Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 2 of 24
Content
1 Introduction .............................................................................................................. 4
2 Technical Data .......................................................................................................... 5
2.1 Parameters of the explosion protection ............................................................... 5
2.2 Electrical parameters of the camera .................................................................... 5
2.3 Electrical parameters of the heating (optional) .................................................... 6
2.4 System Cable SKDxx .......................................................................................... 6
2.5 Supply cable (optional) ........................................................................................ 6
2.6 Video technical data ............................................................................................ 7
2.7 Other technical data ............................................................................................ 7
3 Safety guidelines ...................................................................................................... 8
4 Illustration of the model key .................................................................................... 8
5 Commissioning ...................................................................................................... 10
5.1 Step 1: Installation ............................................................................................. 10
5.2 Step 2: Electrical connection ............................................................................. 10
5.2.1 Potential equalization ............................................................................................................... 11
5.2.2 Connection and protection ....................................................................................................... 12
5.2.3 Tests prior to switching on voltage .......................................................................................... 16
5.3 Optional steps ................................................................................................... 17
5.3.1 Work preparation ..................................................................................................................... 17
5.3.2 Opening the pressure-resistant housing .................................................................................. 18
6 Network access and visualization ........................................................................ 19
6.1 Browser Support ................................................................................................ 19
6.2 Assigning the IP address ................................................................................... 19
6.3 Password / Identification ................................................................................... 20
7 Maintenance / Servicing / Alterations ................................................................... 21
8 Repairs and Maintenance ...................................................................................... 21
9 Disposal / Recycling .............................................................................................. 21
10 Drawings & 3D models ....................................................................................... 22
11 Notes .................................................................................................................... 23
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 3 of 24
Table of Figures
Table 4.1 – Model key ....................................................................................................... 8
Figure 5.1 – ExCam IPP5635 potential equalization ....................................................... 11
Table 5.1 – Potential equilization ..................................................................................... 11
Figure 5.2 – ExCam IPP5635 T08-TNXCD-B-XXX-K-N .................................................. 12
Figure 5.3 – ExCam IPP5635 T08-TNXCD-B-XXX-P-N .................................................. 12
Figure 5.4 – ExCam IPP5635 T08-TNXCD-B-XXX-K-L(L) .............................................. 13
Figure 5.5 – ExCam IPP5635 T08-TNXCD-B-XXX-P-L(L) .............................................. 13
Table 5.2 – Pin assignment SKDxx and plug contact RJ45 ............................................. 15
Figure 5.6 – RJ45 Contact assignment ........................................................................... 15
Figure 5.7 – SKDxx Pin assignment ................................................................................ 15
Table 5.3 – Pin assignment supply cable ........................................................................ 16
Figure 6.1 – Axis IP Utility ................................................................................................ 20
Revision history
Product: T08 ExCam® IPP5635 Titel: User manual ExCam® IPP5635 Doc. -Id. 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx Author: Dipl.-Ing. Steffen Seibert Date: Jule 20th, 2016
Rev.- Index
Date
Name
Comment
Approved by EX Officer
0
2016/07/20
S. Seibert
Compilation of the document
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 4 of 24
1 Introduction
The ExCam IPP5635 is a high performance IP dome camera of the latest generation with a 2 megapixel resolution of 1920 x 1080p pixel. It is certified according to ATEX, IECEx, and EAC-Ex.
The dome camera has a continuous 360° pan and a 180° tilt function; the adjustment of the picture is done automatically. A special feature is the high speed and precession with which the pan as well as the tilt functions is carried out.
The ExCam Series is certified according the European ATEX directive as well as to the international IECEx directive. The ex-protective housing is suitable for the usage within the Ex zones 1, 2, 21, and 22 including the gas group IIB and the dust group IIIC. It is also certified according to EAC-Ex.
During the design of the ExCam IPP5635, the main focus was put on security as well as on mechanical precision and high-quality stainless steel. In addition, the modular design allows, for example, a connection via FOC.
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 5 of 24
2 Technical Data
2.1 Parameters of the explosion protection
Identification marks according to
directive 2014/34/EU: II 2G (Zone 1 and 2) II 2D (Zone 21 and 22)
Explosion protection (gas): Ex d IIB T6 Gb or Ex d IIB T5 Gb
Explosion protection (dust): Ex tb IIIC T80°C Db IP68 or Ex tb IIIC T95°C Db IP68 or
Protection level: IP 66/68 (IEC /EN 60529)
Transportation and storage temperature (EX): -40°C…+60°C Ambient temperature (EX)1: -50°C…+50°C (T6)
Noticed body: TÜV Rheinland (number 0035) EU Type Examination: TÜV 14 ATEX 7539 X IECEx TUR 14.0026X
Test protocol ATEX: 557/Ex.539.00/14 Test report IECEx: DE/TUR/ExTR14.0026/00 Quality Assessment Report: DE/BVS/QAR14.0006/00
2.2 Electrical parameters of the camera
Axis P5635-E Power supply: PoE, IEEE 802.3at Class 4 Reference power: 48 V DC (44...54 V DC) Maximum power input: 20 W
1
Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range.
For maximum functional temperature range (MTBF) see chapter 2.12
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 6 of 24
2.3 Electrical parameters of the heating (optional)
Power supply: 12…30 V DC Reference power: 24 V DC Maximum power input: 40W @-30°C 60W @-50°C Suggested fuse supply cable: 6000mA – T at 3G 1.5 mm2
2.4 System Cable SKDxx
Description: Data transfer and power supply of the camera
module (DIN EN 60079-14 conform) Color of sheath: Green (GN), similar RAL6018 Outer diameter: 9.1 mm ± 0.2 mm Bending radius: 100 mm Cable: 4 x 2 x AWG22/1 CAT.6a Characteristics: PUR halogen free, flame retardant, UV resistant, chemical resistance, shielded Interface: P version: RJ-45 (EIA/TIA-568B) 10BASE-T/100BASE-TX PoE K version: 8x single pin twisted pair (solid conductor 0.64 mm2, about 5 mm stripped) 1x shield (Cu braid 2.5 mm2, ferules) 10BASE-T/ 100BASE-TX PoE
2.5 Supply cable (optional)
Description: Power supply of the heating elements including temperature controller, Ölflex® 440p2 (DIN EN 60079-14 conform) Color of sheath: Black (BK) matt, similar RAL9005
2
Further cables available upon request, e.g. „Ölflex® Petro FD 865 CP“ (high resistance against oil and drilling liquids) or „XPLE
Armoured 3 x 2.5“ (extremely robust, particularly designed for offshore environments)
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 7 of 24
2.6 Video technical data
For details regarding video technical data of the installed AXIS P5635-E dome camera, please refer to the AXIS® product documentation:
http://www.axis.com/us/en/products/axis-P5635-E
2.7 Other technical data
Permitted ambient temperature (MTBF)3: 0 °C +50 °C (type N)
-30 °C … +50 °C (type L)
-50 °C … +50 °C (type LL)
Protection level EN 60529/IEC 529: IP 68 Test conditions: 24 h/ 3 m water column at
5° C. An additional mechanical protection
against water jets is recommended Housing material: Stainless steel MNo.: 1.4404 (X2CrNiMo17-12-2), AISI 316L (V4A) Material sight glass: LEXAN Weight: 15 kg Dimensions housing (WxHxD): D195 mm x 378 mm
3
Functional temperature range concerning the operational temperature range of the installed components according to manufacture
declarations (MTBF – meantime ration duration between failures). For ambient temperature ranges relevant for explosion protection (ATEX, IECEx) see chapter 2.1 – Explosion protection)
Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 8 of 24
3 Safety guidelines
Please observe the safety guidelines indicated in the EX installation manual of the T08 ExCam series!
4 Illustration of the model key
The following model options are currently available for the ExCam IPP5635:
Model options
Ex product name1)
Type2)
Housing combination3)
Gas expl. group4
Cable length/m SKDxx/SKLxx
5)
cable termin.6)
Temperature range7)
ExCam IPP5635
T08-
TNXCD
B-
005-
K- N
T08-
TNXCD-
B-
005-
P-
N
ExCam IPP5635
T08-
TNXCD-
B-
005-
K- L
T08-
TNXCD-
B-
005-
P-
L
ExCam IPP5635
T08-
TNXCD-
B-
005-
K-
LL T08-
TNXCD-
B-
005-
P-
LL
Table 4.1 – Model key
1) ExCam IPP5635 = Functional camera description of the ExCam IPP5635 network camera
(Basis: AXIS P5635-E MK2)
2) T08 = Certified production type, device designation „T08 ExCam series“, EU type
examination: „TÜV 14 ATEX 7539 X“ and „IECEx TUR 14.0026X“
3) TNXCD = Ex-d housing
4) B = Explosion group IIB/ IIIB (Standard - all gases except hydrogen, acetylene, carbon disulfide, flammable fibrous materials, and non-conductive dusts)
5) 005 = Length of the connection line in meter at delivery. The standard cable length is 5 m (minimum/maximum cable length: 001100 [m])