Digital Thermostat
Models: VS30W and VS30B
INSTALLER / USER MANUAL
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

02 VS30W and VS30B Installer Manual
Contents
VS30
1 x Installer / User manual
4x AAA Batteries
Digital Thermostat
Models: VS30W and VS30B
INSTALLER / USER MANUAL
Fixing screws
Contents
Box Contents
Introduction
Product Compliance
Installation
User Guide
Parameter Settings
Installers Notes
Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation
guide please go to
www.salus-controls.com
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing the room thermostat
VS30. The VS30 is a 230V digital thermostat
which oers simple temperature control of your
heating system.
By purchasing the VS30 you have decided on a
digital room thermostat which allows you to
adjust surface heating appliances individually,
such as underoor, wall or panel heating.
A clear energy saving is possible by reducing
temp.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magnetic
Compatibility Directive 2004/108/EC
Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations.
The VS30 is to be used for room
control of hot water heating systems
inside the house.
Installation
This product must be tted by a competent
person, and installation must comply with the
guidance, standards and regulations applicable
to the city, country or state where the product
is installed. Failure to comply with the
requirements of the relevant guidance,
standards and regulations could lead to injury,
death or prosecution.
Always isolate the AC mains supply
before installing or working on any components
that require 230V AC 50Hz supply.
We hope you enjoy this product...
VS30W and VS30B Installer Manual 03
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains
supply before removing the cover.
230V AC
Emergency
Switch o the voltage to the indivdual thermostat
wring centre or complete system.
Installer parameter settings
The VS30 is equipped
with installer parameter section.
This must only be entered
by the installer or competent
person. Changing these parameters
can have a serious eect on
your heating system. See page 41.
For the installer
Please enter any parameter
changes in the installer notes section.
04 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Installation – Terminal Connections
Understanding your terminal connections
Rear of VS30
Power Terminals 230 Vac
Used for supplying power to the
unit and switched output.
NSB (Night Set Back) Connection
Used for a 230V output to other
thermostat. See page 8.
Sensor Terminals (Optional)
Can be used for external AIR
or Floor sensor.
1
3
3 2 1
2
VS30W and VS30B Installer Manual 05
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Installation – Thermostat Mounting
1
3
2
60mm
Wall Mounting
For wall mounting, mark and
mount the rear case to the wall.
The VS30 is suitable for wall boxes
with a centre hole distance of : 60mm
Gently remove front housing.
06 VS30W and VS30B Installer Manual
Gently remove front housing.
Only for ush
mounting boxes
with horizontal
xing holes.
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the VS30 room thermostat is best positioned
in a draft free area, and at 130cm from the oor. Do not position the thermostat near any heat
source, behind curtains, direct sunlight or an area of high humidity.
VS30W and VS30B Installer Manual 07
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

08 VS30W and VS30B Installer Manual
S2
S1
NSB
SL
L
N
S2
S1
NSB
SL
L
N
Sensor Terminal (optional)
Sensor Terminal (optional)
Night set back output
Load (Thermal Actuators)
Live 230V AC 50Hz
Neutral
L N
Wiring Centre
Thermal
Actuator
Optional SALUS
Sensor
Installation – Terminal Connections
L N
NSB for other
thermostats
Output
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Installation – Terminal Connections
Power Terminals
NSB (Night Set Back) Connection
Sensor Terminals (if applicable)
You are ready to secure the rear housing to the wall box
Check that the wiring is completed for:
1
2
3
Please use the screws provided
Ensure the orientation arrow
is pointing upwards.
VS30W and VS30B Installer Manual 09
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:38

Installation – Thermostat Mounting
1
Fit the front housing to the rear housing
Align the front housing
at the top edge.
2
Lightly press until you
hear a positive click.
Ensure the pin connections are aligned
10 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39

Installation – LCD Graphics
1
2 3 4 5 6 7
8
9
11
12
14
13
10
16
15
VS30W and VS30B Installer Manual 11
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39

ICON FUNCTION
BOX means to select the mode
e.g. means the current setpoint is Hi temp, means the Hi temp is not selected.
Sunny: Hi comfortable temperature.
Cloudy: Middle comfortable temperature.
Moon: Low comfortable temperature.
Programmable thermostat Program mode indicator: Indicates program is running,
Auto On or Auto O. For group thermostat this indicates that it is a member of a group.
Party indicator:
When Party mode is active.
Vacation indicator:
When Vacation mode is active.
Frost protection indicator:
Frost protection is active, not available in cooling mode (if applicable).
Installation – LCD Graphics
1
2
3
4
5
6
7
12 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39

Installation – LCD Graphics
ICON FUNCTION
Heat indicator:
Indicates heat is required.
Cool mode indicator:
Indicates cooling is required (if applicable).
Temperature indicator:
Display the room temperature.
Display the set-temp.
Also used to show the other information.
Temporary manual override indicator:
If the set temperature is changed when in program mode,
the hand will appear until the next program start time.
Programs number indicator:
In AUTO program mode or Temporary override is running,
it means the current program running.
Day indication:
1 = Monday.
8
9
10
11
12
13
VS30W and VS30B Installer Manual 13
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39

Installation – User Interface
ICON FUNCTION
Floor sensor probe indicator:
Show only when Air + Floor sensor is connected.
Setting indicator:
Indicates the unit is in setting mode when program setting.
Indicate’s the manual mode.
Keylock indicator:
Shows that keys are inactive.
14
15
16
14 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39

Installation – User Interface
KEY FUNCTION
1. Increase or decrease setpoint temperature.
2. Increase or decrease Day, Clock, Timer, Party and Holiday.
3. Select installer parameter value.
1. Mode selection.
2. Long press to return to home display without saving.
3. Short press to return to the previous screen when it is in user/installer setting mode.
1. OK key: Short press to conrm selection.
2. Long press to save and exit.
3. Long press to enter the user settings.
Lock/Unlock.
Enter Installer parameter settings.
Test mode.
OR
+
++
5 SECONDS
5 SECONDS
5 SECONDS
+
OR
VS30W and VS30B Installer Manual 15
INSTALLATION
iT600 VS30W - VS30B Installer - User Manual 014_Layout 1 16/07/2014 14:39