SaltDogg LS7 User Manual

9049 Tyler Blvd. • Mentor, Ohio 44060
TM
Phone (440) 974-8888 • Fax (440) 974-0165
Toll-Free Fax 800-841-8003 • saltdogg.com
Installation & Operator’s Manual
LS7 Liquid Spray System for SCH Style Spreaders
Installation Instructions
2. Position 30 gal. Tank (#3014062) on support as show in Fig.2
3. Attach Enclosure Assembly (#LS102) to Enclosure Bracket using provided hardware as show in Fig.2.
4. Secure Tank on Support using 2 locators (#3014080) and provided hardware as shown in Fig.3.
5. Plumb: reservoir, ball valve, filter, pump enclose and spray nozzle according to plumbing schematic using supplied fittings, hose and hose clamps. Do not use Teflon tape on threads. Use liquid thread sealant. (see fig.4, 5, 6 & 7).
—continued inside
1
9049 Tyler Blvd. • Mentor, Ohio 44060
TM
Phone (440) 974-8888 • Fax (440) 974-0165
Toll-Free Fax 800-841-8003 • saltdogg.com
3014084
3014077
3.38
Fig. 1
3014062
Fig. 2
LS102
2
9049 Tyler Blvd. • Mentor, Ohio 44060
TM
Phone (440) 974-8888 • Fax (440) 974-0165
Toll-Free Fax 800-841-8003 • saltdogg.com
Cab Controller Installation Instructions (Fig. 4)
1. Install cab controller (#WSE1) in cab for convenient driver operation. Mounting bracket and fasteners included.
2.
Route 8' wire harness (#WSE24) under dash from
controller (#WSE1) to truck’s fuse panel.
3. Ground “black” wire from controller to truck frame or truck’s battery (not dash).
4. Attach “green” wire in 8' wire harness (#WSE24) to a fused and keyed 15 Amp hot wire circuit.
5. Connect main power “white” wire in 8' wire har­ness (#WSE24) to fuse box that is “hot” full time or to battery “positive”.
6. Route the 25' wire harness (#WSE25) from the rear of the spreader to the cab. Plug connector on controller (#WSE1) to the connector on pump harness (#WSE25).
Fig. 3
3014080
Fig. 4 WSE1 Cab Controller front view
WSE25
25' Cable Connector
Connector
WSE24
8' Cable
Fig. 4 WSE1 Cab Controller back view
3
Loading...