SALICRU SLC CUBE4, SLC-7.5-CUBE4, SLC-10-CUBE4, SLC-15-CUBE4, SLC-20-CUBE4 Users guide

...
SLC CUBE4
Uninterruptible Power Supplies (UPS) with IoT from 7.5 to 80 kVA
SLC CUBE4
Uninterruptible Power Supplies with IoT from 7.5 to 80 kVA
The most advanced continuity protection on the market
Salicru’s SLC CUBE4 Uninterruptible Power Supplies are the most cutting-edge security solution for all critical systems and sensitive loads. They have a Nimbus cloud connection that allows for equipment monitoring as standard, as well as options of remote management incident notification, equipment health monitoring and preventive maintenance.
With three-level on-line technology and quad-core DSP control, they are three-phase input/output systems that offer a range of first-class features, including unity power factor (kVA=kW), very low input
Features
· On-line double conversion technology with three-level topology.
· State-of-the-art quad-core DSP control.
· Output power factor 1 (kVA=kW).
· Input power factor >0.99.
· Input current distortion rate (THDi) <3%.
· Nimbus IoT connection for monitoring, as standard.
· High energy efficiency (over 96% in On-line Mode and up to 99% in Eco Mode).
· Unlimited
· Batt-Watch battery care and management system.
· Batteries included on standard models throughout the range.
· Compatible with all battery types, including lithium-ion.
· Compatible with power generators.
· 5” touch screen for all models.
· USB, RS-232 and RS-485 interfaces, plus relays.
· Wide range of options available.
· SLC Greenergy solution.
(1)
parallel systemfor redundancy or capacity purposes.
distortion (THDi <3%) and performance in excess of 96% in On-line Mode and 99% in Eco Mode. They also boast parallel growth capacity or unlimited redundant security.
Across the entire range, the batteries are included in the same cabinet, meaning the floor area occupied is reduced by up to 40%. They are compatible with all types of battery (including lithium-ion) and incorporate the Batt-Watch battery care system to maximise battery life and availability.
(1) For models up to 20 kVA. maximum of four devices in parallel.
2
CAPACITIVE POWER (kVAr)
ACTIVE POWER (kW)
INDUCTIVE POWER (kVAr)
100%
Efficiency
100
Three-level topology with DSP control
Three-level switching, which is based on switching the IGBTs in half-cycles (positive and negative), controlled by floating point DSP with exclusive cores for the rectifier and inverter, provides maximum performance in double conversion.
Lowers cooling costs and increases energy efficiency by more than 96% from a 25% charge, thereby improving TCO by reducing OpEx.
98
96
94
92
% EFFICIENCY
90
88
25 50 75 100
% CHARGE
Eco-mode
Mode On-line double conversion 3 levels SLC 80 CUBE4
Mode On-Line 2 levels conventional
Output power factor PF=1 for full rated power (kVA=kW)
VFI double conversion technology
Double conversion of the voltage between input and output (AC/DC – DC/AC) in accordance with VFI-SS-111 (EN-IEC 62040-3) operation, providing clean, stable and reliable voltage at output.
Supplies loads with voltage of the highest quality, protecting them from any and all disturbances in the mains electricity.
RECTIFIER INVERTER
DOUBLE CONVERSION
Operation in Eco Mode
When maximising the facility’s performance is the leading priority, Eco Mode allows loads to be supplied directly from the static bypass, provided the static bypass is within acceptable voltage and frequency ranges.
Increases the overall performance of the system by up to 99%, thereby improving the facility’s OpEx.
The UPS is capable of supplying full rated power in the form of kW.
For modern loads with power factor correction, such as servers, it is not necessary to apply a UPS overdimension factor, resulting in lower TCO (total cost of ownership).
CAPACITIVE POWER FACTOR
0.9
0.8
1
0
2020 4040 6060 8080 100%
INDUCTIVE POWER
0.9
FACTOR
0.8
Improved conditions for the electrical installation
With very low harmonic distortion (THDi <3%) and an input power factor equivalent to unity (FPin>1)
(1)
, it is not necessary to overdimension the
transformers, power cables and/or power generators.
Brings down total capital expenditure (CapEx).
(1) Depending on the model.
Silicon carbide devices
Silicon carbide (SiC) devices are the latest development with regard to performance and efficiency.
They enable systems to operate in a much wider range of temperatures and at much higher switching speeds, without affecting performance.
3
QUAD CORE DSP CONTROL
LOADS
Reliability
Cutting-edge technology
Advanced digital control techniques, developed in collaboration with leading European research centres and implemented in quad-core signal processors.
Thereby making it possible to apply the most advanced features.
DSP DUAL CORE 1
CPU2CPU1
DSP DUAL CORE 2
CPU3 CPU4
Redundant power supply
Modular design
Power modules with a repeating design, divided by phase and internally arranged in parallel in order to increase power.
The design optimises manufacturing processes and reliability while reducing the time required for intervention in the event of an incident (MTTR – mean time to repair).
Security with double bypass
Redundant power supplies for control and the static bypass switch
Ensure the continuity of power even in the event of failure of the device itself, providing maximum availability.
(1) Depending on the model.
Unlimited
Offers the capacity to arrange devices in parallel, in order to ensure maximum availability (redundancy N+1, ..., N+M) as well as increasing power (increased load demand). Provides the same output performance in parallel systems as in standalone devices. Continuity of operation even if the communication signal is lost (depending on the model).
The availability of the protection is assured by both the redundancy and the requirements regarding growth in demand.
(1) For models up to 20 kVA. Maximum of four devices in parallel.
(1)
parallelingof devices
(1)
.
Double bypass circuit as standard for all models. The static bypass deals with unforeseen overloads or anomalous situations affecting the operation of the equipment. There is also a maintenance bypass, which enables the equipment to be worked on without causing the loads to be disconnected.
Continuity of load supply under any circumstances.
Maintenance BYPASS
BATTERIES
Static BYPASS
Over 55 years of experience
Know-how in electrical continuity and protection solutions, accumulated during Salicru’s 55-plus years of history.
More than 900,000 UPS systems sold in over 130 countries, representing total power equivalent to more than 5 million protected computers.
UPS 1 UPS 2 UPS 3 UPS N
4