Samcon ExCam niteZoom User Manual

ExCam® niteZoom
User manual
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 2 of 24
Content
1 Document overview ................................................................................................. 4
2 Technical Data ................................ ................................ ................................ .......... 5
2.1 Parameters of the explosion protection ............................................................... 5
2.2 Electrical parameters ........................................................................................... 5
2.3 System cable SKAxx ........................................................................................... 5
2.4 Mechanical parameters ....................................................................................... 6
2.5 Temperature range .............................................................................................. 6
2.6 Sensor ................................................................................................................. 6
2.7 Lens .................................................................................................................... 7
2.8 Electronical functions .......................................................................................... 7
3 Safety guidelines ...................................................................................................... 8
4 Illustration of the model key .................................................................................... 8
5 Commissioning ........................................................................................................ 9
5.1 Step 1: Installation ............................................................................................... 9
5.2 Step 2: Electrical connection ............................................................................. 10
5.2.1 Potential equalization ............................................................................................................... 11
5.2.2 Termination of the connection cable (pigtail) ........................................................................... 11
5.2.3 Power supply & protection ....................................................................................................... 13
5.2.4 Power supply & protection of the camera’s power circuit ........................................................ 13
5.2.4.1 Power supply & protection of the heating’s power circuit (optional) .............................................. 13
5.2.5 Video picture connection (CVBS) ............................................................................................ 14
5.2.6 Control interface (RS-422) ....................................................................................................... 14
5.2.7 Tests prior to switching on voltage .......................................................................................... 15
5.3 Step 3: Adjusting the picture ............................................................................. 15
5.3.1 Work preparation ..................................................................................................................... 18
5.3.2 Opening the pressure-resistant housing .................................................................................. 18
6 Maintenance / Servicing / Alterations ................................................................... 19
7 Repairs and Maintenance ...................................................................................... 19
8 Disposal / Recycling .............................................................................................. 19
9 Drawings ................................................................................................................. 20
10 Notes ....................................................................................................................... 21
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 3 of 24
Table of figures
Figure 1.1 Document overview .......................................................................................... 4
Figure 5.1 Potential equalization T03-VA… ..................................................................... 11
Figure 5.2 ExCam niteZoom – T03-VA-B-XXX-K-N ........................................................ 11
Figure 5.3 ExCam niteZoom – T03-VA-B-XXX-K-L ......................................................... 12
Figure 5.4 ExCam niteZoom – T03-VA-B-XXX-P-N ........................................................ 12
Figure 5.5 ExCam niteZoom – T03-VA-B-XXX-P-L ......................................................... 12
Figure 5.6 Setting the Baud-transmission rate................................................................. 15
Figure 5.7 FCB Control Panel of the ExCam niteZoom ................................................... 16
Figure 5.8 Control and visualization via a video server ................................................... 16
Figure 5.9 ExCam® niteZoom – lens and sensor board ................................................... 17
Figure 9.1 T03-VA-K1 ...................................................................................................... 20
Figure 9.2 T03-VA-K2 ...................................................................................................... 20
Revision history
Product: ExCam® niteZoom Title: User manual for the ExCam® niteZoom Doc. -Id. 131106-PT03BA-SS-ExCam niteZoom_en_rev.01
Author: Dipl.-Ing. S. Seibert
Date: November 06, 2013
Rev.-Index
Date
Name
Comments
Authorization of the ATEX Supervisor
00
Nov 06, 2013
S. Seibert
Compilation of the document
Tested and approved Nov 7, 2013 – S. Seibert
01
Aug 08, 2014
T. Gruber
Revision and correction
Tested and approved Aug 19, 2014 – S. Seibert
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 4 of 24
1 Document overview
Figure 1.1 Document overview
The present document is marked in red.
T03 ExCam Series:
(ATEX)
- EX Installation Manual
- EC Declaration of Conformity
- EC Type Examination
ExCam miniZoom:
- User Manual
- Datasheet
ExCam niteZoom:
- User Manual
- Datasheet
ExCam vario:
- User Manual
- Datasheet
ExCam IP:
- User Manual
- Datasheet
ExCam HD:
- User Manual
- Datasheet
T08 ExCam Series:
(ATEX/ IECEx, Bergbau)
- EX Installation Manual
- EC Declaration of Conformity
- EC Type Examination
ExCam miniZoom:
- User Manual
- Datasheet
ExCam niteZoom:
- User Manual
- Datasheet
ExCam vario:
- User Manual
- Datasheet
ExCam IP:
- User Manual
- Datasheet
ExCam IP1354:
- User Manual
- Datasheet
ExCam IP1355:
- User Manual
- Datasheet
ExCam IPQ1755:
- User Manual
- Datasheet
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 5 of 24
2 Technical Data
2.1 Parameters of the explosion protection
Identification marks according to Directive 94/9/EG: II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
Explosion protection (gas): Ex d IIC T6 Gb or Ex d IIB T6 Gb Explosion protection (dust): Ex t IIIC T80°C Db IP67
EC-type examination: TÜV 09 ATEX 7697 X Inspection record: 194/Ex.697.00/09 Allowed ambient temperature: -20° C … +50° C
2.2 Electrical parameters
Camera: Supply voltage: +12 VDC to +30VDC Reference power: +24 VDC Power input: 270 mA to 540 mA Maximum power input: 6.5 W (without heating)
Heating (optional): Supply voltage: +12 VDC to +24 VDC Reference power: +24 VDC Power input: ca. 1000 mA Maximum power input (-20°C): 10 Watt
2.3 System cable SKAxx
Outer diameter: 9.4 mm Max. bending radius: 150 mm Material outer sheath: PUR – flame retardant according to IEC 60322-1-2 Color outer sheath: RAL 9005 matt Video: 1 x 75 Ω Koax, 19 x 0.127 mm tinned AWG 24, plated copper braid, shielded RS 422: 2 x 2 x 0.25 mm2 (twisted pair) Cu shielded double wrapping foil Supply voltage camera: 2 x 0.75 mm2, polyolefine insulated Supply voltage heating: 2 x 0.75 mm2, polyolefine insulated
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 6 of 24
2.4 Mechanical parameters
Housing material: Stainless steel 1.4301 (AISI 304) and Stainless steel 1.4305 (AISI 303) Optional:
Stainless steel 1.4401 (AISI 316) or
Stainless steel 1.4404 (AISI 316L) Glass material: Borosilicate Protection level: IP 67 (IEC / EN 60529)
Weight T03-VA: With K1 flange: ca. 2,000 g With K2 flange: ca. 2,500 g
Dimensions T03-VA [WxHxD]: K1 flange, without pin and cable gland: 79 x 79 x 128 [mm] K1 flange, with pin and cable gland: 79 x 96 x 128 [mm] K2 flange, without pin and cable gland: 79 x 79 x 141 [mm] K2 flange, with pin and cable gland: 79 x 96 x 141 [mm]
Fitting of the flame proof gap Preventing the transmission of ignition (cylinder) T03-VA…: Nominal diameter: 57 mm ISO fit: H8 f7
2.5 Temperature range
T03-VA-X-XXX-X-N (without heating): 0° C to +50° C T03-VA-X-XXX-X-L (with heating): -20° C to +50° C
2.6 Sensor
Sensor: 1/3‘‘ Super HAD CCD II - technology Effective sensor resolution: PAL: 440,000 pixel (ca. 752 x 582) NTSC: 380,000 pixel (ca. 768 x 494) Horizontal resolution: PAL: 530 TV lines NTSC: 530 TV lines
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 7 of 24
2.7 Lens
AF-Zoom lens: 10 x optical / 4 x digital Focal distance (f): 5.1 mm to 51.0 mm Angle of view: 52° (wide) to 5.4° (tele) Aperture: F1,8 to F2,1 Minimal illumination: 0.0004 lux (1/4 s, 1/3 s mode & ICR on) Recommended illumination: 100 to 100.000 lux Minimal object distance: 150 mm (wide) 800 mm (tele)
2.8 Electronical functions
Electronical shutter function Serial control via VISCA/RS-422 Composite video (VBS) video output 1 Vpp Back Light Compensation (BLC) Auto White Balance (ATW) Aperture correction (APC) DSP SNR: 50 dB
Doc.-ID: 131106-PT03BA-SS-ExCam niteZoom_en_rev.01, page 8 of 24
3 Safety guidelines
Please observe the safety guidelines indicated in the ATEX installation manual of the ExCam series!
4 Illustration of the model key
The following model options are currently available for the ExCam ® niteZoom:
Product name
Model option
ATEX Type
housing option
(1)
Explosion group
(2)
Meter SKA02
(3)
Cable termin.
(4)
Housing heating
(5)
ExCam niteZoom
T03-
VA-
B-
005-
K- N
T03-
VA-
B-
005-
K- L
T03-
VA-
B-
005-
P-
N
T03-
VA-
B-
005-
P-
L
T03-
VA-
C-
005-
K- N
T03-
VA-
C-
005-
K- L
T03-
VA-
C-
005-
P- N
T03-
VA-
C-
005-
P-
L
(1) VA = Execution in stainless steel
(2) B = Explosion group IIB (standard - all gases except hydrogen, acetylene, carbon disulphide) C = E Explosion group IIC (all gases)
(3) Length of the connection line in meter (001 - 200) (5 meter is the standard length)
(4) K = Terminal block connection (standard) All signaling lines are spliced to single strands and furnished with wire-end ferrules to allow connecting the camera to a terminal block P = Plug- termination Approximately 30 cm of the system cable’s outer stealth is stripped. The power supply strands (RD, BK) are furnished with wire-end ferrules. The AWG24 cable is furnished with a BNC connector
(5) N = Normal Temperature (0° C – 50° C) L = Low Temperature (-20° C – 50° C)