Salus KL10RF Installation And Wiring Manual

KL10RF
Installation and wiring guide
www.salus-controls.com Technical Helpline 00000 000000
LN
1
2
LN
1
2
1
2
LN
1
2
OUT
IN
OPTIONAL UFH ZONE VALVE
FOR RADIATORS GROUPS
FUSE
FUSE
SUPPLIED CABLES
230V TO UFH PUMP
UNDERFLOOR HEATING MANIFOLD
1.5MM2CABLE
(INSTALLER SUPPLIED)
1.5MM
2
CABLE
(INSTALLER SUPPLIED)
1.5MM
2
CABLE
(INSTALLER SUPPLIED)
1.5MM
2
CABLE
(INSTALLER SUPPLIED)
13 AMP FUSED CONNECTION UNIT
FUSED AT 3 AMPS
230V
OPTIONAL
CYLINDER STAT
1.5MM23 CORE
1.5MM
2
3 CORE
1.5MM
2
CABLE
OUT
IN
(INSTALLER SUPPLIED)
COLOURS ARE INDICATIVE ONLY. EXTRA CONNECTIONS MAY BE REQUIRED AS PER MANUFACTURERS INSTRUCTIONS
ZONE 1
+++++++++
---------
ZONE 2
IN
HW CYLINDER THERMOSTAT
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT IN OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
ZONE 3 ZONE 4 ZONE 5
ZONE 6
ZONE 7
ZONE 8
LN
1
2
LNLN LNLN LNLN
THERMOSTAT NEUTRAL CONNECTIONS THERMOSTAT LIVE CONNECTIONS
L NLNLNLNLNLNLNLNLNLN
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
(MODEL VS20WRF)
OPTIONAL HOT WATER TIMER (MODEL VS10WRF
or VS20WRF)
MAINS POWERED PROGRAMMABLE
ROOM THERMOSTAT
(MODEL VS10WRF)
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
MAINS POWERED PROGRAMMABLE
ROOM THERMOSTAT
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
MAINS POWERED PROGRAMMABLE
ROOM THERMOSTAT
(MODEL VS20W
RF
(
MODEL VS10WRF
)
OPTIONAL
PROGRAMMABLE
ROOM THERMOSTAT
RADIATOR ZONE
RADIATOR ZONE
or VS20WRF)
2
2
1
3
4
8
6
5
9
FACTORY FITTED
LINK
FACTORY FITTED
LINK
FACTORY FITTED
LINK
These instructions are applicable to the SALUS model stated above.
Warning
This product must be tted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.
For PDF Installation guide please go to www.salus-controls.com
Meets the following EC Directives
• Electro-Magntic Compatibility directive 2004 / 108 / EC
• Low voltage Directive 2006/95/EC
Optional wireless
receiver RX10RF
7
Maintaining a policy of continued product development SALUS Controls plc reserve the right to change specication, design and materials of products listed on this installation guide without prior notice.
Issue Date: June 2014 Document Number 00106
iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 1
KL10RF
Installation and Wiring Guide
When using option 2 refer to device
parameters on page xx of the manual.
Fuses
Coordinator
Aerial Connection
Dip Switch Set Up
In order for the wiring centre to be able to control UFH and Radiators, there is a need to turn o the UFH pump for a zone when that zone is to be used for radiators.
Eg. When tting a zone for radiators or towel rail then the Dip Switch for that zone should be switched to OFF. The Dip Switches for this are located under the front lid. When the zone switch is in the ON position the UFH pump will run when that zone is calling for heat along with the boiler. When it is in the OFF position then the UFH pump will not run but the boiler will re.
There are three other function switches as well. Pump & Boiler delay:This gives a three minute delay to allow actuators to open before the boiler res. Pump Only Delay: Delays only the UFH pump from ring for three minutes. Actuator NC or NO: This refers to Normally Open or Normally Closed. This should be set to NC for products.
2
Actuator Connections
Actuator connections corresponding to the thermostat connections. Up to 2 cables can be used in each connection (4 Actuators per Zone) If more, that number needs to be connected, then an external junction box will be needed. A maximum of xxx actuators can be connected to a zone in this manner.
Optional Cylinder Thermostat: If connecting the cylinder thermostat directly to the timer then a link needs to be tted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required. Optional Overheat Thermostat:Used for connecting a pipe thermostat to
prevent over temperature water damaging sensitive oors. Remove the link and connect the pipe thermostat so it is Normally Closed. The pipe stat will open if overheating occurs and the UFH pump will stop running. Optional Boiler Enable: This Volt Free connection must come from the boiler thermostat connection, when any zone calls for heat the Boiler enable will close causing the boiler to run. If work is being carried out on the boiler then power to and from the switch will cease. (Do not connect to the boiler IN terminal by linking a 230V feed from the wiring centre) Optional UFH Motorised Valve: If a UFH motorised valve is tted then remove the link between OR and GR. Optional Heat/Cool Changeover: This connection allows heat/cool changeover of all thermostats using a single external switch (installer supplied). Switch: Open-Heating Closed-Cooling
Motorised Valves, Pump, Boiler & Stat Connections
This must be carefully removed or replaced when removing or replacing the wiring centre cover, being careful to ensure the correct orientation.
Ribbon Connection
Thermostat Connections
Thermostat connections are to power the thermostats only, there is no switched live needed as this is done with a wireless signal. Power can therefore be supplied to the thermostat locally from any convenient power source if connecting to the wiring centre from the thermostat is dicult. Battery powered RF thermostats can also be used. These can be mixed with 230v RF thermostats or as an alternative.
A Coordinator will be
needed with all RF
products.
After setting up the coordinator will assign the wiring centre number. This is because more than 1 wiring centre may be used on a project. Pressing the network button will illuminate the relevant number. The example shown is for wiring centre 1, if 1 & 2 are lit it would be wiring centre 2.
3
4
5
9
6
8
1
Information Display
Thermostat Zones
Groups
1 2
NETWORK
BUTTON
7
www.salus-controls.com Technical Helpline 00000 000000
Option 2
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
link will be needed
between IN & OUT
as shown by arrow.
IN
HW CYLINDER THERMOSTAT
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT IN OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
ZONE 1 ZONE 2 ZONE 3 ZONE 4
SLNL SLNL SLNL SLNL SLNL
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
Sensor Terminals
Can be used for external AIR, Floor sensor when congured as thermostat. Can also be used for cylinder thermostat when connected for HW.
OPTONAL HOT WATER MOTORISED VALVE
OPTONAL UPH MOTORISED VALVE REMOVE LINK IF USED
Option 1
Connect Cylinder
Thermostat to
wiring centre
IN
HW CYLINDER THERMOSTAT
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
OUT IN OUT IN OUTBR EA N OR GR BR EA N OR GRLNE
ZONE 1 ZONE 2 ZONE 3 ZONE 4
SLNL SLNL SLNL SLNL SLNL
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
OPTONAL HOT WATER MOTORISED VALVE
OPTONAL UPH MOTORISED VALVE REMOVE LINK IF USED
Hot Water Connections
iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 2