SALDA Smarty 3X V 1.2, Smarty 4X V 1.1, Smarty 4X V 1.2, Smarty 3X P 1.2, Smarty 2X V 1.1 Datasheet

...
SMARTY X
A1
Description
AIR HANDLING UNITS
Apartments, private houses, villas, passive houses.
V [m3/h]
Residential air handling units Smarty X with EPP casing are characteristic of the highest energy eciency (heat
recovery rate – up to 94%) and user-friendly control. Universal positioning of Smarty XP units and the lowest height
enable to nd a place for them even in tight spaces. Due to compact sizing Smarty 2XV ideally ts in a place of a kitchen cabinet, meanwhile Smarty 3XV/4XV could t above a regular washing machine.
Every Smarty unit is tested for airtightness in order to assure exceptional quality of assembly. All internal compo-
nents (fans, actuators, heat exchanger) are produced by top European manufacturers, which guarantees a long
service life. Smart control board enables controlling all components of the ventilation system.
The main features: › Class A+/A eciency*; EC fans with high-eciency counter-ow heat exchangers; High quality: Class A1 airtightness; Smart and user-friendly handling by using SALDA AIR mobile app (via optional MB-Gateway); Certied by Passivhaus Institute (Smarty 2X and 3X).
*- depends on the unit.
Top class casing: › Thermal and acoustic insulation: EPP of 20-30 mm;Galvanized steel plate; › The external side is powder-coated – corrosion class C3.
Heat exchanger: › Plastic plate heat exchanger;Eciency up to 91% (EU 1253/2014) / 85% (Passivhaus).
Fans: › EC type;Specic fan input (SPI) from 0.26 W/(m3/h);Long lifetime – fans last for more than 10 years.
54
Construction
Motorized bypass damper: › 100% summer bypass (night cooling);
Integrated pre-heater (Smarty 2XV/3XV/4XV version 1.1 only).
Filters: › Low pressure drop Coarse 65%/Coarse 65% (G4/G4) lters (eective ltration of dust, pollens);Optional supply of ePM1 70% (F7) lter for more ecient ltration (moulds, spores, microscopic allergens, ne
particles, bacteria).
Integrated control board2: › Control of external components: pre-heater, heater, dampers, etc.;Connection for demand control sensors (CO2, RH, presence);Intelligent frost protection;Smart el.heater control 0-10V;Extensive control options: 3 manual modes, boost, calendar, night cooling, replace mode and etc.
1
~40000 working hours
2
Functionality depends on the unit
The company reserves the right to make changes of technical data without prior notice
SMARTY X
Air temperature
sensors
Relative
humidity sensor
Control options
Extract, Supply, Outdoor.
Extract air (Smarty 3XV/4XV V 1.1)
CONSTRUCTION
Smarty 2X P - 4X P
AIR HANDLING UNITS
Dimensions [mm]
Unit L L1 W H A B øD
Smarty 2X P 1009 1085 590 250 113 115 125/160
Smarty 3X P 1225 1381 685 324 150 128 150/160
Smarty 4X P 1225 1381 685 324 150 128 150/160
Smarty 2X V Smarty 3X V - 4X V
*
* - optional
Dimensions [mm]
Unit L W H H1 F A B C D E øD
Smarty 2X V 595 316 732 697 35 82 79 82 195 242 125/100
Smarty 3X V 599 538 900 810 80 100 145 138 112 265 150/160
Smarty 4X V 599 538 900 810 80 100 145 138 112 265 150/160
The company reserves the right to make changes of technical data without prior notice
55
SMARTY X
ACCESSORIES
Optional accessories
Unit EKA/EKA NIS WSG ALU NPU AP MUTE SKG
Smarty 2X P 125 - 125 125 125 125 125
Smarty 3X P 160 160 160 160 160 160 160
Smarty 4X P
Smarty 2X V 125 - 125 125 125 125 125
Smarty 3X V 160 160 160 160 160 160 160
Smarty 4X V 160 160 160 160 160 160 160
160 160 160 160 160 - 160
MB-Gateway STOUCH EKA NIS
Panel lters Panel lters
MPL
Coarse 65% (G4)
AIR HANDLING UNITS
MPL
ePM1 70% (F7)
Control panel
ST-SA-Control
Actuators for
dampers
CM230-F-L
Electrical preheater
/ heater
Shut-o damper
SKG-A
CO2 sensors
S-RCO2-F2
S-KCO2
Silencer
MUTE
S-RFF-U-D-F2
S-KFF-U
Nano RouterControl panelNetwork Module
TL-WR802N
Smarty legsHumidity transmitter
56
VERSIONS
Product name
Energy eciency class
Control board
Version
Heat recovery
Temp.control
Bypass damper
Integrated
pre-heater
Extracted air humidity sensor
Duct-based
pre-heater
Duct-based heater
* - version V1.1 with additional CO2 or RH sensors complies to A+/A. ** - only with pre-heater or heater.
Smarty 2X V 1.1
Premium Advanced Premium Advanced Premium Advanced Premium Advanced Premium Advanced Premium Advanced
+*
A
Mini MCB
Smarty
2X V 1.2
A A
Mini MCB
Basic
**
**
Smarty
3X V 1.1
+*
Mini
MCB
The company reserves the right to make changes of technical data without prior notice
Smarty
3X V 1.2
Smarty
4X V 1.1
Mini MCB
*
A A
Mini MCB
Basic
Optional heating elements
**
**
Smarty
4X V 1.2
B A
Mini MCB Basic
**
**
Smarty 2X P 1.1
+*
Mini MCB
Smarty 2X P 1.2
A A
Mini MCB
Basic
**
**
Smarty 3X P 1.1
+*
Mini MCB
Smarty 3X P 1.2
A A
Mini MCB
Basic
**
**
Smarty 4X P 1.1
*
Mini MCB
Smarty 4X P 1.2
B
Mini MCB
Basic
**
**
Smarty 2X P
SMARTY X
49
Ordering code AHU000108 AHU000109 Electrical data
Fans [50Hz/VAC] ~1, 230
exhaust [kW/A] 0.051/0.4
supply [kW/A] 0.051/0.4 Electrical preheater integrated [kW/A] Optional on duct Electrical heater [kW/A] Optional on duct
Max.power consumption [kW/A] 0.10/0.85
Power connection [50Hz/VAC] ~1, 230 Control board MiniMCB MiniMCB basic
Ecodesign data
Energy eciency class
Thermal eciency of heat recovery [%] 86,3
Sound power level (Lwa) [dB(A)] 49
SPI [W/(m3/h)] 0.33
Maximum internal/external leakage rates [%] 1.2/1.2
ErP compliance 2018
Other data
Filters Supply/Extract Coarse 65%/Coarse 65% (G4/G4)*
Housing insulation, polyurethane [mm] 20
Colour white RAL 9016
Weight (net, without packing) [kg] 30
Housing protection class IP 34
Operation Indoors only (heated premises)
* - ePM1 70% (F7) lter is available as an accessory
Without frost
protection
00C+400C/ 90% -150C+400C/ 90% -400C/+400C/90% +150C/+400C/60%
With air ow
disbalancing protection
Time control A
Local demand
control
Version 1.1 Version 1.2
With optional
preheater on duct
218
A
Extract air
Supply air
Δ Pstat [Pa]
V [l/s]
Exhaust air
P [W]
Δ Pstat [Pa]
Veried:
EPDB
PCDB
Ekofund
CasaClima
AIR HANDLING UNITS
View from inspection side
Extract airExhaust air outdoor air Supply air
Performance
Power consumption
V [l/s]
P [W]
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
air ow m3/h
V [m3/h]
Temperature eciency
V [l/s]
η [%]
Temperature eciency (balanced mass ow):
+7 - 20oC/39% dry / +2 - 20oC/60% wet / -7 - 20oC/39% wet
x 3600
V [m3/h]
Smarty 2X P Lwa total,
Outdoor 55 14 46 53 49 40 25 15 7 Supply 68 21 51 61 66 60 54 47 32 Extract 55 20 46 52 49 39 32 16 7 Exhaust 65 19 50 59 61 57 51 43 29 Surround 48 9 32 41 46 38 35 34 32
Measured at 151 m3/h, 50 Pa
dB(A)
63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
LWA, dB(A)
The company reserves the right to make changes of technical data without prior notice
V [m3/h]
V [l/s]
V [m3/h]
57
Loading...