Salus AHTR5024 Installer Manual

Page 1
INSTALLER MANUAL
Wired Digital Thermostat
Model: AHTR5024
Page 2
Contents of the box
Manual Contents:
Box Contents Introduction Product Compliance and Safety Information Installation User Interface Status/LED indication Installers notes Warranty
Icons used in this manual:
Safety
Important info
Your benefit
Fixing Screws 1 x Installer Manual
INSTALLER MANUAL
Wired Digital Thermostat
Model: AHTR5024
AHTR5024 Thermostat
2 AHTR5024 Instruction Manual
Page 3
Product Compliance and Safety Info
AHTR5024 Instruction Manual 3
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Page 4
4 AHTR5024 Instruction Manual
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003
du Canada.
Product Compliance and Safety Info Continued
Page 5
AHTR5024 Instruction Manual 5
Safety Information
Use in compliance with safety regulations. The unit is to be used for the control of room temperature inside the house.
Installation This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could
lead to prosecution.
Product Compliance and Safety Info Continued
Page 6
Product Description
Installing the unit
Thank you for purchasing the SALUS AHTR5024 Thermostat. This thermostat is a device that lets you customize the heating and cooling of your home as needed.
The AHTR5024 device from SALUS North America is a stylish and accurate digital room thermostat that is fitted with a large easy to read LCD screen and one touch buttons. You can now simply adjust your home temperature as desired in order to create a comfortable home environment.
We hope you enjoy our product.
Install the AHTR5024 digital room thermostat roughly about 1.5m above floor level. It should be mounted in a location where the thermostat is easily accessible and away from direct sunlight. You can mount the thermostat directly on the wall or you can install it on top of a wall-box.
6 AHTR5024 Instruction Manual
Page 7
1. Mounting the Thermostat
Gently remove front housing.
Without floor sensor With floor sensor
AHTR5024 Instruction Manual 7
Page 8
2. Terminal Connection
N
N
L
CO
L
N
S1
ACTUATOR
OPTIONAL EXTERNAL
PROBE
E.G.
HEAT
PUMP
OUTPUT
TO MULTIPLE
DEVICES
NSB
OUTPUT
230VAC
50Hz
N
CO
L
N
S1
Note: You can wire the thermostat directly to the AKL08 wiring centre or to an actuator (purchased separatly).
8 AHTR5024 Instruction Manual
24VAC
50Hz
H
H
H
H
N
CO
L
N
S1
H
N
CO
L
N
S1
H
N N
S1
H
N N
S1
H
N N
S1
SH
H
Page 9
3. Thermostat Icons
BOX means to select mode. e.g. means Hi temp is selected means the Hi temp is not selected.
Sunny: Hi comfortable temperature
Moon: Low comfortable temperature
Indicates AUTO ON or AUTO OFF
Frost Protection Indicator: Frost protection is active, not available in cooling mode.
Indicates that the Party Mode is active
Indicates that the Holiday Mode is ON.
Heat Mode indicator: Indicates heating is running
AHTR5024 Instruction Manual 9
Page 10
4. Thermostat Icons Continued
Programs number indicator.
Indicates the time.
Indicates the the day of the week
Temporary override indicator: The hand will appear until the next programs starting time.
Cool Mode indicator: The icon is flashing when cooling mode is active
Temperature indicator
• Display the room temperature
• Display the set temp
10 AHTR5024 Instruction Manual
Page 11
5. Button Functions
Mode selection. Long press to return home without saving.
OK key. Short press to confirm selection. Long press to save and return home. Long press to enter Temperature offset Heat/Cool.
Decrease or increase Setpoint Temperature.
OR
Note: LCD backlight is activated by pressing any key.
AHTR5024 Instruction Manual 11
Page 12
6. Setting Date and Time
When you first power up your device you will have to set up the date and time.
Press to confirm.
Press or to choose 12/24 hr then press to confirm.
3
1 2
4
12 AHTR5024 Instruction Manual
X.x
Page 13
6. Setting Date and Time
Set the hour by using or
Set the minutes by using or . Press to confirm.
5 6
Set the date using the or . Press to confirm.
7 8
Note: You can access the date and hour by long pressing . After that press and to confirm.
AHTR5024 Instruction Manual 13
16
Page 14
7. Setting Your Programs
You can customise your programs by long pressing when on the program screen.
3
2
4
1
Set the hour using or . Press to confirm. Repeat the procedure for setting the minutes.
Select the desired program or by pressing or . Press to confirm.
Note: If you want to select another Program Profile (from the available 5), please enter in Installer Mode, choose option d17 and after that select the desired program.
14 AHTR5024 Instruction Manual
Page 15
7. Setting Your Programs
You can select and customise any of the following programs:
Program Prole 1
5 days (Monday to Friday)
Program
Program
Time
Heat set
point
Cool set
point
1 6:00 Sunny Sunny
2 9:00 Moon Moon
3 16:00 Sunny Sunny
4 23:00 Moon Moon
5 --:-- --:-- --:--
6 --:-- --:-- --:--
2 days (Saturday to Sunday)
Program
Program
Time
Heat set
point
Cool set
point
1 7:00 Sunny Sunny
2 23:00 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
AHTR5024 Instruction Manual 15
Page 16
7. Setting Your Programs
Program Prole 2
5 days (Monday to Friday)
Program
Program
Time
Heat set
point
Cool set
point
1 6:00 Sunny Sunny
2 22:30 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
2 days (Saturday to Sunday)
Program
Program
Time
Heat set
point
Cool set
point
1 7:00 Sunny Sunny
2 23:00 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
16 AHTR5024 Instruction Manual
Page 17
7. Setting Your Programs
Program Prole 3
5 days (Monday to Friday)
Program
Program
Time
Heat set
point
Cool set
point
1 5:00 Sunny Sunny
2 8:00 Moon Moon
3 14:00 Sunny Sunny
4 22:00 Moon Moon
5 --:-- --:-- --:--
6 --:-- --:-- --:--
2 days (Saturday to Sunday)
Program
Program
Time
Heat set
point
Cool set
point
1 7:30 Sunny Sunny
2 22:30 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
AHTR5024 Instruction Manual 17
Page 18
7. Setting Your Programs
Program Prole 4
5 days (Monday to Friday)
Program
Program
Time
Heat set
point
Cool set
point
1 6:00 Sunny Sunny
2 9:00 Moon Moon
3 15:00 Sunny Sunny
4 22:30 Moon Moon
5 --:-- --:-- --:--
6 --:-- --:-- --:--
2 days (Saturday to Sunday)
Program
Program
Time
Heat set
point
Cool set
point
1 7:30 Sunny Sunny
2 23:00 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
18 AHTR5024 Instruction Manual
Page 19
7. Setting Your Programs
Program Prole 5
5 days (Monday to Friday)
Program
Program
Time
Heat set
point
Cool set
point
1 6:00 Sunny Sunny
2 10:00 Moon Moon
3 16:00 Sunny Sunny
4 23:00 Moon Moon
5 --:-- --:-- --:--
6 --:-- --:-- --:--
2 days (Saturday to Sunday)
Program
Program
Time
Heat set
point
Cool set
point
1 7:30 Sunny Sunny
2 23:30 Moon Moon
3 --:-- --:-- --:--
4 --:-- --:-- --:--
5 --:-- --:-- --:--
6 --:-- --:-- --:--
AHTR5024 Instruction Manual 19
Page 20
8. How to reset the thermostat
31 2
Press the indicated keys together for 3 seconds.
Select P47 if you want to reset to factory settings.
Press to confirm.
4 5
Press to confirm.
20 AHTR5024 Instruction Manual
Page 21
9. Installer Mode
Select P49 if you want to enter Installer Mode.
You have reached the Installer Mode. Select your option by using or . Press to confirm.
Press to confirm.
Press the indicated keys together for 3 seconds.
3
1 2
4
Note: This function allows you to customise your thermostat as you desire. In order to do this please consult the tables on the next pages.
AHTR5024 Instruction Manual 21
Page 22
10. Functions explained
d05
dxx
d01
d02
d07
d08
d03
d04
Heating Control
Room temp. oset
Valve Protection
Frost Setpoint
OUT sensor probe (S1/S2)
Air sensor or Floor sensor
Cooling Control
0
-3.0C to + 3.0C
0/1
5ºC - 17ºC
0
0
1 2
1
1
1 2
PWM (Pulse-width modulation)
Oset room temp measuring error (in 0.5ºC)
0 = VP disabled 1 = Enable
Out sensor probe not connected
A: if d03 = 0, IN sensor controls Tr
ON-OFF: 0.5ºC (± 0.25ºC)
F: if d03 = 0, IN sensor controls Tr
A: if d03 = 1, IN disabled and OUT controls Tr
ON-OFF: 1.0ºC (± 0.5ºC)
F: if d03 = 1, IN disabled and OUT controls Tr Floor Protection
Out sensor probe connected
ON-OFF: 0.5C (± 0.25ºC) ON-OFF: 1.0C (± 0.5ºC)
0
0.0ºC
1
5.0ºC
0
0
2
D setting function
Parameter/
Values
Default
value
Denition
22 AHTR5024 Instruction Manual
d00 Select C/F
0
1
Select C
Select F
0
Page 23
10. Functions explained
d09
d11
12/24 Hour Format
Daylight Saving Time
0
0
1
1
12hr
O
24hr
On
(DST)
1
1
d12 Maximum limitation of
heating setpoint
5ºC - 35ºC
35ºC
d13 Maximum limitation of
cooling setpoint
5ºC - 40ºC
5ºC
d14 Floor sensor protection limit
(heating high limit-HL)
11ºC - 45ºC
Turn o relay output when oor sensing temp >
27ºC
d15
d16
Floor sensor protection limit
Floor sensor protection limit
(heating low limit-LL)
(cooling)
6ºC - 40ºC
6ºC - 45ºC
Turn on relay output when oor sensing temp <
Turn o relay output when oor sensing temp <
10ºC
6ºC
protecting limit, step is 0.5ºC
protecting limit, step is 0.5ºC
protecting limit, step is 0.5ºC
AHTR5024 Instruction Manual 23
Page 24
10. Functions explained
d17
d18
d19
d20
Preset program selection
Heat/Cool Mode Selection
Cooling Blocked
Actuators loading selection for dierent temperature compensation.
1: x 1 actuator loading 2: x 2 actuators loading 3: x 3 actuators loading 4: x 4 actuators loading 5: x 5 actuators loading
1-5
0 or 1
0 or 1
1 to 5 1
0
0
0: No connection 1: Connection
1: Cooling disabled
0: Cooling allowed
Select one of these 5 default programs. Once selected, default program will overwrite present program. Selected default program can be edited by the user in the User Setting Mode.
1
11. Cooling Blocked
When When the thermostat is set on Cooling Disabled (d19-->1) it will block the cooling function for single rooms until the device will receive the heating command. During the periods of cooling blocked no special indicator will be displayed on the LCD screen. Ice flake will also be turned off.
Note: d19 will be available only if d18 is set on 1 (Heat/Cool Mode selection Connected).
24 AHTR5024 Instruction Manual
Page 25
The maximum time allowed on the Party Mode is 9 h 50 min and can be set from 0-10 min.
3
If you want to exit Party Mode, press or to move the (box) to a different program. Once Party Mode ends the countdown automatically resets to 0.
12. Party Mode
Press or to select Party Mode.
Press or to select the time for Party Mode.
1 2
AHTR5024 Instruction Manual 25
Page 26
13. Vacation Mode
14. Frost Mode
Press or to select Vacation Mode.
Press or to select the number of vacation days.
1 2
Note: Vacation Modes ends when it reaches day 0. After that the device goes back to Auto Mode.
1 2
Press or to select Frost Mode. Press to confirm.
Press or if you want to change the Frost Mode temp. Press to confirm.
26 AHTR5024 Instruction Manual
Page 27
15. Temperature Offset
31 2
Long press in order to enter Settings Mode.
Press to enter
Setting Mode.
Press or in order to
set the Temperature Offset.
4 5
The Temperature Offset can be set at any value
between -3ºC and +3ºC. Press to confirm.
AHTR5024 Instruction Manual 27
Page 28
Technical Specification
Model: AHTR5024
Voltage 24 VAC, +/-10%, 50/60 Hz
Operating performance 24 V, 18W
Temperature setback Adjustable
Temperature range 5°C – 35°C
Span +/- 0.5°C or +/- 0.25°C
Storage temperature -20°C to +60°C
Ambient temperature 0 °C up to 45 °C
Degree of protection IP 30
Conformity according to FCC and IC
Housing material PC, V2
Color RAL 9010 pure white
Connection Screw terminal
Weight 125 g net / 170 g gross
Puls-wide-modulation (PWM) Yes
Clock, Timer Yes, programmable
Profile Modes 3 ( Sun, Moon, Automatic)
Heating and Cooling Yes, automatically Change Over on the Wiring Centre
Parameter adjustment Yes, in Installer Mode Dimensions 85mm*85mm*25mm
28 AHTR5024 Instruction Manual
Page 29
Notes
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
..................................................................................................................................................................................
AHTR5024 Instruction Manual 29
Page 30
Notes
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
...................................................................................................................................................................................
..................................................................................................................................................................................
30 AHTR5024 Instruction Manual
Page 31
Warranty
Customer Name: ......................................................................................................................................
Customer Address: .................................................................................................................................
.............................................................................................................................................................................
....................................................................................... Post Code: ............................................................
Tel No: ................................................................ Email: .............................................................................
Engineers Company: .............................................................................................................................
Tel No: ................................................................ Email: .............................................................................
Instalation Date: .......................................................................................................................................
Engineers Name: ......................................................................................................................................
Engineers Signature: .............................................................................................................................
SALUS North America warrants that this product (AHTR5024) will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS North America sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
AHTR5024 Instruction Manual 31
Page 32
SALUS North America is a member of the Computime Group
Issue Date: Oct 2016 00188
For PDF Installation guide please go to www.salusna.com
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
www.salusna.com
SALUS NORTH AMERICA, 850 MAIN STREET, REDWOOD CITY, CA 94063
EMAIL: SALES@SALUSNA.COM TEL:
+1-650-360-1725
Loading...