Salter Housewares PS250 User Manual

Page 1
PS250 Platform Scale
8VHU,QVWUXFWLRQV
0DQXHOG·XWLOLVDWLRQ %HGLHQXQJVDQOHLWXQJ ,VWUX]LRQLSHUO·XWHQWH
MULTI-LINGUAL
76103-578 Issue 0 C 25.03.2002
Page 2
Page 3
The information contained herein is the property of Salter Brecknell Weighing and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
PS250 User Instructions
Page 4
Page 5
Contents
page no.
Declaration of Conformity Safety
Warnings 3 Safe installation 3 Safe use 3 Cleaning the machine 3 EMC compliance 4
1 About your machine
1.1 Description 5
1.2 Display 5
1.3 Key functions 5
1.4 Error codes 6
1.5 Specification 6
1.6 Power supply 7
2 Weighing
2.1 Hold function 10
3 Setup mode 
3.1 Function setup 12
3.2 Calibration 14
PS250 User Instructions i
Page 6
Page 7
Declaration of Conformity
Manufacturer Salter Brecknell Type PS250 corresponds to the requirements of the following EC directives: EMC Directive EMC 89/336/EEC Low Voltage Directive LVD 73/23/EEC
The applicable harmonised standards are:
A copy of the original signed declaration for this instrument is available from:
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE
EN60950, EN50081–1, EN50082–1
Page 8
Déclaration de Conformité
Fabricant Salter Brecknell Type PS250 Correspond aux exigences des directives CE suivantes: Directive CEM CEM 89/336/EEC Directive Basse Tension LVD 73/23/EEC
Les standards harmonis és applicables sont:
Une copie originale de la déclaration signée pour cet instrument est disponible à:
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE
EN60950, EN50081–1, EN50082–1
Page 9
Konformitätserklärung
Hersteller Salter Brecknel l Typ PS250 entspricht den Anforderungen der folgenden EU-Richtlinien: EMV-Richtlinie EMC 89/336/EEC Niederspannungsrichtlinie LVD 73/23/EEC
Die angewendeten harmonisierten Normen sind:
Eine Abschrift der original unterschriebenen Konformitätserklärung ist unter unten genannter Adresse erhältlich:
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE
EN60950, EN50081–1, EN50082–1
Page 10
Dichiarazione di conformità
Produttore Salter Brecknell Modello PS250 è conforme alle caratteristiche previste dalle seguenti direttive CE Normativa EMC 89/336/CE Normativa per la bassa tensione 73/23/CE
Le norme standard armonizzate applicate sono:
Se richiest o, è disponibile una copia delloriginale certificato firmato da:
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE
EN60950, EN50081–1, EN50082–1
Page 11
Electromagnetic Compatibility Statement for North America
This equipment has b een te sted a nd foun d t o comply with th e lim its for a Class A digital device, pursuant to Part 15 of the FCC Ru les. These limi ts are desig ned to provide reasonable protection against harmf ul interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual , may cause harmful interfe rence to radio communica tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
-
PS250 User Instructions
1
Page 12
Page 13
Safety
Warnings Safe installation
Take care when lifting and transporting heavy objects.
Do not overload the machine. Take care not to exceed the weighing capacity of the machine.
Pluggable equipment must be installed near an easily accessible socket outlet. Permanently connected equipment must have a readily accessible disconnect device incorporated in the fixed wiring.
For your protection all mains (110V or 230V) equipment used out of doors or in wet or damp conditions should be supplied from a correctly fused source and protected by an approved RCD to BS7071 or BS7288 or BS4293.
The mains lead must be connected to a supply outlet with a protective earth contact. The electrical supply at the socket outlet must provide overcurrent protection of an appropriate rating.
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.
Safe use
To avoid the possibility of electric shock or damage to the machine, always switch off the machine and isolate from the power supply before carrying out any routine maintenance.
Cleaning the machine
CAUTION: Harsh abrasives, solvents, scouring cleaners and
alkaline cleaning solutions, such as washing soda, should not be used especially on the display windows. Under no circumstances should you attempt to wipe the inside of the machine.
PS250 User Instructions 3
Page 14
The outside of standard products may be wiped down with a clean cloth moistened with water containing a small amount of washing up liquid or disinfectant
EMC compliance
The following warning may be applicable to your machine.
WARNING:This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
4 PS250 User Instructions
Page 15
1 About your machine
1.1 Description
The PS250 is a self contained portable platfo rm scal e with a remote display. The platform is constructe d of mil d stee l; it has four adjustable feet for levelling and a non-slip mat for the platform. A bracket and fixings are supplied for des k or wall mounting the indicator head. For best resul ts, al ways ins tall the platform on a hard, flat, level surface.
A stainless steel platform vers ion i s availa ble.
1.2 Display
Net
0
888888.8
Low
kg lb oz
1 About your machine
SALTER
Brecknell
ON-OFF
ZERO
UNITS
HOLD
kg/x
0èç
TARE
T
250kg x 0.1kg/550lb x 0.2lb
Stable Net weight
net
PS250
Minus Hold weight
Low
0
Centre of zero weighing mode Low battery weighing mode
lb kg
1.3 Key functions
ZERO
0èç
TARE
PS250 User Instructions 5
Zero/ON/OFF key. Switches the scale on or off.
T
Tare key. Applies a tare value
Page 16
1 About your machine
UNITS
kg/x
Units key Selects weighing units
HOLD
Hold key Retains average weight display.
1.4 Error codes
Err Overload ErrL Below zero ErrE EEprom error
Low
Low battery warning
1.5 Specification
Capacity/resolution 250kg x 0.1kg
Display Height 25mm
Operating temperature Weight 22kg
Dimensions Platform 900mm x 550mm x 50mm Display head 270mm x 90mm x 45mm Power supply 6 x 1.2V metal hydride
Recharge adaptor 1 x 100V-240V AC/13V DC
550lb x 0.2lb
7 segment LCD 5º C to 35º C
rechargeable batteries
6 PS250 User Instructions
Page 17
1.6 Power supply
The indicator head contains six metal hydride re-chargeable batteries. The low battery indicator
battery power is insufficient to power the scale.
Recharging the batteries
Insert the AC re-charger adapter into the socket on the indicator head to recharge the batteries.
1 About your machine
is displayed when the
Low
Recharging time is approximately 14 hour s. Fully charged batteries should give approximately eight hours
of continuous use. CAUTION: Always connect the AC adaptor to the indicator
head before connecting to the mains power supply. Disconnect from the mains power supply before disconnecting
the adaptor from the indicator head.
AC adaptor
The 100V/240V recharge adaptor supplied with the P S250 i s provided with four convertion connectors:
2 pin European 3 pin UK 2 pin USA 2 pin Australia
PS250 User Instructions 7
Page 18
2 Weighing
ZERO
0èç
ZERO
0èç
2 Weighing
For best results, always weigh on a hard flat and level surface. The platform has four adjustable feet for level lin g.
ZERO
Press to switch on the scale. The display will show
then go to weighing mode. If the display does not show
 or press .
To switch off the scale, press and hold .
1. If necesssary, zero the scale.
0èç
ZERO
0èç
ZERO
0èç
0
0.0
kg
2.
15.3
kg
Using tares
3.
0
0.0
8 PS250 User Instructions
kg
Page 19
TARE
T
4.
ZERO
0èç
2 Weighing
5.
6. To cancel a tare
net
net
net
5.1
kg
kg
kg
kg
15.3
0
0.0
15.3
0
0.0
Weighing un i t s
UNITS
Press to toggle between kg, lb and oz.
PS250 User Instructions 9
kg/x
kg
Page 20
2 Weighing
HOLD
2.1 Hold function
This function enables you to weigh oversized objects that may obscure the display. The system calculates an average weight reading and displays this weight v alue. T his mak es the hold function ideal for weighing anim a ls that may be moving around on the platform.
1.
0
0.0
2.
0
0.0
3.
16.3
When the annunciator stops flashi ng, the weight is displayed and remains even when the load is remov ed.
16.3
kg
kg
kg
kg
10 PS250 User Instructions
Page 21
4. To cancel the hold:
HOLD
2 Weighing
0
0.0
kg
PS250 User Instructions 11
Page 22
3 Setup mode
3 Setup mode
3.1 Function setup
In setup mode you can configure the foll owing fu nctio ns:
weighing unit
auto shut-off
calibration weight
Auto shut-off switches off the scale if no ac tivi ty is se nsed during the period set. The time values are in sec onds. T o
disable auto shut-off, select Calibration weight allows you to sel ect ful l load, 0.5 load or
0.25 load of the machine capacity for calibra tion. The tabl e lists the actual weight value you should use.
2)).
Weighing units
kg 200 kg 100 kg 50 kg lb 500 lb 200 lb 100 lb
Full load
Calibration weights
1
/2 load
1
/4 load
12 PS250 User Instructions
Page 23
Set
TARE
T
UNITS
kg/x
3 Setup mode
Unit
A.OFF
CAP
CAL

divS GrAv
)XOO 
120 180 240 300 OFF
kg
lb
OFF
oz
OFFOFFON ON ON
Setup menu
Navigating the setup menu
1. Press and hold until display shows 6(7
TARE
T
(approximately three seconds).
2. Release , display shows 81,7.
3. Press to move across to the option or value you require.
End
4. Press to select an option and save.
HOLD
To exit the setup menu and save your changes :
Press until you see End.
Press to save your chang es and return to wei ghing
UNITS
kg/x
HOLD
mode.
PS250 User Instructions 13
Page 24
3 Setup mode
ZERO
0èç
UNITS
kg/x
3.2 Calibration
1. In setup mode, select &$/and then select whether you you want to use
Calibration weightson page 12). The example shown in these instructions uses kg weight units and your selection and then switch off the scale.
1. Hold
At the same time
1
/2, full or 1/4 load for calibration (see
1
/2 load. Save
x 3
4076
lb
Display shows zero cou n t val ue.
2.
TARE
T
0
0
14 PS250 User Instructions
lb
Page 25
3.
UNITS
kg/x
TARE
T
to select alternate units
4.
3 Setup mode
0
lb
0
0
kg
0
5.
100kg
7978
cal
100.0
kg
kg lb oz
kg
PS250 User Instructions 15
Page 26
Page 27
Page 28
Email: sales@salterbrecknell.co.uk
Email: sales@salterbrecknell.com
P.O. Box 9533, Smethwick,
Tel UK: 0870 444 6132 Fax UK: 0870 010 2241
3620 Central Avenue NE, Minneapolis,
Tel: 612 781 4211 Fax: 612 781 4320
West Midlands, B66 2TE
Salter Brecknell Weighing,
MN 55418, USA.
Loading...