately repeat and drop frames. The design of the elastic buffer controller provides for correct performance under severe clock-and-data-jitter conditions. The SA2030 exceeds the requirements of CCITT recommendation G.823, and can be used to control jitter and wander within digital networks. The 1½ frame buffer is enabled by setting BI = 0. If BI = 1, the buffer length is limited to only one frame. The frame delay through the frame­aligner is then constrained to be less than one frame. The buffer inhibit mode is useful for delay compensation within a switching system, where drift and wander do not occur.
sames
3/12
SA2030
ALARM SUBSYSTEM
The alarm system may be used by the host equipment to determine the operation status of the SA2030. The SA2030 provides a bidirectional alarm-port interface DB1 and DB2. The direction of the interface is controlled by the R/W line. Transfers to or from the interface are enabled by strobing the port-enable (PE) input. The circuit includes two 2­bit alarm registers. The four flags in these registers are set when:
- Incoming Alarm-Indication-Signal is received (AIS)
- Loss of frame synchronisation occurs (SYLOSS)
- A distant alarm is received (DISAL)
- A frame slip occurs (SLIP) * The algorithm used for detection of incoming AIS is in accordance with CCITT
recommendation G.737. That is, AIS will be correctly detected, even in the presence of random errors, at a rate of 1 in 103.
* The loss of frame synchronisation flag is set if loss of frame-alignment occurs, if the
route clock is missing or too slow, or if a system-clock-trigger (SCT) pulse is not applied to the circuit once every alternate frame.
* The distant alarm flag is set if bit 3 of time-slot-zero of frames not containing FAS
is true.
* The frame-slip is set if the frame aligner either drops or repeats a frame. Selection of which of the two alarm registers is to be read, is carried out by first writing
a command to the comand register via DB1 and DB2. Four commands are supported:
- Enable Read of Alarm Group 1
- Enable Read of Alarm Group 2
- Clear all alarm flags
- Simulate Alarms Alarm Group 1 includes the AIS and frame synchronisation flags. Alarm Group 2 includes
the Slip and distant alarm flags. Once an alarm flag is set, it can only be cleared by writing the "clear-all-alarms" command
to the alarm command register. That is, these flags remain set until explicitly cleared. The simulate-alarm command provides an alarm system self-test capability. This command simulates all alarm conditions at their sources. If the circuit is operating correctly, all alarm flags should be set after issuing this command. Alarm simulation tests the loss of synchronisation function of the frame alignment state-machine, and the AIS detection logic, and thus may require up to four-frames to complete. After all of the alarm flags are set, alarm simulation is disabled, and the circuit reverts to normal operation.
4/12
sames