Salus VS10W, VS10B Installer's/user's Manual

Page 1
4 in 1 Digital Thermostat Control
Models: VS10W and VS10B
INSTALLER / USER MANUAL
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 2
02 VS10W and VS10B Installer Manual
1 x Installer / User manual VS10W VS10BFixing screws
Contents
Box contents Introduction Product Compliance System options overview Installation Parameter Settings Error Codes User Guide Installers notes Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation guide please go to www.salus-controls.com
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 3
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing the SALUS 4 in 1 digital room thermostat VS10. To maximise the features the unit, it should be used with the SALUS Wiring Centre KL10.
The unit can be congured to be a Programmable Thermostat (PRT), Group Control Thermostat, Group Thermostat or hot water timer. The units can communicate with each other (including VS05 Dial Thermostat) when connected to the wiring centre and using the communication connections. More information can be found on pages 9 and 10.
Product Compliance
This product is CE compliant and meets the following EC Directives Electro-Magnetic Compatibility directive 2004/108/EC Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations The SALUS VS10 is to be used for for room control of heating and hot water systems inside the house.
SALUS Wiring Centre KL10
We hope you enjoy this product...
VS10W and VS10B Installer Manual 03
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 4
Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains supply before removing the cover.
Emergency
Switch o the voltage to the individual thermostat wring centre or complete system.
Installer parameter settings
The SALUS VS10 is equipped with installer parameter section (see page 40) this must only be entered by the installer or competent person. Changing these parameters can have a serious eect on your heating system
For the installer
Please enter any parameter changes in the installer notes section (pages 72 - 74)
230V AC
04 VS10W and VS10B Installer Manual
These instructions are applicable to the SALUS model stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 5
VS10W and VS10B Installer Manual 05
System Overview - Conguration Options
Programmable Room
Thermostat (PRT)
The unit can be congured to either one of the following
1
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
Group Control
Thermostat
2
Group
Thermostat
3
Timer
4
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 6
System Overview - Conguration Options
06 VS10W and VS10B Installer Manual
Programmable Room Thermostat (PRT)
When congured for PRT (see page 31) it mainly works by itself and allows the user to have separate Time and Temperature control of each zone on the wiring centre. Features like Vacation , Party frost mode have to set on each individual thermostat. The PRT can be congured for global Heat/Cool system changeover if your system supports this. This is achieved from a switched input from the wiring centre (see note 6 from the wiring center installation guide). Communication Connection (see page 13) is required to use heat/cool changeover function
Group Control Thermostat
When congured for a group control thermostat (see page 33) this allows central control of up to 7 group thermostats see below, there can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature override, Holiday, Party, Frost modes, can be selected centrally from the Group Control Thermostat. Holiday will also be applied to a timer if applicable. Communication connections (see page 13) are required for grouping the group thermostats. Thermostats can be also globally changed from heating to cooling thermostats if you system supports this by using the switched input connection on the WC (see note 6 from the wiring center installation guide) along with the communications connections mentioned above
Group Thermostat
When congured for Group thermostat (see page 36) and in group mode the group thermostat will follow the time schedule and any override modes of the group thermostat. The Group thermostat can have its own programd temperatures, manual override and also be removed from the group temporarily or permanently. Communication connections required (see page 13).
Timer
When congured to timer (see pages 32 & 34) the unit will operate as a timer with no temp control. This can be used for example hot water control. The timer will also follow Holiday mode from the group control thermostat if applicable, communication connections required for this group function.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 7
System Overview - Cables
Power and Switching Cable – used to power thermostats and drive output
Grouping and Communication cable
Communication cable can be used when units are used as individual PRT's for heat/cool changeover. Please refer to page 13 and note 5 on the wiring centre installation guide.
While the thermostats can function as stand alone Programmable or Timer’s, Installing this Optional inexpensive Communication Cable allows the thermostats to communicate with each other. This allows the thermostat to assume convenient remote control of groups of thermostats. Bringing central control of features such as Time control, Holiday & Party functions as well as frost control. The individual group members can leave or re-enter group control at the push of a button
Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication.
VS10W and VS10B Installer Manual 07
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 8
System Overview - Options
Option 1 - Page 09
Option 2 - Page 10
Option 3 - Page 10
The systems below although not exhaustive show the main options. The maximum number of groups per KL10 wiring centre is two. The group selection communication cable must correspond to the group terminals on the KL10 WC. Please refer to note 5 on the KL10 installation guide.
Group 1 Group 2
Group 1
Group 2
All Digital Variants can be congured from VS10. Groups must have a group control thermostat. 1 or 2 Groups can be used per wiring centre. HW Timer can be stand alone or part of a group. If using HW Timer as part of a group it must be in group 1.
08 VS10W and VS10B Installer Manual
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 1 - Unit is congured as individual PRT.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 9
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - PRT
Individual Room Control 4 4 Individual Holiday Function 4 4 Individual Party Function 4 4 Individual Heating Program 4 4 Individual Frost Function 4 4 Group Holiday including HW 6 6 Group Party 6 6 Group Heating Program 6 6 Group Permanent Override 6 6 Group Temporary Override 6 6 Heat/Cool changeover 6 4
Note: The communication connection is only used for heat/cool changeover when using units congured to PRT’s and using the relevant connection on the KL10 Wiring Centre. Please refer to note 6 on Wiring Centre installation guide.
Option 1 - Page 31
VS10W and VS10B Installer Manual 09
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 10
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION CONNECTION - GROUP CONTROL
Individual Room Control 4 4 Individual Holiday Function 4 4 Individual Party Function 4 4 Individual Heating Program 4 4 Individual Frost Function 4 4 Group Holiday including HW 6 4 Group Party 6 4 Group Heating Program 6 4 Group Permanent Override 6 4 Group Temporary Override 6 4 Heat/Cool changeover 6 4
Note HW timer will only use HOLIDAY function when the communication connection is used. Also the HW timer must be connected to GROUP 1 communication terminals on wiring centre. See note 8 on Wiring Centre installation guide.
Option 2 - Page 33 Option 3 - Page 35
10 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 11
System Overview - Hot Water Option
When the unit is congured as a hot water timer (see page 34) there are two methods of connecting the cylinder thermostat
Unit congured to Hot Water Timer.
Cylinder thermostat options
1 Connected direct to WC (Default)
2 Connected direct to VS10 (requires additional
parameter change. See page 40)
VS10W and VS10B Installer Manual 11
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 12
System Overview - Hot Water Option
1 Connected direct to WC (Default) 2 Connected direct to VS10
(requires additional parameter change see page 40)
For convenience there is a unique built in option allowing the cylinder thermostat to be connected to either the HW Timer or Wiring Centre.
Please refer to note 1 on Wiring Centre guide and page 18 for more information.
12 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 13
Installation – Terminal Connections
Understanding your terminal connections
Rear of unit
Communication Terms 12VDC
Two wire twisted pair can be used for Grouping Functions between PRT, Group Control Thermostat, Group Thermostat and HW Timer.
Power Terminals 230 Vac
Used for supplying power to the unit and switched output.
Sensor Terminals
Can be used for external AIR, Floor sensor when congured as thermostat. Can also be used for Cylinder thermostat when congured for HW.
1
3
2
1 2 3
VS10W and VS10B Installer Manual 13
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 14
Carefully remove the front housing.
Installation – Thermostat Mounting
1 3
2
60mm
14 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 15
Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the unit is best positioned in a draft free area and at 130cm from the oor. Do not position the thermostat near any heat source, behind curtains, direct sunlight or an area of high humidity.
VS10W and VS10B Installer Manual 15
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 16
Installation – Thermostat Connections
While the thermostats can function as PRT or Timer’s, Installing this Optional inexpensive Communication Cable allows the thermostats to communicate with each other. This allows the thermostat to assume convenient remote control of groups of thermostats. Bringing central control of features such as Time control, Holiday & Party functions as well as frost control. The individual group members can leave or re­enter group control at the push of a button
Optional communication connection 12VBC
For more detail refer to note 5 on the wiring centre installation guide
16 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 17
Installation – Thermostat External Sensor
Note: If you are using an external sensor, the unit has to be congured for External Air Sensor or Floor Protection Sensor please see device parameter setting page 40.
VS10W and VS10B Installer Manual 17
INSTALLATION
SALUS External sensor (Sold separately)
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 18
Installation – Hot Water Timer wiring
Power Connections 230 Vac
Optional
Communication
Connections 12 VDC
If hot water is part of a group then the communication connection must be connected to group 1.
18 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 19
Installation – Hot Water Timer Cylinder Thermostat
Note: The unit can be congured for Cylinder thermostat or connected to the Hot Water Timer. Please see device parameters page 40. For additional Wiring Centre information refer to note 1 on Wiring Centre guide.
HW Timer connected cylinder thermostat
IN OUT
Link must be tted
WC connected cylinder thermostat (Default)
Cylinder thermostat SALUS CT100
IN OUT
VS10W and VS10B Installer Manual 19
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 20
Installation – Thermostat Mounting
Check that the wiring is completed for:
1
2
3
Please use the screws provided
Ensure the orientation arrow is pointing upwards.
Power Terminals
Sensor Terminals (if applicable)
Communication connections (optional but recommended)
You are ready to secure the rear housing to the wall box
20 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 21
Installation – Thermostat Mounting
1
Fit the front housing to the rear housing
Align the front housing at the bottom edge.
2
Lightly press until you hear a positive click.
Ensure the pin connections are aligned
VS10W and VS10B Installer Manual 21
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 22
Installation – LCD Graphics
ICON FUNCTION
BOX means to select the mode e.g. means the current setpoint is Hi temp, means the Hi temp is not selected.
Sunny: Hi comfortable temperature.
Cloudy: Middle comfortable temperature.
Moon: Low comfortable temperature.
Programmable thermostat Program mode indicator:
Indicates program is running, Auto On or Auto O. For group thermostat this indicates that it is a member of a group.
Party indicator:
When Party mode is active.
Vacation indicator:
When Vacation mode is active
Frost protection indicator:
Frost protection is active, not available in cooling mode (if applicable)
22 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 23
Installation – LCD Graphics
ICON FUNCTION
Heat indicator:
Indicates heat is required.
Cool mode indicator:
Indicates cooling is required (if applicable)
Temperature indicator:
Display the room temperature. Display the set-temp. Also used to show the other information.
Temporary manual override indicator:
If the set temperature is changed when in program mode, the hand will appear until the next program start time.
Programs number indicator:
In AUTO program mode or Temporary override is running, it means the current program running.
Day indication:
1 = Monday
VS10W and VS10B Installer Manual 23
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 24
Installation – LCD Graphics
ICON FUNCTION
Hot Water (HW) indicator:
Unit has been congured for HW Timer.
Hot Water (HW) indicator:
Indicates that there is Hot Water demand.
HW Program mode indicator:
Indicates program is running.
HW Mode indicator:
Mode for 1 period of HW a day, from Program 1 ON to Program 3 OFF.
HW Mode indicator:
Indicates continuously On.
HW Mode indicator:
Indicates continuously O.
HW Mode indicator:
Indicates Boost +1hr override.
24 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 25
Installation – LCD Graphics
ICON FUNCTION
Floor sensor probe indicator
Show only when Air + Floor sensor is connected.
Low battery indicator:
Batteries need to be replaced.
Setting indicator:
Indicate the unit is in setting mode when program setting. Indicate the manual mode.
Keylock indicator:
Shows that keys are inactive.
VS10W and VS10B Installer Manual 25
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 26
Installation – User Interface
KEY FUNCTION
1. Increase or decrease setpoint temperature.
2. Increase or decrease Day, Clock, Timer, Party, Holiday and Boost.
3. Select installer parameter value.
1. Mode selection.
2. Long press to return to home display without saving.
3. Short press to return to the previous screen when it is in user/ installer setting mode.
1. OK key: Short press to conrm selection.
2. Long press to save and exit.
3. Long press to enter the user settings.
Lock/Unlock
Enter Installer parameter settings
Test mode
OR
+
++
LONG PRESS
LONG PRESS
LONG PRESS
+
OR
26 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 27
Installation – First Power Up
VS10W and VS10B Installer Manual 27
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 28
Installation – System Parameters
SX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
SO1 System Unit 0 Programmable Stat (PRT)
Type 1 Digital Thermostat 0
2 HW Timer
S03 System 0** PRT only with communication*
Communication 1* Group control thermostat and
group thermostat communication 1
2 No Communication /
Grouping required
You are now ready to congure the unit
using the system parameter table below.
*S03 setting 1 is used for Control Group options 2 & 3 see pages 33-36, communication
connection must be used, global heat/cool changeover is also included if applicable to your system.
**S03 setting 0 is used for option 1 (see page 31) when heat/cool changeover is required for individual PRT’s, communication connections must be used for this function. S03 setting 0 is only available if setting 0 has been selected for S01. If no heat/cool changeover is required when using PRT’s only then select setting 2 for S03
28 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 29
Installation - Options
Option 1 - Page 31
Option 2 - Page 33
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 3 - Page 35
Group 1 Group 2
Group 1
Group 2
An additional Hot Water Timer can be used with any of the above options
Option 1 - Unit is congured as individual PRT.
VS10W and VS10B Installer Manual 29
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 30
Installation - Graphics Key
30 VS10W and VS10B Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and long press to save and exit
Short press to back up
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 31
Option 1 - Individual Programmable thermostat setup
VS10W and VS10B Installer Manual 31
Long press to exit
to home screen
or continue to change device
settings. Refer to
page 33.
Short press on
to back up.
Use to change to 2.
PRT with no communication*
*Select S03 setting 0 if communication is required for global heat/cool changeover. Your system must support this and the communication connection must be used. See page 13.
SYSTEM OPTION 1
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 32
Option 1 - Hot Water Timer (Optional ) Conguration
Long press to exit
to home screen
or continue to change device
settings. Refer to
page 40.
Hot water with no communication.
32 VS10W and VS10B Installer Manual
Use to change to 2.
Use to change to 2.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 33
Option 2 - Thermostat Conguration
Group Control Thermostat
VS10W and VS10B Installer Manual 33
Long press to
exit to home
screen or
continue to change device settings. Refer
to page 40.
Communication
connection
required for this
setting.
SYSTEM OPTION 2
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 34
Option 2 - Hot Water Timer (Optional) Conguration
34 VS10W and VS10B Installer Manual
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 40.
Communication
connection
required for this
setting.
Use to change to 2.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 35
Option 3 - Thermostat Conguration
VS10W and VS10B Installer Manual 35
SYSTEM OPTION 3
Group Control Thermostat
Long press to
exit to home
screen or
continue to change device settings. Refer
to page 40.
Communication
connection
required for this
setting.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 36
Option 3 - Thermostat Conguration
36 VS10W and VS10B Installer Manual
Group Thermostat
Long press to
exit to home
screen or
continue to change device settings. Refer
to page 40.
Communication
connection
required for this
setting.
Use to change to 1.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 37
Option 3 - Hot Water Timer (Optional) Conguration
VS10W and VS10B Installer Manual 37
SYSTEM OPTION 3
Long press to
exit to home
screen or
continue to change device settings. Refer
to page 40.
Communication
connection
required for this
setting.
Use to change to 2.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 38
38 VS10W and VS10B Installer Manual
Installation - System Parameters
If you have made an error or need to change your system parameters please follow steps below. This should only be done by your installer.
Press all three
buttons
simultaneously
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 39
Installation - System Parameters
Unit will follow
power up
sequence on
page 27.
You are now
ready to enter or
change your
system
parameters.
Refer to page
28.
VS10W and VS10B Installer Manual 39
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 40
Installation - Device parameters
Device parameters will follow system parameters on rst power up. If you need to change device parameters follow the steps below.
Please note, your system parameters will be shown rst but cannot be edited in this section. To change the system parameters please refer to the previous two pages.
40 VS10W and VS10B Installer Manual
Press all three
buttons
simultaneously
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 41
Installation - Device Parameters
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D01 Heating 0 Pulse Width Modulation
Control 1 On-O 0.5 Deg C +/- 0.25 Deg C 0
2 On-O 1.0 Deg C +/- 0.5 Deg C
D02 Room -3.0 to 3.0 Temperature Oset from
Temperature Deg C Measured Temperature to 0 Deg C
Oset Compensate for any error
D03 Sensor probe or 0 Sensor/Cyl stat not Connected
Cylinder thermostat 1 Sensor/Cyl stat Connected 0
connection
D04 Sensor probe 0 D03 must be set to 1 then
used as air sensor external sensor be used as
or oor sensor Air sensor. There will be no
internal temp measurement
0
1 D03 must be set to 1 then
external sensor used for oor
protection. Internal temp is
measured by stat
D05 Cooling Control 1 On-O 0.5 Deg C +/- 0.25 Deg C
2
2 On-O 1.0 Deg C +/- 0.5 Deg C
D06 Actuator type 0 NO Normally Open
1
1 NC Normally Closed
D07 Valve protection 0 Disable
1
1 Enable
VS10W and VS10B Installer Manual 41
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 42
Installation - Device Parameters continued
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D08 Frost Set point 5-17 Deg C Required Temperature for frost 5 Deg
Temperature protection and holiday mode
D09 Hour Format 0 12
1
124
D10 N/A N/A N/A N/A
D11 Daylight Saving 0 OFF
1
Time (DST) 1 ON
D12 Heating Set point
5-35 Deg C
Maximum temp that can
35 Deg C
Limit be set for heating
D13 Cooling Set point
5-40 Deg C
Maximum temp that can
5 Deg C
Limit be set for Cooling
D14 Floor sensor High Output relay will be switched o
Limit Temperature 6-45 Deg C when temp is reached for 27 Deg C
oor protection
D15 Floor sensor Low Output relay will be switched on
Limit Temperature 6-45 Deg C when temp is reached for 10 Deg C
oor protection
D16 Floor sensor Limit Output relay will be switched o
for cooling 6-45 Deg C when temp is reached for 6 Deg C
oor protection
42 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 43
Installation - Error Codes
Error Code Prog Non-Prog HW
01 Comm Connection link failure Comm Connection link failure Comm Connection link failure
02 Comm Connection link failure Comm Connection link failure Comm Connection link failure
03 Floor sensor open Floor sensor open -
04 Floor sensor short Floor sensor short -
If there is more than 1 error, then on Error page, press UP to show other error codes. e.g. Err 03 05 ===> 3 errors Error code 05 ( 1st one ) Press Up to show Err 03 08 ===> 3 errors Error code 08 ( 2nd one ) Press Up again to show Err 03 09 ===> 3 errors Error code 09 ( 3rd one )
Press Up again to show Err 03 05 again......
Press OK to exit Error page back to Home display.
VS10W and VS10B Installer Manual 43
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 44
Installation - Technical Detail
Model VS10W/ VS10B Type Electronic programmable room thermostat, digital room
thermostat and hot water timer designed for 230V AC applications
Programming Modes User selectable for 5/2, ALL and Individual day options Program Number 1-6 Selectable Modes Party, Vacation, Program and Frost Override Permanent and temporary Frost Protection 5ºC Adjustable Power Source 230V AC 50Hz Rating 3 Amp Communication Bus 12V DC Temperature Scale 5 to 35ºC, tolerance 0.5ºC Heat/Cool Global changeover using communication bus and external input
to the wiring centre
Sensor Air or oor protection. Cylinder thermostat when congured for
hot water timer.
Device Parameters See page 40 for full list of functions Operating Temperature 0 to 50ºC Storage Temperature -20 to 60ºC
44 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 45
User Guide - Setting time and date
VS10W and VS10B Installer Manual 45
USER GUIDE
PRT and Group Control Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 46
User Guide - Setting time and date
Use Left to select 12 hour and right to select 24 hour.
Adjust the time
using the up or
down arrow key.
46 VS10W and VS10B Installer Manual
PRT and Group Control Thermostat
Hour
Minutes
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 47
User Guide - Setting time and date
Adjust the
year/month/day
using the up or
down arrow key.
VS10W and VS10B Installer Manual 47
USER GUIDE
PRT and Group Control Thermostat
Month
Year
Day
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 48
User Guide - Understanding Temperature Levels Heating
48 VS10W and VS10B Installer Manual
Highest Temperature typically used for early morning and early evening.
Typically 21 Deg C
Mid Temperature typically used for times of day when you are active around the home
Typically 19 Deg C
Lower Temperature typically used for unoccupied or sleep times. Typically 17 Deg
C for UFH or 15 Deg C for radiators
Frost Temperature typically used for Periods of long absence or holidays. Typically 5 Deg
Your thermostat comes preset for the above temperatures. These can be adjusted please see page 53
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 49
User Guide - Understanding Temperature Levels Cooling
Occupied Temperature. Typically 22ºC
Unoccupied Temperature Typically 40ºC
This avoids cooling being active when the property is unoccupied.
Evening Temperature Typically 24ºC
VS10W and VS10B Installer Manual 49
Your thermostat comes preset for the above temperatures. These can be adjusted please see page 53
Cooling is only available if your system supports this and the relevant congurations and connections have been made to the unit.
USER GUIDE
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 50
User Guide - Default Heating Schedule
50 VS10W and VS10B Installer Manual
21
19
17
12.00 7.00 9.00 17.00 23.00
Monday to Friday
21
19
17
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
PRT and Group Control Thermostat
If using grouping, the schedule from the group control thermostat will be applied to group members.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 51
User Guide - Default Cooling Schedule
22
40
24
12.00 7.00 9.00 17.00 23.00
Monday to Friday
22
40
24
12.00 8.00 9.00 17.00 23.00
Saturday to Sunday
VS10W and VS10B Installer Manual 51
USER GUIDE
PRT and Group Control Thermostat
If using grouping, the schedule from the group control thermostat will be applied to group members.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 52
User Guide - Graphics Key
52 VS10W and VS10B Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and long press to save and exit
Short press to back up
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 53
User Guide - Setting required temp levels
By setting the
low temperature
the program
schedule will use
this as the low
setting.
The temperature
set are
applicable to the
individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
Setting the low temperature
VS10W and VS10B Installer Manual 53
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 54
User Guide - Setting required temp levels
Repeat for
Move back to once temperature levels have been chosen.
By setting the
low temperature
the programs
will use this as
the low setting.
54 VS10W and VS10B Installer Manual
The temperature
set are
applicable to the
individual
thermostat.
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 55
User Guide – Setting the Temperature Schedule
Use right and left
to select the day
of the programs.
VS10W and VS10B Installer Manual 55
5/2
7 Days
Individual
If using grouping, the schedule from the group control thermostat will be applied to group members.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 56
User Guide – Setting the Temperature Schedule
Adjust the time using the up or
down arrow key.
Use right and left to select the Hi/Mid or
low temp.
56 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 57
User Guide – Setting the Temperature Schedule
When you set the temperature the schedule will respond to those temperatures see page 53 on how to change
Repeat through to program 4. If you require a 5th or 6th program enter a time and select your temperature
To remove a program out set the time to --:--.
VS10W and VS10B Installer Manual 57
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 58
User Guide - Temporary Override
Use the up or down
arrow key to view
your program set
temperature.
The temporary
override is applicable
to the thermostat
being changed only.
Use the up or down
arrow key to adjust the temperature to
the setting you
desire.
Temporary override allows you to increase the temperature or decrease it to the desired setting until it reverts back on the next program time.
58 VS10W and VS10B Installer Manual
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 59
User Guide - Temporary Override
To cancel temporary override press or See below.
VS10W and VS10B Installer Manual 59
PRT, Group Control Thermostat and Group Thermostat
Conrm the
temporary set
temperature.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 60
User Guide - Permanent Override
To cancel permanent override select See below.
Permanent override in a control group thermostat will also aect the group thermostats onless they are removed from the group. See page 64.
Move from to
Use the up or
down arrow key to
view your set
temperature. See
page 58.
To adjust your
permanent
override
temperature,
follow the steps
on page 58.
Repeat for
if required
60 VS10W and VS10B Installer Manual
PRT and Group Control Thermostat
Setting permanent low temperature
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 61
User Guide - Party Mode
The party mode is an option that enables temperature for a period of time you select up to 9hr 50min.
Use the right arrow to select the party mode.
Use the up arrow to select the hr/min.
Press tick to conrm and it will start to count down .
Party Mode set in a Control Group Thermostat will also aect group thermostats unless they are removed from the group. See page 64.
VS10W and VS10B Installer Manual 61
USER GUIDE
PRT and Group Control Thermostat
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 62
User Guide - Holiday Mode
Use the right arrow to select the holiday mode.
Use the up arrow to select how many days to be o for .
Press tick to conrm and it will start the holiday count down.
62 VS10W and VS10B Installer Manual
Holiday set in a Control Group Thermostat will also aect group thermostats unless they are removed from the group. See page 64.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 63
User Guide - Frost Protection
Use the right arrow to select the frost mode.
Use the up arrow to select the frost protection temperature.
Press tick to conrm the temperature that has been set to.
VS10W and VS10B Installer Manual 63
Frost protection set in a Control Group Thermostat will also aect group thermostats unless they are removed from the group. See page 64.
Frost protection is not available in cooling. Moving the
to this position in cooling will switch the thermostat to o.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 64
User Guide - Group Thermostat Overview
When a group thermostat is in it will follow the mode status of the group control thermostat.
When a group thermostat is in and the group control thermostat is in
or then the group thermostat will follow this mode.
or will be
displayed.
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 58.
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 58.
64 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 65
User Guide - Group Thermostat Overview
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 58.
The group thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 58.
The group thermostat has been returned to it will follow the mode status of the group control thermostat.
VS10W and VS10B Installer Manual 65
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 66
User Guide - Hot Water (Optional) Mode Selection
66 VS10W and VS10B Installer Manual
2
3
Mode selection
Hot water will follow Holiday mode from the group control thermostat.
will be displayed.
When is selected, the hot water timer will follow the program schedule. See page 68.
Hot water will be on once per day.
Hot water will be continuously on.
Hot water will be continuously o.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 67
User Guide - Hot Water Boost
VS10W and VS10B Installer Manual 67
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 68
User Guide - Default Hot Water Schedule
12.00
6.00 8.00 18.00 22.00
ON ON
OFFOFF OFF
12.00 6.00 8.00 18.00 22.00
Saturday and Sunday
Monday to Friday
ON ON
OFFOFF OFF
Your hot water timer comes preset with the times below. These can be adjusted. See next page.
68 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 69
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 69
USER GUIDE
5/2
7 Days
Individual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 70
User Guide - Setting Hot Water Times
70 VS10W and VS10B Installer Manual
Repeat these steps for programs
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 71
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 71
USER GUIDE
Repeat these steps for programs
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 72
Installer Notes
72 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 73
Installer Notes
VS10W and VS10B Installer Manual 73
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 74
Installer Notes
74 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 75
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specication, for a period of ve years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: .............................................................................................................................
Customer Address: ..........................................................................................................................
............................................................................... Post Code: ........................................................
Tel No: ........................................................ Email: .........................................................................
Engineers Company: .......................................................................................................................
Tel No: ......................................................... Email: ........................................................................
Instalation Date: ..............................................................................................................................
Engineers Name: ............................................................................................................................
Engineers Signature: .......................................................................................................................
VS10W and VS10B Installer Manual 75
Warranty
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
Page 76
www.salus-controls.com
SALUS Controls plc
SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 0 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 0 1226 323961
E: tech@salus-tech.com