SALDA Smarty 3X V 1.2, Smarty 4X V 1.1, Smarty 4X V 1.2, Smarty 3X P 1.2, Smarty 2X V 1.1, Smarty 3X P 1.1, Smarty 2X P 1.2, Smarty 4X P 1.2, Smarty 4X P 1.1, Smarty 3X V 1.1, Smarty 2X P 1.1, Smarty 2X V 1.2 Datasheet
Residential air handling units Smarty X with EPP casing are characteristic of the highest energy eciency (heat
recovery rate – up to 94%) and user-friendly control. Universal positioning of Smarty XP units and the lowest height
enable to nd a place for them even in tight spaces. Due to compact sizing Smarty 2XV ideally ts in a place of a
kitchen cabinet, meanwhile Smarty 3XV/4XV could t above a regular washing machine.
Every Smarty unit is tested for airtightness in order to assure exceptional quality of assembly. All internal compo-
nents (fans, actuators, heat exchanger) are produced by top European manufacturers, which guarantees a long
service life.
Smart control board enables controlling all components of the ventilation system.
The main features:
› Class A+/A eciency*;
› EC fans with high-eciency counter-ow heat exchangers;
› High quality: Class A1 airtightness;
› Smart and user-friendly handling by using SALDA AIR mobile app (via optional MB-Gateway);
› Certied by Passivhaus Institute (Smarty 2X and 3X).
*- depends on the unit.
Top class casing:
› Thermal and acoustic insulation: EPP of 20-30 mm;
› Galvanized steel plate;
› The external side is powder-coated – corrosion class C3.
Heat exchanger:
› Plastic plate heat exchanger;
› Eciency up to 91% (EU 1253/2014) / 85% (Passivhaus).
Fans:
› EC type;
› Specic fan input (SPI) from 0.26 W/(m3/h);
› Long lifetime – fans last for more than 10 years.
Integrated pre-heater (Smarty 2XV/3XV/4XV version 1.1 only).
Filters:
› Low pressure drop Coarse 65%/Coarse 65% (G4/G4) lters (eective ltration of dust, pollens);
› Optional supply of ePM1 70% (F7) lter for more ecient ltration (moulds, spores, microscopic allergens, ne
particles, bacteria).
Integrated control board2:
› Control of external components: pre-heater, heater, dampers, etc.;
› Connection for demand control sensors (CO2, RH, presence);
› Intelligent frost protection;
› Smart el.heater control 0-10V;
› Extensive control options: 3 manual modes, boost, calendar, night cooling, replace mode and etc.
1
~40000 working hours
2
Functionality depends on the unit
The company reserves the right to make changes of technical data without prior notice
SMARTY X
Air temperature
sensors
Relative
humidity sensor
Control options
Extract, Supply, Outdoor.
Extract air (Smarty 3XV/4XV V 1.1)
CONSTRUCTION
Smarty 2X P - 4X P
AIR HANDLING UNITS
Dimensions [mm]
UnitLL1WHABøD
Smarty 2X P10091085590250113115125/160
Smarty 3X P12251381685324150128150/160
Smarty 4X P12251381685324150128150/160
Smarty 2X VSmarty 3X V - 4X V
*
* - optional
Dimensions [mm]
UnitLWHH1FABCDEøD
Smarty 2X V59531673269735827982195242125/100
Smarty 3X V59953890081080100145138112265150/160
Smarty 4X V59953890081080100145138112265150/160
The company reserves the right to make changes of technical data without prior notice
55
SMARTY X
ACCESSORIES
Optional accessories
UnitEKA/EKA NISWSGALUNPUAPMUTESKG
Smarty 2X P125-125125125125125
Smarty 3X P160160160160160160160
Smarty 4X P
Smarty 2X V125-125125125125125
Smarty 3X V160160160160160160160
Smarty 4X V160160160160160160160
160160160160160-160
MB-GatewaySTOUCHEKA NIS
Panel ltersPanel lters
MPL
Coarse 65% (G4)
AIR HANDLING UNITS
MPL
ePM1 70% (F7)
Control panel
ST-SA-Control
Actuators for
dampers
CM230-F-L
Electrical preheater
/ heater
Shut-o damper
SKG-A
CO2 sensors
S-RCO2-F2
S-KCO2
Silencer
MUTE
S-RFF-U-D-F2
S-KFF-U
Nano RouterControl panelNetwork Module
TL-WR802N
Smarty legsHumidity transmitter
56
VERSIONS
Product name
Energy eciency class
Control board
Version
Heat recovery
Temp.control
Bypass damper
Integrated
pre-heater
Extracted air humidity
sensor
Duct-based
pre-heater
Duct-based heater
* - version V1.1 with additional CO2 or RH sensors complies to A+/A.
** - only with pre-heater or heater.
* - 2X P does not have constant air ow/pressure functions
** - v.1.2 version can control one heater
NIS
EKA
SMARTY X
EKA
NIS
IV - exhaust air fan
PV - supply air fan
PR - plate heat exchanger
PF - lter for supply air
IF - lter for extract air
M1 - actuator of by-pass damper
TA - extract air temperature sensor
TL - outdoor air temperature sensor
TJ - supply air temperature sensor
EKA NIS - electric pre-heater
EKA -electric heater
PT1 - supply air fan pressure transmitter (only v1.1 version)
PT2 - exhaust air fan pressure transmitter (only v1.1 version)
Smarty 2X V version v1.1 with electrical heater
EKA
NIS
AIR HANDLING UNITS
IV - exhaust air fan
PV - supply air fan
PR - plate heat exchanger
PF - lter for supply air
IF - lter for extract air
M1 - actuator of by-pass damper
TA - extract air temperature sensor
The company reserves the right to make changes of technical data without prior notice
TL - outdoor air temperature sensor
TJ - supply air temperature sensor
EKA -electric heater
PE -electric pre-heater
63
SMARTY X
Smarty 3X V / 4X V versions v1.1 with electrical heater
EKA
NIS
IV - exhaust air fan
PV - supply air fan
AIR HANDLING UNITS
PR - plate heat exchanger
PF - lter for supply air
IF - lter for extract air
M1 - actuator of by-pass damper
DTJ - air temperature and humidity sensor
TL - outdoor air temperature sensor
TJ - supply air temperature sensor
EKA -electric heater
PE -electric pre-heater
PT1 - supply air fan pressure transmitter
PT2 - exhaust air fan pressure transmitter
64
The company reserves the right to make changes of technical data without prior notice
Smarty 2X V / 3X V / 4X V versions v1.2* with electrical heater
* - v.1.2 version can control one heater
SMARTY X
IV - exhaust air fan
PV - supply air fan
PR - plate heat exchanger
PF - lter for supply air
IF - lter for extract air
M1 - actuator of by-pass damper
EKA
EKA
NIS
NIS
EKA
EKA
NIS
TA
TA - extract air temperature sensor
TL - outdoor air temperature sensor
TJ - supply air temperature sensor
EKA -electric heater
EKA NIS -electric pre-heater
AIR HANDLING UNITS
The company reserves the right to make changes of technical data without prior notice
65
SMARTY X
Descriptions of the functions
Fans
AIR HANDLING UNITS
Electric heater
Electric pre-heater
Air dampers
Filters clogging monitoring
Sensors
Remote controllers
Building management system
FUNCTIONS
MiniMCB
Functions
Date and time settings++
System modes for easy and-user friedly control: Stand-by, Building protection, Economy, Comfort.++
BOOST function (Fans operate at highest speed)++
Cold/heat recovery++
Fire place function+-
Fireplace protection (NC)o-
Fire protection++
Winter/summer mode++
System monitoringoo
Alarm indication output+-
Operation indication output+-
Digital input confguration++
Event register (storing up to 50 entries)++
Dryness protectionoo
Constant air pressure+-
Constant airow mode+-
Heat exchanger frost protection++
Manual components controloo
Weekly schedule++
Holiday schedule++
CO2 level indication and reduction functionoo
Night cooling function++
Relative humidity (RH) level indication and reduction functiono o
Supply air temperature control according to the extract air sensor++
Reset to factory defaults++
Functional units
Speed synchronous/asynchronous 0-10V control++
Protection by RPM ++
Protection by pressure+-
On/o and 0-10V control+*
Automatic and Manual protection (NC)+*
On/o and 0-10V control+*
Pre-heater manual/automatic protection (NC)+*
Outdoor air dampers control++
Air lters timer++
Supply air temperature sensor++
Outdoor air temperature sensor++
Extract air temperature sensor++
S-Touchxx
ST-SA-Controlxx
MB Gatewayxx
Modbus++
BACnet/IPoo
MiniMCB
Smarty range
basic
1
1
66
oRequired additional components: CO2 and moisture sensors, switches, etc.
+Standard feature (the number of features depends on the ventilation unit in which the automatics are used); to be confgured through BMS network or
remote control panel
xRemote control panels
*Only one heater or pre-heater can be connected
o1Only one sensor can be connected
The company reserves the right to make changes of technical data without prior notice