Salutron HRM8700 User Manual

FCC ID:N7P-HRM8700
FCC ID:N7P-HRM8700FCC ID:N7P-HRM8700FCC ID:N7P-HRM8700FCC ID:N7P-HRM8700
HRM8700
Combo Heart Rate Module
User Guide

y
Revision History:
CONFIDENTIAL
Revision
0.1 07/23/17 Preliminary Draft BC
Release
date
Description B








Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 2 of 21
CONFIDENTIAL
Contents
General Description .............................................................................................................................. 4
Features: ............................................................................................................................................. 4
Physical Dimensions: Inches (mm) ......................................................................................................... 5
Connection Diagram: (Typical) .............................................................................................................. 6
Electrical Characteristics: ...................................................................................................................... 7
ECG Measurement: ............................................................................................................................... 7
5KHZ Wireless Specification: ................................................................................................................. 7
BLE/ANT+ Specification: ....................................................................................................................... 7
1. UART COMMUNICATION PROTOCOL: ................................................................................................. 9
1.2.Block Diagram .......................................................................................................................................... 9
2. OPERATION ..................................................................................................................................... 9
2.1. Description............................................................................................................................................... 9
2.2. UART Specification .................................................................................................................................. 9
2.3. Equipment Assomptions ........................................................................................................................ 10
2.4. HRM8700 default configuration ............................................................................................................. 10
2.5. Equipment and HRM8700 Operations ................................................................................................... 11
2.6. HRM8700 OTA. ...................................................................................................................................... 12
3. UART COMMUNICATION PROTOCOL PACKETS ................................................................................... 13
3.1. Packets .................................................................................................................................................. 13
3.2. Example of Sending Packets Equipment Console .................................................................................. 13
3.3. Example of Sending Packet to HRM8700 .............................................................................................. 14
Appendix A : Grounding and ESD Recommendations .............................................................................. 15
Appendix B: HRM8700 Placement Guideline ........................................................................................... 18
FCC/IC statement ................................................................................................................................ 20
FCC statement .............................................................................................................................................. 20
IC statement ................................................................................................................................................. 20
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 3 of 21
Model HRM8700
Wireless Heart Rate Monitor Specifications
General Description
The Model HRM8700 is a wireless receiver and
Handgrip Heart Rate Monitor Combo. It is designed to manage and support ECG contact heart rate and the reception of wireless heart rate data from BLE, ANT+, standard 5kHz chest straps or wearable heart rate transmitters or devices.
Once enabled by the Console, the HRM8700
actively scans for local HR transmitter signals, and supports a user selection/pairing protocol processed by the Console.
Once a HR transmitter is selected/paired, the
HRM8700 streams the user heart rate data until the end of the workout session, then ‘unpairs’.
The HRM8700 contact heart rate monitor can
quickly and accurately measure the heart rate from an ECG signal under noisy environments.
The HRM8700 simultaneously processes
Handgrip Heart Rate and Wireless Heart Rate data. Either can be specified as the priority heart rate.
Features:
Direct connection to equipment; no phone
device or app ‘middleman’
Support ECG contact heart rate Supports multiple inbound sources for HR:
BLE, ANT+, 5kHz
Automatic proximity sensing to minimizing
interference from competing wireless HR signals
Console controllable proximity commands
allowing ‘customization’ of the scanning proximity during integration development of the HRM8700 into the console
Simplified user pairing routine Future-proof: OTA updateable to support
future features (based on console pass­through, if available)
Interface: UART, custom command protocol
The HRM8700 series combo heart rate module delivers high performance ECG contact and telemetry heart rate monitoring - for both commercial/club and home cardio equipment applications.
CONFIDENTIAL
The HRM8700 communicates and passes the heart rate data from the heart rate monitor to the equipment console through proprietary UART protocol.
The HRM8700 series offers a special proximity pairing feature that allows the equipment console to discover only the HR transmitting devices in close proximity. This feature minimizes unwanted devices and speeds up the pairing process, especially useful in health club environments where there may be multiple BLE or ANT+ devices present. After successful pairing, the reception distance will automatically increase to maximum range.
The HRM8700 receiver also supports legacy S­pulse contact heart rate and 5kHz chest strap data reception. It utilizes Salutron’s proprietary Digital Crosstalk Control and Digital Noise Filter algorithms that can filter out unwanted competing chest strap signals. This supports better wireless reception and reduce 5kHz noise from potentially unfriendly high ‘noise’ environments coming from power systems and console electronics.
o ECG handgrip contact heart rate with R-R
interval output (Optional)
o BLE smart and ANT+ data reception o Standard 5.3kHz chest strap, coded and un-
coded signal reception
o Proximity pairing feature. o UART communication protocol o Stationary Bike FE-C support o 3~6V operation. o RoHS compliant.
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 4 of 21
CONFIDENTIAL
Physical Dimensions: Inches (mm)
Figure1:Physicaldimensions
The physical properties of the HRM8700 allow for easy integration in your existing equipment. See above picture for the physical dimensions of the board. Preferred headers may be specified, with Salutron’s consultation. Because of its small size and weight, the board can be fastened using adhesive tape, or #2 screws.
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 5 of 21
Connection Diagram: (Typical)
CONFIDENTIAL
Figure 2: Connection Diagram
TYPE PIN No. DESCRIPTION
HD1 – Ground Strap 1 Earth Ground
1 RA, right primary sensor
HD2 – Right Sensor
HD3 – Left Sensor
J1 – Main
2 LL, common sensor 3 Shield 1 LA, left primary sensor 2 LL, common sensor 3 Shield 1 GND 2 +5V 3 TXD 4 RXD
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 6 of 21
Electrical Characteristics:
Symbol Parameter Conditions Min. Typ. Max. Units
VS Supply voltage - 3 5 6 V
IS Supply current Vcc = 5V 5.2 7.5 10.5 mA
To Operating Temperature
CONFIDENTIAL
-
-10
-
60
°C
Ts
Storage Temperature
-
-40
-
85
°C
ECG Measurement:
Symbol Parameter Conditions Min. Typ. Max. Units
HR Heart EC Simulator 30 - 240 BPM
CHR sensor ECG sensitivity 0.1 - - mV
Ta Acquisition Time Bike/treadmill 3 5 10* seconds
*Among the contributing factors resulting in long HR acquisition are motion induced physiological artifact, electrical disturbance from control electronics, transient motor drive loading, and skin contamination via hand cream, cosmetics, and dust,
5KHZ Wireless Specification:
Parameter Conditions Min. Typ. Max. Units
5KHZ Wireless reception range Noise free environment
5KHZ Wireless reception frequency
T= 25ºC, Vcc =5.0V
31 80
4.8 5.3 5.9 KHz
35 90
39 100
Inches cm
Heart rate detection Output format UART Protocol
T= 25ºC, Vcc =5.0V
30 - 240 BPM
BLE/ANT+ Specification:
Minimum Typical Maximum Unit HR Measurement
Range 30 - 240 beats per minute Frequency 2402 - 2480 MHz Center Frequency - 2440 - MHZ Channel Bandwidth - - 2 MHZ
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 7 of 21
CONFIDENTIAL
Low speed Crystal Freq - 32.768 - KHZ
Feet
Meter
High speed Crystal Freq - 32 - MHZ Channel Spacing - 2 - MHZ No. of channels used - - 40 Channels Modulation GFSK Output power -20 - 4 dBm Open Air range - - 10 Meter Power Consumption Standby mode - 5 - mA Operation Modes
Device Searching Mode - 10 10.5 mA Heart rate Data transfer - 5 5.5 mA
2.4GHZ Transmission distance (line of sight)*
65 20
Vdd=5.0V @ 25°C
-
-
-
-
*Note:thenatureofphysicalobstructionsand/or2.4GHzradiointerferenceinthesurroundingarea couldaffectthereceptionandtransmissionrange.
Copyright 2017, Salutron, Inc. Revision 0.1 Revision Date: 07/23//17 Page: 8 of 21