Salus VS20WRF, VS20BRF, VS10WRF, VS10BRF User Manual

Page 1
4 in 1 Digital Thermostat RF
Models:VS20WRF and VS20BRF
VS10WRF and VS10BRF
INSTALLER / USER MANUAL
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 2
Contents
1 x Installer / User manual VS10WRF
4x AAA Batteries
VS20BRFFixing screws
Contents
Box contents Introduction Product Compliance System options overview Installation Parameter Settings Error Codes User Guide Installers notes Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation guide please go to www.salus-controls.com
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 3
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing the SALUS 4 in 1 room thermostat it must be used with the CO10RF Zigbee Coordinator. The Zigbee coordinator allows communication with other devices in the iT600 RF system range. Other Zigbee devices include wiring centre, system receiver & TRV.
iT600RF Range
Product Compliance
This product is CE compliant and meets the following EC Directives Electro-Magnetic Compatibility directive 2004/108/EC Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations The SALUS VS10/20RF is to be used for room control of heating and hot water systems inside the house.
SALUS Wiring Centre KL10RF
RX10RF
TRV10RF
We hope you enjoy this product...
VS20WRF and VS20BRF Installer Manual 03
VS20 Thermostat
CO10RF
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 4
Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains supply before removing the cover.
Emergency
Switch o the voltage to the individual thermostat wring centre or complete system.
Installer parameter settings
The SALUS VS10 and VS20 are equipped with installer parameter section (see page 57) this must only be entered by the installer or competent person. Changing these parameters can have a serious eect on your heating system
For the installer
Please enter any parameter changes in the installer notes section (pages 90)
230V AC
These instructions are applicable to the SALUS model stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 5
VS20WRF and VS20BRF Installer Manual 05
System Overview - Conguration Options
Programmable Room
Thermostat (PRT)
The unit can be congured to either one of the following
* Grouping and timer option only available
when used with wiring centre.
1
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
TRV
Towel Rails
Group Control
Thermostat*
2
Group
Thermostat*
3
Timer
4
SYSTEM
OVERVIEW
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 6
System Overview - Conguration Options
Programmable Room Thermostat (PRT)
When congured for PRT (see page 32) it mainly works by itself and allows the user to have separate Time and Temperature control of each zone on the wiring centre, radiator valve or system receiver. Features like Vacation , Party frost mode have to set on each individual thermostat. All PRTs paired with a wiring centre can also use the global heat/cool changeover function if the your system supports this. This is achieved by using the heat/cool changeover connection on the wiring centre (see note 8 on wiring centre guide).
Group Control Thermostat
When congured for a PRT (see page 32) it can operate as a group control thermostat by assigning a group when pairing with the wiring centre this allows central control of up to 7 group thermostats see below, there can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature override, Holiday, Party, Frost modes, can be selected centrally from the Group Control Thermostat. Holiday will also be applied to a timer if applicable. The group thermostats can be also globally changed from heating to cooling thermostats if you system supports this by using the switched input connection on the WC (see note 8 on the wiring centre guide).
Group Thermostat
When congured as a digital thermostat and assigning a group when pairing with a WC it can operate as a group thermostat (see page 31), in group mode the group thermostat will follow the time schedule and any override modes of the group control thermostat. At least one group control thermostat is required for grouping see above. The group thermostat can have its own programmed temperatures, manual override and also be removed from the group temporarily or permanently.
Timer
When congured to timer (see page 32) the unit will operate as a timer with no temp control. This can be used for hot water control. The timer will also follow Holiday mode from the group control thermostat if applicable.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:35 Stron
Page 7
System Overview - Zigbee Coordinator
VS20WRF and VS20BRF Installer Manual 07
Zigbee coordinator required for communication between these devices.
KL10RF
VS10 / VS20RF
TRV10RF
RX10RF
CO10RF
SYSTEM
OVERVIEW
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 8
System Overview - iT600 System
The thermostat can communicate with all these iT600 devices
System Receiver congured to boiler receiver. Refer to system receiver manual RX10RF.
System Receiver congured to one room receiver RX2. Refer to system receiver RX10RF.
Max 3 TRV per thermostat
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 9
System Overview - Hot Water Option
When the unit is congured as a hot water timer (see page 32) there are two methods of connecting the cylinder thermostat.
Unit congured to Hot Water Timer.
Cylinder thermostat options
1 Connected direct to WC (Default)
2 Connected direct to VS10/20RF (requires additional parameter change. See page 57)
VS20WRF and VS20BRF Installer Manual 09
SYSTEM
OVERVIEW
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 10
System Overview - Hot Water Option
1 Connected direct to WC (Default)
For convenience there is a unique built in option allowing the cylinder thermostat to be connected to either the HW Timer or Wiring Centre.
Please refer to note 1 on Wiring Centre guide and pages 15 and 20 for more information.
2 Connected direct to VS10RF/20RF
(requires additional parameter change see page 37)
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 11
VS20WRF and VS20BRF Installer Manual 11
Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the unit is best positioned in a draft free area and at 130cm from the oor. Do not position the thermostat near any heat source, behind curtains, direct sunlight or an area of high humidity.
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 12
Carefully remove the front housing.
Installation – Thermostat Mounting VS20WRF
1 3
2
60mm
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 13
Installation – Terminal Connections VS20WRF
Understanding your terminal connections
Rear of unit
Sensor Terminals
Can be used for external AIR, Floor sensor when congured as thermostat. Can also be used for Cylinder thermostat when congured for HW. See page 57.
1
1
VS20WRF and VS20BRF Installer Manual 13
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 14
Installation – Thermostat External Sensor VS20WRF
Note: If you are using an external sensor, the unit has to be congured for External Air Sensor or Floor Protection Sensor please see device parameter setting page 57.
SALUS External sensor (Sold separately)
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 15
Installation – Hot Water Timer Cylinder Thermostat VS20WRF
Note: The unit can be congured for Cylinder thermostat or connected to the Hot Water Timer. Please see device parameters page 57. For additional Wiring Centre information refer to note 1 on Wiring Centre guide.
HW Timer connected cylinder thermostat
IN OUT
Link must be tted
WC connected cylinder thermostat (Default)
Cylinder
thermostat
SALUS CT100
IN OUT
VS20WRF and VS20BRF Installer Manual 15
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 16
Installation – Thermostat Mounting VS20WRF
1 2
3
4
Once you have connected your choice of external sensor (if applicable)
Insert batteries
Note: Please proceed to page 23
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 17
Carefully remove the front housing.
Installation – Thermostat Mounting VS10WRF
1 3
2
60mm
VS20WRF and VS20BRF Installer Manual 17
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 18
Installation – Terminal Connections VS10WRF
Understanding your terminal connections
Rear of unit
Power Terminals 230 Vac
Used for supplying power to the unit. 230V supply can be sourced from the wiring centre or any convenient source.
Sensor Terminals
Can be used for external AIR, Floor sensor when congured as thermostat. Can also be used for Cylinder thermostat when congured for HW.
1
2
12
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 19
Installation – Thermostat External Sensor VS10WRF
Note: If you are using an external sensor, the unit has to be congured for External Air Sensor or Floor Protection Sensor please see device parameter setting page 57.
VS20WRF and VS20BRF Installer Manual 19
SALUS External sensor (Sold separately)
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 20
Installation – Hot Water Timer Cylinder Thermostat
VS10WRF
Note: The unit can be congured for Cylinder thermostat or connected to the Hot Water Timer. Please see device parameters page 57. For additional Wiring Centre information refer to note 1 on Wiring Centre guide.
HW Timer connected cylinder thermostat
IN OUT
Link must be tted
WC connected cylinder thermostat (Default)
Cylinder
thermostat
SALUS CT100
IN OUT
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 21
Installation – Thermostat Mounting VS10RF
Check that the wiring is completed for:
1
2
Please use the screws provided
Ensure the orientation arrow is pointing upwards.
Power Terminals
Sensor Terminals (if applicable)
You are ready to secure the rear housing to the wall box
VS20WRF and VS20BRF Installer Manual 21
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 22
Installation – Thermostat Mounting
1
Fit the front housing to the rear housing
Align the front housing at the bottom edge.
2
Lightly press until you hear a positive click.
Ensure the pin connections are aligned
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 23
Installation – LCD Graphics
ICON FUNCTION
BOX means to select the mode e.g. means the current setpoint is Hi temp, means the Hi temp is not selected.
Sunny: Hi comfortable temperature.
Cloudy: Middle comfortable temperature.
Moon: Low comfortable temperature.
Programmable thermostat Program mode indicator: Indicates program is
running, Auto On or Auto O. For group thermostat this indicates that it is a member of a group.
Party indicator:
When Party mode is active.
Vacation indicator:
When Vacation mode is active
Frost protection indicator:
Frost protection is active, not available in cooling mode (if applicable)
RF Transmission is active
Group 1 Control Thermostat
Group 2 Control Thermostat
Group 1 Thermostat
Group 2 Thermostat
VS20WRF and VS20BRF Installer Manual 23
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 24
Installation – LCD Graphics
ICON FUNCTION
Heat indicator:
Indicates heat is required.
Cool mode indicator:
Indicates cooling is required (if applicable)
Temperature indicator:
Display the room temperature. Display the set-temp. Also used to show the other information.
Temporary manual override indicator:
If the set temperature is changed when in program mode, the hand will appear until the next program start time.
Programs number indicator:
In AUTO program mode or Temporary override is running, it means the current program running.
Day indication:
1 = Monday
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 25
Installation – LCD Graphics
ICON FUNCTION
Hot Water (HW) indicator:
Unit has been congured for HW Timer.
Hot Water (HW) indicator:
Indicates that there is Hot Water demand.
HW Program mode indicator:
Indicates program is running.
HW Mode indicator:
Mode for 1 period of HW a day, from Program 1 ON to Program 3 OFF.
HW Mode indicator:
Indicates continuously On.
HW Mode indicator:
Indicates continuously O.
HW Mode indicator:
Indicates Boost +1hr override.
VS20WRF and VS20BRF Installer Manual 25
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 26
Installation – LCD Graphics
ICON FUNCTION
Floor sensor probe indicator
Show only when Air + Floor sensor is connected.
Low battery indicator:
Batteries need to be replaced.
Setting indicator:
Indicate the unit is in setting mode when program setting. Indicate the manual mode.
Keylock indicator:
Shows that keys are inactive.
26 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 27
Installation – User Interface
KEY FUNCTION
1. Increase or decrease setpoint temperature.
2. Increase or decrease Day, Clock, Timer, Party, Holiday and Boost.
3. Select installer parameter value.
1. Mode selection.
2. Long press to return to home display without saving.
3. Short press to return to the previous screen when it is in user/installer setting mode.
1. OK key: Short press to conrm selection.
2. Long press to save and exit.
3. Long press to enter the user settings.
Lock/Unlock
Enter Installer parameter settings
OR
+
++
LONG PRESS
LONG PRESS
OR
VS20WRF and VS20BRF Installer Manual 27
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 28
Installation - Graphics Key
28 VS20WRF and VS20BRF Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and long press to save and exit
Short press to back up
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 29
Installation – First Power Up
VS20WRF and VS20BRF Installer Manual 29
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 30
Installation - System Setup
System setup checklist
1
The Zigbee coordinator must be in pairing mode.
Before starting the pairing, make sure the light is ashing on the coordinator by holding the button for 5 seconds. For more information refer to the coordinator instruction manual.
2
The device that you intend to pair with must be ready to accept pairing.
Please refer to pages 33-45 and the relevant device installation guides.
30 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 31
Installation – System Parameters
SX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
SO1 System Unit 0 Programmable Stat (PRT)
Type 1 Digital Thermostat 0
2 HW Timer
S02 What does unit 0* It600 Wiring Centre*
Communicate 1 It600 radiator valve 0
within the iT600 2 System Receiver set for RX2
system 3** System Receiver set to RX1**
You are now ready to congure the unit
using the system parameter table below.
*Grouping is available on the wiring centre only please refer to page 6. Additionally you must have a PRT per group for grouping to operate. Two groups are the maximum
allowed per wiring centre.
** This setting is used when there is a system receiver only in the system. If there is a system receiver set to RX1 used along with wiring centre, radiator valves and system receiver set to RX2 then RX1 will communicate automatically to the thermostat connected to these other devices.
VS20WRF and VS20BRF Installer Manual 31
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 32
Installation - System Setup
32 VS20WRF and VS20BRF Installer Manual
Selecting what type of unit
Selecting what unit to pair with
Use or to select the type of unit. After selection has been made, press to conrm.
Use or to select the type of unit to pair with.
Programmable Stat (PRT)
Digital Thermostat
HW Timer
Wiring Centre.
Page 33
Radiator Valve.
Page 37
System Receiver Congured RX2.
Page 41
System Receiver
Only congure RX1.
Page 44
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 33
Installation - Pairing with Wiring Centre
Wiring Centre
Checklist
1
The Zigbee coordinator must be in pairing mode.
2
Ensure the wiring centre and optional system receiver (Congured to RX1) for remote boiler switch are powered up.
Note: The wiring centre and system receivers will automatically join Zigbee network when powered up and the Zigbee coordinator is in pair mode. Red LED on Wiring Centre and RX1 will go steady when the devices have joined the Zigbee network.
3
If more than one wiring centre is in the system, establish and note the wiring centre number by pressing the network key for 1 second. The wiring centre number will ash.
VS20WRF and VS20BRF Installer Manual 33
PAIRING
WITH WC
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:36 Stron
Page 34
Installation - Pairing with Wiring Centre
34 VS20WRF and VS20BRF Installer Manual
Use to select the wiring centre number to pair with.
If you are using groups, use to select group number of each group required. If unit is stand alone then please select --
Group 1
Group 1
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 35
Installation - Pairing with Wiring Centre
Long press to exit
to home screen
or continue to change device
settings. Refer to
page 57.
VS20WRF and VS20BRF Installer Manual 35
Use or to select the wiring centre zone number 1 to 8.
PAIRING
WITH WC
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 36
36 VS20WRF and VS20BRF Installer Manual
Installation - Testing the pairing with the RF WC
Use to increase temperature to 30ºC and then press
Use to decrease temperature to 10ºC and then press
If you are using the optional system receiver congured to RX1 please check that the green light goes on when the temperature is raised and o when reduced.
If pairing for your system is complete, please take the coordinator out of pair mode. Press for 5 seconds and light will stop ashing.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 37
VS20WRF and VS20BRF Installer Manual 37
Installation - Pairing the Radiator Valve(s)
Radiator
Valves
Checklist
1
The Zigbee coordinator must be in pairing mode.
2
Ensure that the radiator valves are in pairing mode (Refer to TRV10RF manual). A maximum of 3 radiator valves can be used with 1 thermostat. Pairing of radiator valve. Please pair TRV’s on a room by room basis.
3
If you are using the optional system receiver congured to RX1 for remote boiler switching. Ensure this has been powered up and the red ashing LED has gone steady.
PAIRING
WITH TRV
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 38
38 VS20WRF and VS20BRF Installer Manual
Installation - Pairing with Radiator Valve
Press to start the pairing process.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 39
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 57.
VS20WRF and VS20BRF Installer Manual 39
Installation - Pairing with the Radiator Valve
Once all TRV’s have paired press
The pre x
number on
the TRV will
change as the
TRV(s) pair.
PAIRING
WITH TRV
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 40
40 VS20WRF and VS20BRF Installer Manual
Installation - Testing RF Pairing
Use to increase temperature to 30ºC and then press
Use to decrease temperature to 10ºC and then press
If you are using the optional system receiver congured to RX1 please check that the green light goes on when the temperature is raised and o when reduced.
If pairing for your system is complete, please take the coordinator out of pair mode. Press for 5 seconds and light will stop ashing.
You should hear
the valve open. Once complete,
press key on
radiator valve
for 1 second.
You should hear
the valve open. Once complete,
press key on
radiator valve
for 1 second.
Green LED OPEN
Red LED CLOSED
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 41
VS20WRF and VS20BRF Installer Manual 41
Installation - Pairing with System Receiver RX2
System Receiver Congured to RX2 single room receiver.
Checklist
1
The coordinator must be in pairing mode.
2
The system receiver (RX2) is powered up and the red LED is steady. Refer to RX10RF manual.
3
If you are using the optional system receiver congured to RX1 for remote boiler switching. Ensure this has been powered up and the red ashing LED has gone steady. Refer to RX10RF manual.
Refer to system receiver manual.
PAIRING
WITH RX2
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 42
Installation - Pairing with System Receiver RX2
42 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 43
Installation - Testing Pairing with System Receiver RX2
Long press to exit to
home screen or
continue to change
device settings.
Refer to page 40.
VS20WRF and VS20BRF Installer Manual 43
Use to increase temperature to 30ºC and then press
Green LED on
Green LED o
Use to decrease temperature to 10ºC and then press
If you are using the optional system receiver congured to RX1 please check that the green light goes on when the temperature is raised and o when reduced.
If pairing for your system is complete, please take the coordinator out of pair mode. Press for 5 seconds and light will stop ashing.
PAIRING
WITH RX2
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 44
Installation - Pairing with System Receiver RX1 only
Checklist
1
The coordinator must be in pairing mode.
2
The system receiver (Congured to RX1) is powered up and the red LED is steady. The system receiver will auto join the Zigbee network on power up when the Zigbee coordinator is in pairing mode.
44 VS20WRF and VS20BRF Installer Manual
System Receiver congured to boiler receiver RX1. Refer to system receiver manual.
This conguration option is applicable if there is only a system receiver RX1 in the system.
Used if system receiver is used on its own.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 45
Installation - Pairing with System Receiver RX1 only
VS20WRF and VS20BRF Installer Manual 45
PAIRING
WITH RX1
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 46
46 VS20WRF and VS20BRF Installer Manual
Installation - Testing Pairing with System Receiver RX1 only
Long press to exit to home screen or
continue to change
device settings.
Refer to page 57.
Use to increase temperature to 30ºC and then press
Use to decrease temperature to 10ºC and then press
Green LED on
Green LED o
If pairing for your system is complete, please take the coordinator out of pair mode. Press for 5 seconds and light will stop ashing.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 47
Installation - Modifying System Parameters
If you have made an error or need to change your system parameters please follow steps below. This should only be done by your installer.
VS20WRF and VS20BRF Installer Manual 47
INSTALLATION
Press all three buttons
simultaneously
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 48
Unit will
follow power
up sequence
on page 29.
You are now ready to enter or change
your system parameters.
Refer to page 31.
48 VS20WRF and VS20BRF Installer Manual
Installation - Modifying System Parameters
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:37 Stron
Page 49
Press again for 1 second to cancel identify. Identify
mode will time out
after 10 minutes.
To check that the complete system is communicating and has been congured correctly, you can use identify mode.
Using identify from the coordinator will show all products that are connected to your system.
Installation - Checking System Conguration
INSTALLATION
VS20WRF and VS20BRF Installer Manual 49
Press for 1
second
to activate
identify mode.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 50
Installation - Checking System Conguration
PRT
PRT
Press tick to
cancel identify.
Identify mode
will time out
after 10 minutes.
System has no grouping
To check that the relevant system is communicating and has been congured correctly, you can use identify mode.
PRT PRT PRT PRT PRT
Please follow step 1 on page 47. When in identify mode all receivers and the coordinator related to the individual PRT will ash.
50 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 51
Group Control Thermostat
System has grouping
PRT
Please follow step 1 on page 47. When in identify mode all receivers, group thermostats and the coordinator will ash.
Group Control
Thermostat
Group
Thermostat
Group
Thermostat
Group
Thermostat
Press tick to
cancel identify.
Identify mode
will time out
after 10 minutes.
To check that the relevant system is communicating and has been congured correctly, you can use identify mode.
Installation - Checking System Conguration
VS20WRF and VS20BRF Installer Manual 51
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 52
Group Thermostat
System has grouping
PRT
Please follow step 1 on page 47. When in identify mode all receivers, control group thermostat and the coordinator will ash.
Group Control
Thermostat
Group
Thermostat
Group
Thermostat
Group
Thermostat
Press tick to
cancel identify.
Identify mode
will time out
after 10 minutes.
To check that the relevant system is communicating and has been congured correctly, you can use identify mode.
Installation - Checking System Conguration
52 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 53
Press again for 1 second to cancel identify. Identify
mode will time out
after 10 minutes.
To check that the complete system is communicating and has been congured correctly, you can use identify mode.
Using identify from the wiring centre will show all products that are connected to your wiring centre. Then wiring centre number will also be shown.
Installation - Checking System Conguration
VS20WRF and VS20BRF Installer Manual 53
INSTALLATION
Press for 5
second
to activate
identify mode.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 54
Installation - Checking System Conguration
PRT
PRT
Press tick to
cancel identify.
Identify mode
will time out
after 10 minutes.
System has no grouping
To check that the relevant system is communicating and has been congured correctly, you can use identify mode.
PRT PRT PRT PRT
Please follow step 1 on page 47. When in identify mode all radiator valves, receivers and the coordinator related to the individual PRT will ash.
54 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 55
Installation - Replacing product
Deleting Wiring Centre from the network.
Press for 15 seconds to delete the wiring centre
from the network.
All LED’s will ash
momentarily and then the wiring centre will be deleted from the network. All thermostats relating to the wiring centre will need to be recongured and paired with the new wiring centre.
If the wiring centre cannot be deleted as above, use the method below.
Please follow step 1 on page 47. Select password 46.
You are now
ready to
install your
new wiring
centre.
Before replacing any device it must be removed from the Zigbee network. Please ensure the Zigbee coordinator is also in pairing mode.
VS20WRF and VS20BRF Installer Manual 55
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 56
Installation - Replacing product
Before replacing any device it must be removed from the Zigbee network. Please ensure the Zigbee coordinator is also in pairing mode.
Note: If replacing a thermostat connected to the wiring centre, you can use the replacement method.
Deleting thermostat from the network.
Your thermostat will
now be deleted from
the network.
You are now ready to
install your new
thermostat.
Please note password
48 can also be used to
delete other devices
that are oine.
Please follow
step 1 on page
47. Select
password 48.
The unit
previously
connected to the
wiring centre
will be replaced.
56 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 57
Installation - Device parameters
Device parameters will follow system
parameters on rst
power up. If you
need to change
device parameters
follow the steps
below.
Please note, your
system parameters
will be shown rst
but cannot be
edited in this
section. To change
the system
parameters please
refer to page 47.
Press all three
buttons
simultaneously
VS20WRF and VS20BRF Installer Manual 57
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 58
Installation - Device Parameters
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D01 Heating 0 Pulse Width Modulation
Control 1 On-O 0.5 Deg C +/- 0.25 Deg C 0
2 On-O 1.0 Deg C +/- 0.5 Deg C
D02 Room -3.0 to 3.0 Temperature Oset from
Temperature Deg C Measured Temperature to 0 Deg C
Oset Compensate for any error
D03 Sensor probe or 0 Sensor/Cyl stat not Connected
Cylinder thermostat 1 Sensor/Cyl stat Connected 0
connection
D04 Sensor probe 0 D03 must be set to 1 then
used as air sensor external sensor be used as
or oor sensor Air sensor. There will be no
internal temp measurement
0
1 D03 must be set to 1 then
external sensor used for oor
protection. Internal temp is
measured by stat
D05 Cooling Control 1 On-O 0.5 Deg C +/- 0.25 Deg C
2
2 On-O 1.0 Deg C +/- 0.5 Deg C
D06 Actuator type 0 NO Normally Open
1
1 NC Normally Closed
D07 Valve protection 0 Disable
1
1 Enable
58 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 59
Installation - Device Parameters continued
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D08 Frost Set point 5-17 Deg C Required Temperature for frost 5 Deg
Temperature protection and holiday mode
D09 Hour Format 0 12
1
124
D10 N/A N/A N/A N/A
D11 Daylight Saving 0 OFF
1
Time (DST) 1 ON
D12 Heating Set point
5-35 Deg C
Maximum temp that can
35 Deg C
Limit be set for heating
D13 Cooling Set point
5-40 Deg C
Maximum temp that can
5 Deg C
Limit be set for Cooling
D14 Floor sensor High Output relay will be switched o
Limit Temperature 6-45 Deg C when temp is reached for 27 Deg C
oor protection
D15 Floor sensor Low Output relay will be switched on
Limit Temperature 6-45 Deg C when temp is reached for 10 Deg C
oor protection
D16 Floor sensor Limit Output relay will be switched o
for cooling 6-45 Deg C when temp is reached for 6 Deg C
oor protection
VS20WRF and VS20BRF Installer Manual 59
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 60
Installation - Error Codes
Error Code Prog Non-Prog HW
01 Comm Connection link failure Comm Connection link failure Comm Connection link failure
02 Comm Connection link failure Comm Connection link failure Comm Connection link failure
03 Floor sensor open Floor sensor open -
04 Floor sensor short Floor sensor short -
05 Prog/Non-prog/HW thermostat lost Prog/Non-prog/HW thermostat lost HW lost link with Coordinator
link with Coordinator (Displayed link with Coordinator (Displayed
on related Thermostat) Comm on related Thermostat) Comm
Connection link failure Connection link failure
06 Prog/Non-prog/HW thermostat Prog/Non-prog/HW thermostat HW lost link with WC
lost link with WC lost link with WC
(Displayed on related Thermostat) (Displayed on related Thermostat)
07 Prog/Non-prog Thermostat Prog/Non-prog Thermostat -
lost link with TRV lost link with TRV
(Displayed on related Thermostat) (Displayed on related Thermostat)
08 Prog/Non-prog Thermostat Prog/Non-prog Thermostat -
lost link with Receiver RX 1 lost link with Receiver RX 1
(Displayed on related Thermostat) (Displayed on related Thermostat)
09 Prog/Non-prog Thermostat Prog/Non-prog Thermostat -
lost link with Receiver RX 2 lost link with Receiver RX 2
(Displayed on related Thermostat) (Displayed on related Thermostat)
If there is more than 1 error, then on Error page, press UP to show other error codes. e.g. Err 03 05 ===> 3 errors Error code 05 ( 1st one ) Press Up to show Err 03 08 ===> 3 errors Error code 08 ( 2nd one ) Press Up again to show Err 03 09 ===> 3 errors Error code 09 ( 3rd one )
Press Up again to show Err 03 05 again......
Press OK to exit Error page back to Home display.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 61
Installation - Error Codes
Error Code Prog Non-Prog HW
10 WC lost link with hot water timer Comm Connection link failure Comm Connection link failure
(Displayed on all relevant thermostats (Displayed on all relevant thermostats (Displayed on all relevant thermostats
and also hot water timer) and also hot water timer) and also hot water timer)
11-18 WC lost link with zone Comm Connection link failure -
11=Zone 1, 12=Zone 2 etc 11=Zone 1, 12=Zone 2 etc
Displayed on all Displayed on all
connected thermostats connected thermostats
19 WC lost link with coordinator WC lost link with coordinator WC lost link with coordinator
(Displayed on all connected (Displayed on all connected (Displayed on all connected
thermostats and hot water timer) thermostats and hot water timer) thermostats and hot water timer)
20 WC lost link with receiver RX1 WC lost link with receiver RX1 WC lost link with receiver RX1
(Displayed on all connected (Displayed on all connected (Displayed on all connected
thermostats and hot water timer) thermostats and hot water timer) thermostats and hot water timer)
21 TRV lost link with coordinator TRV lost link with coordinator -
(Displayed on all connected (Displayed on all connected
thermostats) thermostats)
22 TRV low battery TRV low battery -
(Displayed on all connected (Displayed on all connected
thermostats) thermostats)
23 Invalid TRV Invalid TRV -
24 Unit is rejected by wiring centre Unit is rejected by wiring centre -
VS20WRF and VS20BRF Installer Manual 61
INSTALLATION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 62
Installation - Technical Detail
Model VS10RF / VS20RF Type Electronic programmable room thermostat, digital room thermostat
and hot water RF
Programming Modes User selectable for 5/2, ALL and Individual day options Program Number 1-6 Selectable Modes Party, Vacation, Program and Frost Override Permanent and temporary Frost Protection 5ºC Adjustable Power Source 230V AC 50Hz VS10RF - 4 x AAA VS20RF Temperature Scale 5 to 35ºC, tolerance 0.5ºC Heat/Cool Global changeover using communication bus and external input to
the wiring centre
Sensor Air or oor protection. Cylinder thermostat when congured for
hot water timer.
Device Parameters See page 57 Operating Temperature 0 to 50ºC Storage Temperature -20 to 60ºC Frequency 2.4HGz Zigbee
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 63
User Guide - Setting time and date
PRT and Group Control Thermostat
VS20WRF and VS20BRF Installer Manual 63
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 64
User Guide - Setting time and date
Use Left to select 12 hour and right to select 24 hour.
Adjust the time using the up or
down arrow key.
PRT and Group Control Thermostat
Hour
Minutes
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 65
User Guide - Setting time and date
PRT and Group Control Thermostat
Month
Year
Day
VS20WRF and VS20BRF Installer Manual 65
USER GUIDE
Adjust the
year/month/
day using the
up or down
arrow key.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 66
User Guide - Understanding Temperature Levels Heating
Highest Temperature typically used for early morning and early evening.
Typically 21 Deg C
Mid Temperature typically used for times of day when you are active around the home
Typically 19 Deg C
Lower Temperature typically used for unoccupied or sleep times. Typically 17 Deg
C for UFH or 15 Deg C for radiators
Frost Temperature typically used for Periods of long absence or holidays. Typically 5 Deg
Your thermostat comes preset for the above temperatures. These can be adjusted please see page 71
PRT, Group Control Thermostat and Group Thermostat
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 67
User Guide - Understanding Temperature Levels Cooling
Occupied Temperature. Typically 22ºC
Unoccupied Temperature Typically 40ºC
This avoids cooling being active when the property is unoccupied.
Evening Temperature Typically 24ºC
Your thermostat comes preset for the above temperatures. These can be adjusted please see page 71
Cooling is only available if your system supports this and the relevant congurations and connections have been made to the unit.
PRT, Group Control Thermostat and Group Thermostat
VS20WRF and VS20BRF Installer Manual 67
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 68
User Guide - Default Heating Schedule
21
19
17
12.00 7.00 9.00 17.00 23.00
Monday to Friday
21
19
17
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
PRT and Group Control Thermostat
If using grouping, the schedule from the group control thermostat will be applied to group members.
68 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 69
User Guide - Default Cooling Schedule
22
40
24
12.00 7.00 9.00 17.00 23.00
Monday to Friday
22
40
24
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
PRT and Group Control Thermostat
If using grouping, the schedule from the group control thermostat will be applied to group members.
VS20WRF and VS20BRF Installer Manual 69
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 70
User Guide - Graphics Key
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and long press to save and exit
Short press to back up
70 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 71
User Guide - Setting required temp levels
By setting the low
temperature the
program schedule
will use this as the
low setting.
The temperature
set are applicable
to the individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
Setting the low temperature
VS20WRF and VS20BRF Installer Manual 71
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 72
User Guide - Setting required temp levels
Repeat for
Move back to once temperature levels have been chosen.
By setting the
low temperature
the programs
will use this as
the low setting.
The temperature
set are
applicable to the
individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
72 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Page 73
User Guide – Setting the Temperature Schedule
Use right and left
to select the day
of the programs.
5/2
7 Days
Individual
If using grouping,
the schedule from
the group control
thermostat will be
applied to group
members.
VS20WRF and VS20BRF Installer Manual 73
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 74
User Guide – Setting the Temperature Schedule
Adjust the
time using the
up or down
arrow key.
Use right and
left to select the
Hi/Mid or low
temp.
74 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 75
User Guide – Setting the Temperature Schedule
When you set the temperature the schedule will respond to those temperatures see page 71 on how to change
Repeat through to program 4. If you require a 5th or 6th program enter a time and select your temperature
To remove a program out set the time to --:--.
VS20WRF and VS20BRF Installer Manual 75
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 76
User Guide - Temporary Override
Use the up or
down arrow key to
view your program
set temperature.
The temporary
override is applicable
to the thermostat
being changed only.
Use the up or down
arrow key to adjust the temperature to
the setting you
desire.
Temporary override allows you to increase the temperature or decrease it to the desired setting until it reverts back on the next program time.
PRT, Group Control Thermostat and Group Thermostat
76 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 77
User Guide - Temporary Override
To cancel temporary override press or See below.
PRT, Group Control Thermostat and Group Thermostat
Conrm the
temporary set
temperature.
VS20WRF and VS20BRF Installer Manual 77
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 78
User Guide - Permanent Override
To cancel permanent override select See below.
Permanent override in a control group thermostat will also aect the group thermostats unless they are removed from the group. See page 64.
Move from
To
Use the up or down arrow key to view your set
temperature.
See page 71.
To adjust your permanent override temperature, follow
the steps on page 71.
Repeat for
if required
PRT and Group Control Thermostat
Setting permanent low temperature
78 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 79
User Guide - Party Mode
The party mode is
an option that
enables
temperature
for a period of
time you select
up to 9hr 50min.
Use the right arrow to select the party mode.
Use the up arrow to select the hr/min.
Press tick to conrm and it will start to count down .
Party Mode set in
a Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from
the group.
See page 64.
PRT and Group Control Thermostat
VS20WRF and VS20BRF Installer Manual 79
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 80
User Guide - Holiday Mode
Use the right arrow to select the holiday mode.
Use the up arrow to select how many days to be o for .
Press tick to conrm and it will start the holiday count down.
Holiday set in a
Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from
the group.
See page 82.
80 VS20WRF and VS20BRF Installer Manual
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 81
User Guide - Frost Protection
Use the right arrow to select the frost mode.
Use the up arrow to select the frost protection temperature.
Press tick to conrm the temperature that has been set to.
Frost protection
set in a Control
Group Thermostat
will also aect
group thermostats
unless they are
removed from the
group.
See page 82.
VS20WRF and VS20BRF Installer Manual 81
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 82
User Guide - Group Thermostat Overview
When a group thermostat is in it will follow the mode status of the group control thermostat.
When a group thermostat is in and the group control thermostat is in
or then the group thermostat will follow this mode.
or will be
displayed.
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 71.
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 71.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 83
User Guide - Group Thermostat Overview
The group thermostat has now left the
group and is in permanent To adjust
the set temperature, please refer to page 71.
The group thermostat has now left the
group and is in permanent To
adjust the set temperature,
please refer to page 71.
The group thermostat has been
returned to it will follow
the mode status of the group
control thermostat.
VS20WRF and VS20BRF Installer Manual 83
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 84
User Guide - Hot Water (Optional) Mode Selection
2
3
Mode selection
Hot water will
follow Holiday
mode from the
group control
thermostat.
will be
displayed.
When is
selected, the hot
water timer will
follow the
program schedule.
See page 86.
Hot water will be on once per day.
Hot water will be continuously on.
Hot water will be continuously o.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 85
User Guide - Hot Water Boost
VS20WRF and VS20BRF Installer Manual 85
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 86
User Guide - Default Hot Water Schedule
12.00
6.00 8.00 18.00 22.00
ON ON
OFFOFF OFF
12.00 6.00 8.00 18.00 22.00
Saturday and Sunday
Monday to Friday
ON ON
OFFOFF OFF
Your hot water timer comes preset with the times below. These can be adjusted. See next page.
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 87
User Guide - Setting Hot Water Times
5/2
7 Days
Individual
USER GUIDE
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 88
User Guide - Setting Hot Water Times
Repeat these steps for programs
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 89
User Guide - Setting Hot Water Times
VS20WRF and VS20BRF Installer Manual 89
USER GUIDE
Repeat these steps for programs
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 90
Installer Notes
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 91
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specication, for a period of ve years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: ..................................................................................................................
Customer Address: ...............................................................................................................
......................................................................... Post Code: ..................................................
Tel No: ..................................................... Email: .................................................................
Engineers Company: ............................................................................................................
Tel No: ....................................................... Email: ...............................................................
Instalation Date: ..................................................................................................................
Engineers Name: .................................................................................................................
Engineers Signature: ...........................................................................................................
VS20WRF and VS20BRF Installer Manual 91
Warranty
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Page 92
www.salus-controls.com
SALUS Controls plc
SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 0 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 0 1226 323961
E: tech@salus-tech.com
For PDF Installation guide please go to www.salus-controls.com
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
00086/2 Issue Date: June 2014
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:39 Stron
Loading...