The information contained herein is the property of Salter
Brecknell Weighing and is supplied without liability for errors or
omissions. No part may be reproduced or used except as
authorised by contract or other written permission. The
copyright and the foregoing restriction on reproduction and use
extend to all media in which the information may be embodied.
PS250 User Instructions
Page 4
Page 5
Contents
page no.
Declaration of Conformity
Safety
Warnings 3
Safe installation 3
Safe use 3
Cleaning the machine 3
EMC compliance 4
1About your machine
1.1Description5
1.2Display5
1.3Key functions5
1.4Error codes6
1.5Specification6
1.6Power supply7
2Weighing
2.1Hold function10
3Setup mode
3.1Function setup12
3.2Calibration14
PS250 User Instructionsi
Page 6
Page 7
Declaration of Conformity
ManufacturerSalter Brecknell
TypePS250
corresponds to the requirements of the following EC directives:
EMC Directive EMC 89/336/EEC
Low Voltage Directive LVD 73/23/EEC
The applicable harmonised
standards are:
A copy of the original signed declaration for this instrument is available
from:
FabricantSalter Brecknell
TypePS250
Correspond aux exigences des directives CE suivantes:
Directive CEM CEM 89/336/EEC
Directive Basse Tension LVD 73/23/EEC
Les standards harmonis és
applicables sont:
Une copie originale de la déclaration signée pour cet instrument est
disponible à:
HerstellerSalter Brecknel l
TypPS250
entspricht den Anforderungen der folgenden EU-Richtlinien:
EMV-Richtlinie EMC 89/336/EEC
Niederspannungsrichtlinie LVD 73/23/EEC
Die angewendeten
harmonisierten Normen sind:
Eine Abschrift der original unterschriebenen Konformitätserklärung ist
unter unten genannter Adresse erhältlich:
ProduttoreSalter Brecknell
ModelloPS250
è conforme alle caratteristiche previste dalle seguenti direttive CE
Normativa EMC 89/336/CE
Normativa per la bassa tensione 73/23/CE
Le norme standard armonizzate
applicate sono:
Se richiest o, è disponibile una copia dell’originale certificato firmato da:
Electromagnetic Compatibility Statement for North America
This equipment has b een te sted a nd foun d t o comply with th e lim its for a Class A
digital device, pursuant to Part 15 of the FCC Ru les. These limi ts are desig ned to
provide reasonable protection against harmf ul interference when the equipment is
operated in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and if not installed and used in accordance with
the instructions manual , may cause harmful interfe rence to radio communica tions.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his/her own expense.
-
PS250 User Instructions
1
Page 12
Page 13
Safety
Warnings
Safe installation
Take care when lifting and transporting heavy objects.
Do not overload the machine. Take care not to exceed the
weighing capacity of the machine.
Pluggable equipment must be installed near an easily
accessible socket outlet. Permanently connected equipment
must have a readily accessible disconnect device incorporated
in the fixed wiring.
For your protection all mains (110V or 230V) equipment used
out of doors or in wet or damp conditions should be supplied
from a correctly fused source and protected by an approved
RCD to BS7071 or BS7288 or BS4293.
The mains lead must be connected to a supply outlet with a
protective earth contact. The electrical supply at the socket
outlet must provide overcurrent protection of an appropriate
rating.
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED
ELECTRICIAN.
Safe use
To avoid the possibility of electric shock or damage to the
machine, always switch off the machine and isolate from the
power supply before carrying out any routine maintenance.
Cleaning the machine
CAUTION: Harsh abrasives, solvents, scouring cleaners and
alkaline cleaning solutions, such as washing soda, should not
be used especially on the display windows. Under no
circumstances should you attempt to wipe the inside of the
machine.
PS250 User Instructions3
Page 14
The outside of standard products may be wiped down with a
clean cloth moistened with water containing a small amount of
washing up liquid or disinfectant
EMC compliance
The following warning may be applicable to your machine.
WARNING:This is a class A product. In a domestic environment
this product may cause radio interference in which case the
user may be required to take adequate measures.
4PS250 User Instructions
Page 15
1About your machine
1.1Description
The PS250 is a self contained portable platfo rm scal e with a
remote display. The platform is constructe d of mil d stee l; it
has four adjustable feet for levelling and a non-slip mat for the
platform. A bracket and fixings are supplied for des k or wall
mounting the indicator head. For best resul ts, al ways ins tall
the platform on a hard, flat, level surface.
A stainless steel platform vers ion i s availa ble.
1.2Display
Net
0
888888.8
Low
kg
lb oz
1 About your machine
SALTER
Brecknell
ON-OFF
ZERO
UNITS
HOLD
kg/x
0èç
TARE
T
250kg x 0.1kg/550lb x 0.2lb
Stable Net weight
net
PS250
MinusHold weight
Low
0
Centre of zeroweighing mode
Low batteryweighing mode
lb
kg
1.3Key functions
ZERO
0èç
TARE
PS250 User Instructions5
Zero/ON/OFF key. Switches the scale on or off.
T
Tare key.Applies a tare value
Page 16
1 About your machine
UNITS
kg/x
Units keySelects weighing units
HOLD
Hold keyRetains average weight display.
1.4Error codes
ErrOverload
ErrLBelow zero
ErrEEEprom error
Low
Low battery warning
1.5Specification
Capacity/resolution250kg x 0.1kg
DisplayHeight 25mm
Operating temperature
Weight22kg
Dimensions
Platform900mm x 550mm x 50mm
Display head270mm x 90mm x 45mm
Power supply6 x 1.2V metal hydride
Recharge adaptor1 x 100V-240V AC/13V DC
550lb x 0.2lb
7 segment LCD
5º C to 35º C
rechargeable batteries
6PS250 User Instructions
Page 17
1.6Power supply
The indicator head contains six metal hydride re-chargeable
batteries. The low battery indicator
battery power is insufficient to power the scale.
Recharging the batteries
Insert the AC re-charger adapter into the socket on the
indicator head to recharge the batteries.
1 About your machine
is displayed when the
Low
Recharging time is approximately 14 hour s.
Fully charged batteries should give approximately eight hours
of continuous use.
CAUTION: Always connect the AC adaptor to the indicator
head before connecting to the mains power supply.
Disconnect from the mains power supply before disconnecting
the adaptor from the indicator head.
AC adaptor
The 100V/240V recharge adaptor supplied with the P S250 i s
provided with four convertion connectors:
2 pin European
3 pin UK
2 pin USA
2 pin Australia
PS250 User Instructions7
Page 18
2 Weighing
ZERO
0èç
ZERO
0èç
2Weighing
For best results, always weigh on a hard flat and level surface.
The platform has four adjustable feet for level lin g.
ZERO
Press to switch on the scale. The display will show
then go to weighing mode. If the display does not show
or press .
To switch off the scale, press and hold .
1. If necesssary, zero the scale.
0èç
ZERO
0èç
ZERO
0èç
0
0.0
kg
2.
15.3
kg
Using tares
3.
0
0.0
8PS250 User Instructions
kg
Page 19
TARE
T
4.
ZERO
0èç
2 Weighing
5.
6. To cancel a tare
net
net
net
5.1
kg
kg
kg
kg
15.3
0
0.0
15.3
0
0.0
Weighing un i t s
UNITS
Press to toggle between kg, lb and oz.
PS250 User Instructions9
kg/x
kg
Page 20
2 Weighing
HOLD
2.1Hold function
This function enables you to weigh oversized objects that may
obscure the display. The system calculates an average
weight reading and displays this weight v alue. T his mak es
the hold function ideal for weighing anim a ls that may be
moving around on the platform.
1.
0
0.0
2.
0
0.0
3.
16.3
When the annunciator stops flashi ng, the weight is
displayed and remains even when the load is remov ed.
16.3
kg
kg
kg
kg
10PS250 User Instructions
Page 21
4. To cancel the hold:
HOLD
2 Weighing
0
0.0
kg
PS250 User Instructions11
Page 22
3 Setup mode
3Setup mode
3.1Function setup
In setup mode you can configure the foll owing fu nctio ns:
•weighing unit
•auto shut-off
•calibration weight
Auto shut-off switches off the scale if no ac tivi ty is se nsed
during the period set. The time values are in sec onds. T o
disable auto shut-off, select
Calibration weight allows you to sel ect ful l load, 0.5 load or
0.25 load of the machine capacity for calibra tion. The tabl e
lists the actual weight value you should use.
2)).
Weighing
units
kg200 kg100 kg50 kg
lb500 lb200 lb100 lb
Full load
Calibration weights
1
/2 load
1
/4 load
12PS250 User Instructions
Page 23
Set
TARE
T
UNITS
kg/x
3 Setup mode
Unit
A.OFF
CAP
CAL
divSGrAv
)XOO
120180240300OFF
kg
lb
OFF
oz
OFFOFFONONON
Setup menu
Navigating the setup menu
1. Press and hold until display shows 6(7
TARE
T
(approximately three seconds).
2. Release , display shows 81,7.
3. Press to move across to the option or value you
require.
End
4. Press to select an option and save.
HOLD
To exit the setup menu and save your changes :
Press until you see End.
Press to save your chang es and return to wei ghing
UNITS
kg/x
HOLD
mode.
PS250 User Instructions13
Page 24
3 Setup mode
ZERO
0èç
UNITS
kg/x
3.2Calibration
1. In setup mode, select &$/and then select whether you you
want to use
’Calibration weights’on page 12). The example shown in
these instructions uses kg weight units and
your selection and then switch off the scale.
1.
Hold
At the same time
1
/2, full or 1/4 load for calibration (see
1
/2 load. Save
x 3
4076
lb
Display shows zero cou n t val ue.
2.
TARE
T
0
0
14PS250 User Instructions
lb
Page 25
3.
UNITS
kg/x
TARE
T
to select alternate units
4.
3 Setup mode
0
lb
0
0
kg
0
5.
100kg
7978
cal
100.0
kg
kg
lb oz
kg
PS250 User Instructions15
Page 26
Page 27
Page 28
Email:sales@salterbrecknell.co.uk
Email:sales@salterbrecknell.com
P.O. Box 9533, Smethwick,
Tel UK: 0870 444 6132 Fax UK: 0870 010 2241
3620 Central Avenue NE, Minneapolis,
Tel: 612 781 4211 Fax: 612 781 4320
West Midlands, B66 2TE
Salter Brecknell Weighing,
MN 55418, USA.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.