Salus KL08RF Installation And Wiring Manual

Page 1
KL08RF
Installation and Wiring Guide
www.salus-controls.com Technical Helpline +44 (0) 1226 323 961
GROUP 2
GROUP CONTROL
THERMOSTAT
(MODEL VS10WRF)
BATTERY POWERED
PROGRAMMABLE ROOM THERMOSTAT (MODEL VS20WRF)
GROUP 1
THERMOSTAT
(VS20WRF)
GROUP 1
THERMOSTAT
(VS20WRF)
GROUP 1
THERMOSTAT
(VS10WRF)
GROUP 2
THERMOSTAT
(VS10WRF)
GROUP 2 CONTROL
THERMOSTAT
(VS20WRF)
GROUP 1
STANDALONE
PROGRAMMABLE
ROOM THERMOSTAT
(MODEL VS10W(MODEL VS20WRF
)
WRF)
SUPPLIED CABLES
230V TO UFH PUMP
UNDERFLOOR HEATING MANIFOLD
1.5MM2CABLE
(INSTALLER SUPPLIED)
Optional boiler connection
NL
External power supply
NL
These instructions apply to the SALUS model stated above.
Warning
This product must be tted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC mains supply before installing or working on any components that require 230 V AC 50Hz supply.
For PDF Installation guide go to www.salus-controls.com
Meets the following EC Directives
• Electro-Magntic Compatibility directive 2004 / 108 / EC
• Low-voltage Directive 2006/95/EC
Optional wireless
receiver RX10RF
Maintaining a policy of continued product development SALUS Controls plc reserves the right to change specication, design and materials of products listed on this installation guide without prior notice.
Issue Date: October 2014 Document Number 00106
Warning
The earth terminals on the KL08RF are for earth parking only. These terminals provide no earth protection.
iT600 Wiring Centre KL08RF 028 V9.qxp_Layout 1 04.12.2014 12:30 Strona 1
Page 2
Installation and Wiring Guide KL08RF
www.salus-controls.com Technical Helpline +44 (0) 1226 323 961
Installing and Connecting the KL08RF
Use the KL08RF wireless wiring centre to simply and safely connect thermostats and corresponding thermal actuators. The KL08RF connects to the wireless network through the CO10RF coordinator.One coordinator can support up to nine wiring centres, which means
that if you buy more than one wiring centre, you will only need one of the included coordinators. Keep the other coordinators in a safe place as spares.Install the KL08RF only
in dry and closed interior rooms. Relative air humidity in the room may not exceed 95%. Clean the KL08RF only with a dry and soft cloth. Do not use solvents or aggressive cleaning agents.
Remove the plastic
cover. Open (and close) the four white screws with a quarter turn only. Note that screws on opposite sides turn in the opposite direction.
2
Remove the white terminal connection board
3
Attach the back of the KL08RF to the DIN rail or wall.
4
Cut the power and device cable to length.
6
Push the power wires into the round power holes.
Attach the white
strain-relief using the two screws to secure the power wires.
8
Push the thermal actuator wires into the round holes at the bottom of the KL08RF. You can connect up to three actuators in each zone.
9
Push in the Pump wires at the bottom right of the KL08RF for volt-free pump switching.
10
Push in the Boiler wires at the bottom right of the KL08RF for volt-free boiler switching. When a zone calls for heat, the boiler switch closes causing the boiler to run.
11
Push in the CO wires at the bottom right of the KL08RF for volt-free heating/cooling changeover switching. An open switch is for heating (red LED). A closed switch is for cooling (blue LED).
12
Push in the Dew Point wires at the bottom right of the KL08RF for volt-free humidity sensing.
13
Attach the red strain-relieving strip using the three screws to secure the pump, boiler, CO, and dew point wires to the bottom side of the KL08RF.
14
Set the boiler delay, wireless, and thermal actuator jumpers at the top right of the KL08RF.
Jumper Settings/Positions for Pump/Boiler On/O Delay
The pump/boiler on delay and the pump o delay are xed at three minutes. The default setting for the boiler o delay is also three minutes, but can be changed to 15 minutes. To do this, carefully remove the jumper and re-insert it in the other position as shown below:
Wireless
The default setting for the wireless connection is internal (INT). To change this setting to external (EXT), carefully remove the jumper and re-insert it in the other position as shown below:
Type of Actuator
The default setting for the type of actuator is normally closed (NC). To change this setting to normally open (NO), carefully remove the jumper and re-insert it in the other position as shown below. Notethat the actuator setting and thermostat setting must be the same.
15
Make sure there is a fuse in the fuse holder.
LED indications
Name Colour Meaning
Power
KL08RF is supplied with 230V power
G1
Wireless network activity on group 1 thermostats
G2
Wireless network activity on group 2 thermostats
Network Status
KL08RF is waiting to pair
KL08RF is connected to the wireless network
Zone 1 actuators
Demand from group 1, zone 1 thermostat: actuator open
Zone 2 actuators
Demand from group 1, zone 2 thermostat: actuator open
Zone 3 actuators
Demand from group 1, zone 3 thermostat: actuator open
Zone 4 actuators
Demand from group 1, zone 4 thermostat: actuator open
Zone 5 actuators
Demand from group 2, zone 1 thermostat: actuator open
Zone 6 actuators
Demand from group 2, zone 2 thermostat: actuator open
Zone 7 actuators
Demand from group 2, zone 3 thermostat: actuator open
Zone 8 actuators
Demand from group 2, zone 4 thermostat: actuator open
Pump
Pump on
Boiler
Boiler on
CO
Heating mode
Cooling mode
16
Plug in the CO10RF coordinator.
Replace the plastic cover.
Switch on mains power supply to the unit. The red LED comes on.
Connecting the KL08RF(s) to the ZigBee Wireless Network
1. On powering up the KL08RF, all actuator LEDs light up green then go o, then the Network Status LED ashes green.
2. Press and hold the button on the coordinator for ve seconds. The button ashes red to indicate the coordinator is ready to pair. The Network Status LED on the KL08RF goes steady green when connected.
3. Repeat the process for every KL08RF in the system. Note that one coordinator can support up to nine KL08RFs.
4. To identify your KL08RF ( WC) number press Pair for one second. The LED on the zone number lights green: Zone 1 = WC -1, Zone 2 = WC ­ 2, and so on. The Network Status LED is used to identify WC-9.
5. To pair your VS10RF or VS20RF thermostats, see your thermostat manual.
6. Press the coordinator button for ve seconds until the LED shines steady red.
Note: To restore the KL08RF back to factory default settings at any time, using a suitable tool, press the Reset button to the right of the Pair button.
Checking the System Conguration and Communication
· Press and hold the coordinator button for one second. All devices connected to the system ash. To stop checking, press and hold the coordinator button again for one second.
· Press and hold the Pair button on the WC for ve seconds. All devices connected to the KL08RF ash. To stop checking, press and hold the Pair button again for ve seconds.
Deleting all Devices from the Wireless Network
· To delete all devices connected to the network, press and hold the coordinator button for 15 seconds. The colour of the button changes from red to amber.
· To delete all devices connected to the KL08RF, press and hold the Network Status button on the KL08RF for 15 seconds. The G1 and G2 LEDs turn from ashing red to solid red then go o. Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction manuals.
17
7
Device
Power/Thermostat
50mm
110mm
10mm
10mm
If you need to install the optional external antenna and have set the
Wireless jumpers to EXT:
a. Disconnect power.
b. Remove the protective cap from the antenna connection on the underside of the KL08RF.
c. Screw the antenna into the KL08RF.
d. Reconnect power. The KL08RF will now use the external antenna and not the internal antenna.
19
Heating mode
Cooling mode
5
Replace the
white terminal
connection board
1
18
iT600 Wiring Centre KL08RF 028 V9.qxp_Layout 1 04.12.2014 12:31 Strona 2
Loading...