Salus EP101 Instruction Manual

Page 1
Instruction Manual
Model No EP101
Programmable Heating Controller
2
Page 2
Page 3
PRODUCT COMPLIANCE
This product complies with the essential requirements of the following EC Directives:
Electro-Magnetic Compatibility directive 2004/108/EC
Low Voltage Directive 2006/95/EEC
EC Marking directive 93/68/EEC
SAFETY INFORMATION
These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model.
These instructions are intended to apply in the United Kingdom only, and should be followed along with any other statutory obligations.
This accessory must be fitted by a Competent person, and installation must comply with the guidance provided in the current editions of BS7671 (IEE Wiring Regulations) and Part ‘P’ of the Building Regulations. Failure to comply with the requirements of these publications could lead to prosecution.
Always isolate the AC Mains supply before opening or removing the unit from the wall or wall box.
When fitting batteries don’t mix old and new batteries together. Do not use rechargable batteries.
Please leave these instructions with the end user where they should be kept in a safe place for future reference.
EP101 INSTRUCTION MANUAL
3
Page 4
INTRODUCTION
A A programmable heating controller is used to switch the heating system in your home on and off as needed. It works by controlling the heating boiler according to a series of programmed settings that take effect at different times of the day.
The EP101 from Salus Controls is a stylish and accurate 5/2 or 7 day programmable heating controller with a large, easy to read Liquid Crystal Display (LCD). This controller has been specifically designed to be used for single channel Volt Free or 230V AC heating applications.
A simple jumper switch changes the EP101 between 5/2 or 7 day programming.
Features
Timed control of central heating
Large LCD with blue backlight
Stylish Casing
Volt Free Contacts
Built-in start up programme
12 or 24 hour clock display
Advance 1 hour facility
Holiday Function
5/2 or 7 day programming
Three On / Off periods
Memory backup
EP101 INSTRUCTION MANUAL
4
Page 5
INSTALLATION
Please read the important safety information at the start of this manual before you begin to install the device.
The ideal position to locate the EP101 programmable heating controller is about 1.5m above floor level. It should be mounted in a location where the controller is easily accessible, reasonably lit and free from extremes of temperature.
The electrical connections to the EP101 are made to the supplied industry standard backplate. This simplifies installation, as no connections are made to the controller itself. Connection details are shown below - no Earth connection is required for the correct and safe operation of the EP101, but a parking terminal is provided to connect an Earth wire if one is present.
230V AC Switching
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Hot Water Off
2 No Connection
3 Switched Live (output)
4 230V link from Mains Live
(do not remove)
Earth Parking
(no electrical connection)
EP101 INSTRUCTION MANUAL
5
Page 6
After installing the backplate in a suitable location, wiring connections can be made as shown above. The following criteria apply to the installation:
The incoming AC mains supply should be 230V AC and fused at 6 amps.
Optimum cable size for installation is 1.5 mm2; wiring colours should be in accordance with the current requirements of the IEE Wiring Regulations.
Cable entry should be from the rear of the backplate.
All wiring connections should be securely made, and be firmly gripped beneath the terminal square brass washer.
Do not restore the mains supply to the system until all associated items are fully installed.
NOTE: All electrical installation work should be carried out
by a suitably qualified Electrician or other competent person.
If you are not sure how to install this programmable thermostat consult either with a qualified electrician, heating engineer or your boiler / heating system supplier for advice on how to continue.
Do not remove or refit the EP101 onto the backplate without the mains supply to the system being isolated.
Volt Free Switching
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Normally Closed (NC)
2 No Connection
3 Normally Open (NO)
4 Volt Free Common
Earth Parking
(no electrical connection)
EP101 INSTRUCTION MANUAL
6
Page 7
JUMPER SETTINGS
Changes to the jumper settings should only be made by the Engineer carrying out the installation or other qualified person.
The installer should select the jumper positions required if changes need to be made to the factory default settings. These jumpers are found on the rear of the controller.
Jumper Function Default
Program Type Movable jumper for 5-2 or 7 5-2
individual days programming. programming
Internal Movable jumper for Internal backup Backup Battery enabling or disabling the battery disabled
internal backup battery.
The installer should enable the internal backup battery before fitting the controller to ensure user settings are retained – the battery will be kept charged from the controller mains supply.
EP101 INSTRUCTION MANUAL
7
Page 8
AFTER INSTALLATION
After completing installation and powering up the EP101 for the first time the controller will behave in the following way:
All the indicators on the display and the backlight will be turned on for two seconds. After two seconds, the EP101 will then operate in Normal mode (controller output OFF).
All the controller settings will be returned to default values. If the Reset Button is pressed, the EP101 will behave in the same way as described above, except that any previously saved user settings will be deleted and overwritten with the default settings.
EP101 INSTRUCTION MANUAL
8
Page 9
USER INTERFACE AND CONTROLS
The status and operation of the EP101 can be clearly seen on the large backlit Liquid Crystal Display (LCD) - this display allows the user to see at a glance the current status of the heating system.
There are few user controls for the EP101, making the controller very easy to operate. These controls are shown below, along with a description of each of their functions.
User Control Function Summary
Key / Operation Symbol Functions
+1Hr Temporary override
UP key Increases the selected setting
DOWN key Decreases the selected setting
BACKLIGHT / Manually turns on the LCD backlight HOLIDAY key for 5 seconds, or activates /
deactivates Holiday Override
MODE key Selects operating mode
SELECT key Selects a clock or programme setting
SET key Sets a clock or programme setting
RESET button Resets the controller to default
(original factory) settings
EP101 INSTRUCTION MANUAL
9
Page 10
OPERATION
The EP101 is configured and adjusted by the use of an intuitive user interface with a minimal number of user controls.
The backlit LCD gives a highly visible, easily readable indication of the controller status.
Setting the Time
Press and hold SET and SELECT when the EP101 is in Normal mode for three seconds to enter the Clock setting mode. Releasing both keys will display “12 hr” or “24 hr” and SET, as shown below:
Release the SET and SELECT keys and press UP or DOWN to toggle between 12 and 24 hour time format.
Pressing and releasing SELECT will then display the time and a SET indicator, with all other indicators cleared from the display. The hour part of the time will be flashing to indicate that it is the currently selected item and is ready to be adjusted.
Press the UP or DOWN keys to increase or decrease the hour setting – the selected item will stop flashing while a key is pressed, and will resume flashing when you release the key.
Press the SELECT key to select the ‘minutes’ section of the time. Set the minutes in the same way as the hour by using the UP and DOWN keys.
EP101 INSTRUCTION MANUAL
10
Salus EP101 Manual 001:89 21/11/10 11:49 Page 10
Page 11
Pressing and releasing SELECT again will then display the year as displayed
Press the UP or DOWN keys to increase or decrease the year – valid settings are between 05 and 99 (indicating a year range of 2005 to 2099).
Press the SELECT key to select the month section of the date – this is adjusted in the same way by using the UP and DOWN keys – valid settings are between 01 and 12
Press the UP or DOWN keys to then increase or decrease the day setting.
Pressing and releasing SELECT again will then take you to the final part of the time and date setting process: enabling daylight saving.
Press the UP or DOWN keys to enable or disable the daylight saving setting
Pressing the SET key will confirm and save the settings, before returning the EP101 to Normal mode. Not pressing any keys for more than 15 seconds will also update the clock settings and return the controller to Normal mode.
EP101 INSTRUCTION MANUAL
11
Salus EP101 Manual 001:89 21/11/10 11:49 Page 11
Page 12
PROGRAMMING THE EP101
The EP101 offers great versatility with its programming options, allowing the user to programme the unit to operate on a 5/2 or 7 day control cycle. The controller has a default set of programmes that have been designed to meet the needs of most users. If these default programmes are not suitable for your particular situation, reprogramming the EP101 with your own settings is a very straightforward operation.
Selection of the default programming mode (5/2 or 7 day) is made by changing the jumper setting on the rear of the controller, as previously described within the Installation section of this manual.
5/2 Day Mode
5/2 day mode is the default programming mode for the EP101. With this mode selected three different sets of on/off times can be set for Weekdays or Weekends.
To review or change a programme, press the SET key when the EP101 is in Normal mode. This will change the unit status to Programme Setting mode.
The display will show programme number 1 and SET PROG, with all other indicators cleared. The weekdays will be flashing to indicate they are the selected item and are ready to be adjusted:
Press the UP or DOWN key to select the programme set for either Weekday or Weekend to be reviewed or adjusted. Pressing the SET key at any time when in programming mode will return the EP101 into Normal mode.
EP101 INSTRUCTION MANUAL
12
Salus EP101 Manual 001:89 21/11/10 11:49 Page 12
Page 13
Press the SELECT key to confirm the Weekday or Weekend selection. Once this is set, the ‘Hour’ will flash to indicate that it is the selected item and is the next item to be adjusted:
Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key.
Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence:
Programme Status Function Sequence
1 ON Hour Minutes
1 OFF Hour Minutes
2 ON Hour Minutes
2 OFF Hour Minutes
3 ON Hour Minutes
3 ON Hour Minutes
…before then allowing you to cycle back to Programme 1. Pressing the SET key at any time will confirm the setting and return to the programme set selection.
EP101 INSTRUCTION MANUAL
13
Salus EP101 Manual 001:89 21/11/10 11:49 Page 13
Page 14
7 Day Mode
The EP101 also offers a 7 day programming mode, which allows you to programme three different sets of on/off times for each day of the week to give a total of 21 separate programme settings.
To review or change a programme, press the SET key when the EP101 is in Normal mode. This will change the unit status to Programme Setting mode.
The controller will display programme number 1 and SET PROG, with all other indicators cleared. The weekday will be flashing to indicate the selected item is ready to be adjusted.
Press the UP or DOWN key to change the display to indicate the single day you want to programme:
Pressing the SET key at any time when in programming mode will return the EP101 into Normal mode. Press the SELECT key to confirm the Day selection. Once this is set, the ‘Hour’ will flash to indicate that it is the selected item and is the next item to be adjusted:
Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key.
EP101 INSTRUCTION MANUAL
14
Salus EP101 Manual 001:89 21/11/10 11:49 Page 14
Page 15
Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence:
Programme Status Function Sequence
1 ON Hour Minutes
1 OFF Hour Minutes
2 ON Hour Minutes
2 OFF Hour Minutes
3 ON Hour Minutes
3 ON Hour Minutes
…before then allowing you to cycle back to programme 1. Pressing the SET key at any time will confirm the setting and return to the programme set selection. Each programme for all the other days of the week is set in exactly the same way – just repeat the steps shown above, after entering programming mode and selecting the day you want to programme.
Regardless of which programming mode the EP101 is set for (5/2 or 7 day), not pressing any keys for 15 seconds will automatically save any programming changes and exit to Normal mode. Programmes can be reviewed or changed even if temporary override mode is enabled.
Please be aware that each of the programme time settings must be in sequence: for example, the OFF time cannot be earlier than the ON time,
programme 3 cannot be set with a time earlier than Programme 2. If this situation occurs, then the EP101 may operate in an unpredictable way.
EP101 INSTRUCTION MANUAL
15
Salus EP101 Manual 001:89 21/11/10 11:49 Page 15
Page 16
OPERATING MODE SELECTION
The EP101 operating mode is selected by pressing the MODE key. There are four operating modes for the controller:
ON, ONCE, AUTO and OFF
The mode can be changed when the controller is in NORMAL mode by pressing the MODE key. Each key press will cycle the operation mode as follows:
ON ONCE AUTO OFF ON
The mode indicator changes to indicate the selected operating mode:
The operating mode functions are:
Mode Possible selections Function
ON ON Continuously on
ONCE ON, ONCE On for one period per day
(from Programme 1 ON to Programme 3 OFF)
AUTO ON, ONCE, AUTO Automatic programme control
OFF ON, ONCE, AUTO, OFF Continuously off
EP101 INSTRUCTION MANUAL
16
Salus EP101 Manual 001:89 21/11/10 11:49 Page 16
Page 17
Holiday Override Mode
The holiday override mode allows the user to override all the current programme settings and turn off the heating for up to 31 days. When the EP101 is in Normal mode, pressing the BACKLIGHT/HOLIDAY key for 3 seconds or longer allows you to turn on the holiday override mode. The controller display will have the day numeral flashing to indicate that it is ready to be adjusted, as shown in the image below:
Use the UP and DOWN keys to increase or decrease the number of days to turn the system off. The maximum number of allowable override days is 31 – increasing past this number will roll back the display to 0 and disable the holiday override mode.
Pressing the SET key, or not pressing any keys for more than three seconds will activate the holiday override mode and the heating will immediately be turned off. The EP101 display will change to show the number of days the system will be turned off for – the number of days displayed will decrease at midnight each day.
Cancelling Holiday Override Mode
Pressing the BACKLIGHT/HOLIDAY key for more than three seconds will turn off the holiday override mode and return the EP101 to Normal mode.
EP101 INSTRUCTION MANUAL
17
Salus EP101 Manual 001:89 21/11/10 11:49 Page 17
Page 18
Temporary Override Mode
The temporary override mode allows the user to override the current programme settings and turn the heating on for a preset period. This mode is activated by pressing the +1Hr key.
After pressing the +1Hr key, the controller display will change have the day numeral flashing to indicate that it is ready to be adjusted, as shown in the image below:
Each press of the +1Hr key will increase the duration of the override by one hour, to a maximum duration of nine hours. Increasing the setting beyond this level will roll the setting back to 0 and disable the temporary override.
Pressing the SET key, or not pressing any keys for more than three seconds will activate the temporary override mode and the heating will immediately be turned on. After 10 seconds, the EP101 display will change to a countdown display showing the amount of time the system will be turned on for. The MODE indicator will flash in the ON position for the duration of the temporary override.
The EP101 will go back to Normal mode at the end of the manual override period.
Cancelling Temporary Override Mode
To turn off the temporary override, press the +1Hr key until the display indicates 0. Pressing the SET key, or not pressing any keys for more than three seconds will then disable the temporary override mode.
EP101 INSTRUCTION MANUAL
18
Salus EP101 Manual 001:89 21/11/10 11:49 Page 18
Page 19
OTHER FUNCTIONS AND CONTROLS
Backlight
The backlight of the EP101 is switched on automatically whenever any of the keys are pressed. The backlight will remain illuminated for approximately 5 seconds after the last key press, except if you are changing settings within the Clock, Programme or Temporary Override modes – in this case the backlight will remain illuminated throughout the setting change process.
The backlight will not illuminate if there is no mains supply to the controller.
Daylight Saving
When enabled, the clock will automatically change from Greenwich Mean Time (GMT) to British Summer Time (BST) on the last Sunday in March at 2:00am. The clock will automatically change back to GMT on the last Sunday in October at 2:00am.
Reset Button
The Reset Button is provided as a way to restore the heating controller to its default factory settings. Pressing this button will delete any
previously entered settings.
EP101 INSTRUCTION MANUAL
19
Salus EP101 Manual 001:89 21/11/10 11:49 Page 19
Page 20
MAINTENANCE
The EP101 programmable heating controller requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat).
There are no user serviceable parts within the unit; any servicing or repairs should only be carried out by Salus Controls or their appointed agents.
Should the EP101 programmable heating controller fail to function correctly, check:
Mains supply to the EP101 is switched on.
Heating system is switched on.
If the EP101 is still not functioning correctly, press the Reset Button.
WARRANTY
Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
EP101 INSTRUCTION MANUAL
20
Salus EP101 Manual 001:89 21/11/10 11:49 Page 20
Page 21
PRODUCT SPECIFICATION
Model: EP101 Type: Programmable heating controller
designed for 230V AC and Volt Free heating applications.
Programming
Programming Modes: User selectable for 5/2 or 7 day option Number of Programmes: Three (3) user programmes plus
factory default programme.
Override Facility: User selectable programme
override facility.
Holiday Facility: User selectable option to temporarily
override selected programme.
Default Programmes
Programme Output Weekday Weekend
1 ON 6:00 AM 6:00 AM
OFF 8:00 AM 8:00 AM
2 ON 10:00 AM 10:00 AM
OFF 12:00 PM 12:00 PM
3 ON 6:00 PM 6:00 PM
OFF 10:00 PM 10:00 PM
Switching
Switching Voltage: 230V AC / 50Hz Switching Current: 16A resistive, 5A inductive Contact Type: Single Pole Double Throw (SPDT)
Environment
Operating Temperature: 0 ºC to + 50 ºC Storage Temperature: - 20 ºC to + 60 ºC
EP101 INSTRUCTION MANUAL
21
Salus EP101 Manual 001:89 21/11/10 11:49 Page 21
Page 22
Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
EP101 Warranty
Customer Name: ....................................................
Customer Address: ................................................
...............................................................................
Post Code: ..................... Tel No: ............................
Email: .....................................................................
Engineers Company: ..............................................
Tel No: ...................................................................
Email: ....................................................................
Intallation Date: .....................................................
Engineers Name: ....................................................
Engineers Signature: ..............................................
EP101 INSTRUCTION MANUAL
22
Salus EP101 Manual 001:89 21/11/10 11:49 Page 22
Page 23
Salus EP101 Manual 001:89 21/11/10 11:49 Page 23
Page 24
Email: sales@salus-tech.com Tel: 01226 323961 Email: tech@salus-tech.com Tel: 01226 323961
Sales
:
Technical
:
Salus Controls plc, Salus House, Dodworth Business Park South,
Whinby Road, Dodworth, Barnsley S75 3SP
salus-tech.
Salus EP101 Manual 001:89 21/11/10 11:49 Page 24
Loading...