Salsbury Recessed Mounted 4C Horizontal Mailbox ADA Accessibility Guidelines
Note: All units are shown mounted as low as the USPS mounting height requirements permit to maximize the number of compartments (indicated in the shaded areas) that fall below the ADA
upper reach limit of 48”. Consult with local authorities for specific standards.
(Revised 02/10/2017)
MAXIMUM HEIGHT UNITS
72"
60"
48"
36"
24"
12"
72"
60"
48"
36"
24"
12"
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
(9 MB1, 1 PL4.5, OM2) (3 MB2 , 1 MB3, 1 PL4.5, OM2) (1 PL4.5, 1 PL5, 1 PL6) (2 Receptacle Bins)(3 MB3, 1 PL4.5, OM2) (1 Collection Box)
ADA compliant compartment
3716D-20
(20 MB1, 2 PL4.5, OM2)
3716S-09 3716S-04 3716S-3P
3716D-19 3716D-09 3716D-8P3716D-07 3716D-6P
(19 MB1, 2 PL4.5, OM3) (7 MB2, 2 MB3, 2 PL4.5, OM2) (4 PL3, 1 PL4, 2 PL4.5, 1 PL5, CA)(1 MB2, 6 MB3, 2 PL4.5, OM2) (1 PL4, 2 PL4.5, 1 PL5, 2 PL6, CA)
3716S-03
3716S-2B
1
3716S-1C
1
15 DOOR HIGH UNITS
72"
60"
48"
36"
24"
12"
1 –
Note: These units do not meet U.S.P.S. installation requirements and
are for private delivery only unless approved by local postal authorities.
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
2
3715D-20
(20 MB1, 2 PL4, OM2) (18 MB1, 2 PL5, OM2)
(19 MB1, 1 PL4, 1 PL5, OM2) (15 MB1, 2 PL6, OM3)(17 MB1, 1 PL5, 1PL6, OM2)
ADA compliant compartment
3715D-19
2 –
For private delivery, unless parcel locker ratio exceeds requirement. U.S.P.S. standard 4C requires a minimum of one parcel locker for every ten (10) tenant compartments.
Parcel lockers must be a minimum of 15” high (PL4.5, PL5 and PL6) to meet the 1:10 ratio. Once this ratio has been met, smaller parcel lockers (PL3 and PL4) may also be added.
3715D-18
(16 MB1, 2 PL6, OM2) (9 MB2, 2 PL5, OM2)
3715D-153715D-17 3715D-16 3715D-09
(9 MB1, 1 PL4, OM2)
3 –
AFF=Above Finished Floor.
3715S-09
3715S-08
(8 MB1, 1 PL5, OM2)
Copyright © 2015 Salsbury Industries.
All rights reserved.
3715S-07
(7 MB1, 1 PL6, OM2)
Page 1 of 7
Salsbury Recessed Mounted 4C Horizontal Mailbox ADA Accessibility Guidelines
Note: All units are shown mounted as low as the USPS mounting height requirements permit to maximize the number of compartments (indicated in the shaded areas) that fall below the ADA
upper reach limit of 48”. Consult with local authorities for specific standards.
(Revised 02/10/2017)
15 DOOR HIGH UNITS (cont.)
72"
60"
48"
36"
24"
12"
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
(6 MB1,1 PL6, OM3)
14 DOOR HIGH UNITS
72"
60"
48"
36"
24"
12"
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
ADA compliant compartment
3715S-06
3715S-04
(4 MB2, 1 PL5, OM2)
3715S-3P
(3 PL5)
3715D-29
1
(28 MB1, OM2)(29 MB1, CA) (11 MB2, 2 MB3, OM2)
3715D-28
1
ADA compliant compartment
3714D-16 3714D-15 3714D-14 3714D-07
(16 MB1, 2 PL5, OM2)
(15 MB1, 1 PL5, 1 PL6, OM2) (14 MB1, 2 PL6, OM2) (7 MB2, 2 PL6, OM2)
3715D-13
(7 MB1, 1 PL5, OM2)
1
3714S-07
3715S-14
(3 MB2, 1 PL6, OM2)
1
3714S-03
3715S-13
(13 MB1, OM2)(14 MB1, CA)
1
(2 Receptacle Bins)
3714S-3P
(1 PL4, 2 PL5)
3715S-2B
1
1
3715S-1C
(1 Collection Box)
3714S-2P
(2 PL6, OM2)
72"
67" AFF
3
60"
48" AFF
3
48"
36"
3
28" AFF
24"
3
15" AFF
12"
Finished Floor
1 –
Note: These units do not meet U.S.P.S. installation requirements and
are for private delivery only unless approved by local postal authorities.
1
3714D-26
(26 MB1, OM2) (13 MB2, OM2)
2 –
For private delivery, unless parcel locker ratio exceeds requirement. U.S.P.S. standard 4C requires a minimum of one parcel locker for every ten (10) tenant compartments.
Parcel lockers must be a minimum of 15” high (PL4.5, PL5 and PL6) to meet the 1:10 ratio. Once this ratio has been met, smaller parcel lockers (PL3 and PL4) may also be added.
3714D-13
1
(12 MB1, OM2) (2 Receptacle Bins)(6 MB2, OM2) (1 Collection Box)
3714S-12
1
3714S-06
1
3714S-2B
3 –
AFF=Above Finished Floor.
1
1
3714S-1C
Copyright © 2015 Salsbury Industries.
All rights reserved.
Page 2 of 7
Salsbury Recessed Mounted 4C Horizontal Mailbox ADA Accessibility Guidelines
Note: All units are shown mounted as low as the USPS mounting height requirements permit to maximize the number of compartments (indicated in the shaded areas) that fall below the ADA
upper reach limit of 48”. Consult with local authorities for specific standards.
(Revised 02/10/2017)
13 DOOR HIGH UNITS
72"
60"
48"
36"
24"
12"
72"
60"
48"
36"
24"
12"
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
3713D-16
ADA compliant compartment
2
3713S-03 3713S-2P
(3 MB2, 1 PL5, OM2) (2 PL6, CA) (1 Receptacle Bin) (1 Collection Box)(11 MB1, OM2)
3713D-15
(14 MB1, 2 PL5, OM2)(16 MB1, 2 PL4, OM2)
3713D-14
1
3713D-24
(24 MB1, OM2)
3713D-13
(13 MB1, 1 PL5, 1 PL6, OM2)(15 MB1, 1 PL4, 1 PL5, OM2) (12 MB1, 2 PL6, OM2) (7 MB2, 2 PL5, OM2)
3713D-11
(9 MB2, 2 MB3, OM2)
3713D-12
1
3713S-11
3713D-07
1
3713S-1B
1
3713S-06
(6 MB1, 1 PL5, OM2)
3713S-1C
3713S-05
(5 MB1, 1 PL6, OM2)
1
12 DOOR HIGH UNITS
72"
60"
48"
36"
24"
12"
1 –
Note: These units do not meet U.S.P.S. installation requirements and
are for private delivery only unless approved by local postal authorities.
3
67" AFF
3
48" AFF
3
28" AFF
3
15" AFF
Finished Floor
(12 MB1, 2 PL5, OM2) (10 MB1, 2 PL6, OM2) (5 MB2, 2 PL6, OM2) (4 PL6) (22 MB1, OM2) (10 MB1, OM2)(2 MB2, 1 PL6, OM2) (2 PL6) (1 Receptacle Bin) (1 Collection Box)(11 MB1, 1 PL5, 1 PL6, OM2)
ADA compliant compartment
3712D-113712D-12 3712D-10 3712D-05 3712D-4P 3712S-02 3712S-2P
2 –
For private delivery, unless parcel locker ratio exceeds requirement. U.S.P.S. standard 4C requires a minimum of one parcel locker for every ten (10) tenant compartments.
Parcel lockers must be a minimum of 15” high (PL4.5, PL5 and PL6) to meet the 1:10 ratio. Once this ratio has been met, smaller parcel lockers (PL3 and PL4) may also be added.
3712D-22
3 –
AFF=Above Finished Floor.
1
1
3712S-10
Copyright © 2015 Salsbury Industries.
All rights reserved.
3712S-1B
1
3712S-1C
Page 3 of 7
1