Salus Controls SP120 Instruction Manual

S-Series Single Channel Controller
2
S-Series Single Channel Controller
Model No SP120
Instruction Manual
PRODUCT COMPLIANCE
This product complies with the essential requirements of the following EC Directives:
Electro-Magnetic Compatibility Directive 2004/108/EC
Low Voltage Directive 2006/95/EEC
EC Marking directive 93/68/EEC
SAFETY INFORMATION
These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model.
These instructions are intended to apply in the United Kingdom only, and should be followed along with any other statutory obligations - if you are in any doubt, please contact the Salus Controls technical helpline.
This accessory must be fitted by a Competent person, and installation must comply with the guidance provided in the current editions of BS7671 (IEE Wiring Regulations) and Part ‘P’ of the Building Regulations. Failure to comply with the requirements of these publications could lead to prosecution.
Always isolate the AC Mains supply before opening or removing the unit from the wall or wall box.
Please leave these instructions with the end user where they should be kept in a safe place for future reference.
SP120 INSTRUCTION MANUAL2
INTRODUCTION
A heating controller is used to switch the heating system in your home on and off as needed. It works by controlling the heating boiler according to a series of programmed settings that take effect at different times of the day.
The SP120 from Salus Controls is a stylish and accurate single channel programmable heating controller. Fitted with a large, easy to read Liquid Crystal Display (LCD), this controller has been specifically designed to be used for volt free and 230V AC heating applications.
The use of the revolutionary Touch Ring technology makes for simple usage, and is coupled with a unique, smart design and the ‘one touch’ operation makes the SP120 easy to operate.
FEATURES
Touch Ring Technology
Large LCD with white backlight
Stylish Casing
Radio Controlled Clock (RCC)
Volt Free Contacts
Manual Time and date Setting Option
Advance +1Hr function (maximum 9 hours)
Holiday Function
Service Function
Three On/Off Periods each day
Built in Start-up Programmes
3SP120 INSTRUCTION MANUAL
INSTALLATION
Please read the important safety information at the start of this manual before you begin to install the device. The ideal position to locate the SP120 programmable heating controller is about 1.5m above floor level. It should be mounted in a location where the controller is easily accessible, reasonably lit and free from extremes of temperature and draughts. Do not mount the controller on an outside wall, above a radiator or in a location where it may be subjected to direct sunlight.
The SP120 should be mounted in a location where it will not come into contact with moisture or condensation, as this can affect the Touch Ring operation.
To ensure trouble free reception for both the Radio Controlled Clock (RCC) and the Radio Frequency (RF) signal, always ensure that the programmable controller is mounted away from any possible sources of interference (such as radios, TV sets, computers, etc.), and is not mounted on or in close proximity to large metal objects. Installing the SP120 in enclosed areas such as cellars and basements is not recommended.
The electrical connections to the SP120 are made to the terminal strip within the controller itself. Connection details are shown below - no Earth connection is required for the correct and safe operation of the SP120.
Volt Free Connections
Terminal Description Terminals
4 (COM) Volt Free Common
3 (NO) Normally Open
2 (NC) Normally Closed
1 No connection
L Mains Live
N Mains Neutral
230V AC Connections
Terminal Description Terminals
4 Linked to Live
3 (SL on) Switched Live On
2 (SL off) Switched Live Off
1 Live
L Mains Live
N Mains Neutral
SP120 INSTRUCTION MANUAL4
After installing the controller in a suitable location, wiring connections can be made as shown above.
The following criteria apply to the installation:
• The incoming AC mains supply should be 230V AC and fused at 6 Amps.
• Optimum cable size for installation is 1.5 mm
2
; wiring colours should be in accordance
with the current requirements of the IEE Wiring Regulations.
• Cable entry should be made at the cable entry point
• All wiring connections should be securely made, and be firmly gripped beneath the terminal clamp.
Do not restore the mains supply to the system until all associated items are fully installed.
NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this controller consult either with a qualified Electrician, Heating Engineer or your boiler / heating system supplier for advice on how to continue.
Do not remove or refit the SP120 without the mains supply to the system being isolated.
AFTER INSTALLATION
After completing installation and powering up the SP120 for the first time the controller will behave in the following way:
All the indicators on the display and the backlight will be turned on for a few seconds. The internal firmware version will then be displayed for a few seconds, and the SP120 will then operate in Normal mode (controller output OFF).
If the Reset Button is pressed, the SP120 will behave in the same way as described above, and any previously saved user settings will be deleted and overwritten with the default settings, except when the SP120 is in SERVICE mode.
5SP120 INSTRUCTION MANUAL
USER INTERFACE AND CONTROLS
The status and operation of the SP120 can be clearly seen on the large backlit Liquid Crystal Display (LCD) - this display allows the user to see at a glance the current status of the heating system.
The display consists of a combination of symbols and alphanumeric displays. The top row displays status indicators, the centre row is a time and day of the week indicator and the bottom row is an alphanumeric display for menu and status messages.
The status indicator symbols and their meanings are shown in the following table:
Indicator Description Function
Clock Display Displays the day and time
Alphanumeric Display Displays menu and other status messages
ON Mode indicator Indicates Continuously On
ONCE Mode indicator Indicates output is turned on for one period per
day, from PROGRAM 1 ON to PROGRAM 3 OFF
AUTO Program Mode indicator Indicates Auto ON or Auto OFF
programme is running
OFF Mode indicator Indicates Continuously Off
RCC indicator Indicates the status of the Radio Controlled Clock
Holiday indicator Indicates Holiday operation mode is selected
Touch Lock indicator Indicates Touch Lock is activated
Service indicator Indicates Service function is active
SP120 INSTRUCTION MANUAL6
There are few user controls for the SP120, making the controller very easy to operate. The controls are a Touch Ring (which surrounds the user display), two touch sensitive buttons, a reset button and a slide operated switch mounted on the side of the controller.
These controls are shown here, along with a description of each of their functions.
USER CONTROL FUNCTION SUMMARY:
Key / Operation Functions
Touch Ring (move clockwise) Increases the selected setting and scrolls
Touch Ring (move anti- clockwise) Decreases the selected setting and scrolls
OK Key Enters Menu or confirms a menu selection
Arrow (Back) Key Single press goes back to the previous screen
Reset Button Resets the controller to default (original factory)
Slide Switch Activates and deactivates the key lock function
down the menu selection
up the menu selection
or previous option selected. Press and hold for 2 seconds to return to NORMAL mode
settings, except when in SERVICE mode.
(prevents accidental changes)
7SP120 INSTRUCTION MANUAL
OPERATION
The SP120 is configured and adjusted by the use of an innovative and stylish Touch Ring, and two touch sensitive buttons. The Touch Ring surrounds the controller display, and is operated very easily by moving your finger around the ring.
ACCESSING THE MENUS
The Arrow key is not active when the SP120 is in NORMAL mode. To access the Menu screens, press the OK key twice and backlight is now ON. The first menu displayed is the BOOST menu. Use the Touch Ring to scroll through the Menus, and press the OK key to select the menu you want to use:
You can scroll through the menus in either direction (forwards or backwards) depending on the direction you move your finger around the Touch Ring. The menus are displayed in the order shown in the picture above.
Pressing the Arrow key will return the SP120 to NORMAL mode. The controller will also return to NORMAL mode after 10 seconds if no Key is pressed or if no movement is detected on the Touch Ring.
SP120 INSTRUCTION MANUAL8
Loading...
+ 18 hidden pages