SALDA RIS 1200 PE 3.0 EKO 3.0, RIS 1200 PE 9.0 EKO 3.0, RIS 700 PE 1.2 EKO 3.0, RIS 2500 PE 9.0 EKO 3.0, RIS 2500 PW EKO 3.0, RIS 1900 PE 3.0 EKO 3.0, RIS 2500 PE 18.0 EKO 3.0, RIS 700 PW EKO 3.0, RIS 700 PE 4.5 EKO 3.0, RIS 2500 PE 4.5 EKO 3.0, RIS 700 PE 3.0 EKO 3.0, RIS 1200 PW EKO 3.0, RIS 1900 PW EKO 3.0, RIS 1900 PE 12.0 EKO 3.0, RIS 1900 PE 6.0 EKO 3.0, RIS 1200 PE 6.0 EKO 3.0, RIS 400 PW EKO 3.0, RIS 400 PE 3.0 EKO 3.0, RIS 400 PE 1.6 EKO 3.0, RIS 400 PE 0.9 EKO 3.0 Datasheet
RIS P EKO
EC
Application Ventilation of houses, oces or other heated premises (classrooms, apartments, conference rooms, etc.)
Description
AIR HANDLING UNITS
A1/L2
V [m3/h]
RIS P EKO 3.0 is a range of heat recovery units with high-eciency counter-ow heat exchangers and low
height. The units are designed for mounting under ceilings in order to save space. There are 5 sizes (airow
interval 420-2500 m3/h) with separate heaters available for dierent climate zones.
RIS P EKO 3.0 units have high overall energy savings due to the highly ecient heat recovery (up to 90%),
quiet and economical EC fans, eective low-pressure-drop lters, 100% motorized bypass dampers (for the
1900 and 2500 versions) and top-level of air tightness.
Energy eciency ensures full thermal comfort for passive houses, without an additional pre-heater at
temperatures above -5°C.
All the RIS P EKO 3.0 units are fully equipped with automatic controls. Optional external sensors for CO2 and
humidity and the event planning feature will help to control automatically your climate (demand-level control).
RIS P EKO 3.0 units are service-friendly and are easy to mount. Filter pollution may be identied by timers
or contamination controls (RIS 1200-2500 P EKO 3.0).
All units are supplied tested and ready to install.
Three remote control options are available:
Remote control
Features
Construction
1. Flex, Stouch or Ptouch remote controllers.
2. Building management system connections.
3. Remote control via PC MB-Gateway.
› Ideal for ceiling installations.
› Ready for Passive House technology: high eciency.
› Easy and quick mounting.
› Water/electrical heating options.
› Fully integrated plug-and-play control system.
› Frameless construction from double-skinned panels.
› Acoustic and thermal wall insulation: RIS 400–2500 P EKO 3.0 – 30/50 mm.
› RIS 400-700 P EKO 3.0 powder-coated white housing RAL 9016; RIS 1200–2500 P EKO 3.0 powder-coated
grey housing RAL 7040.
› Integrated electrical heater or optional duct-based water heater/cooler.
› Low-pressure-drop lters: F7/M5.
› Hinged door with locks grants easy access to internal components.
› Separate compartment on the side of the unit grants quick access to the control board (plug-and-play).
› Stainless steel condensate tray.
› Fitted with mounting brackets.
› Integrated anti-frost pressure switch (RIS 1200-2500 P EKO 3.0).
RIS 400 P E 0.9 EKO 3.0
Equipped with new PRV V2 control board
AHU with EC motors and ecient heat exchanger
Electrical heater power in kW
Heater type (E - integrated electrical heater; W - prepared for water heater)
Housing type (V - vertical, H - horizontal, P - ceiling)
AHU size according to maximum airow range m3/h
AHU with plate heat exchanger
64
The company reserves the right to make changes of technical data without prior notice
Thermal eciency up to*90%
Motorized by-pass+
Max power consumption
Control boardPRV V2
Filter class
Housing insulation, mineral wool
Colour
Weight (net, without packing)
Comply with ERP2016; 2018
Operationindoors
Fresh air temperature limits**
Housing protection class IP
phase/voltage [50Hz/VAC]
phase/voltage [50Hz/VAC]
power/current[kW/A]
fan speed[min-1]
power/current[kW/A]
fan speed[min-1]
exhaust/supply
RALwhite
0.9 EKO 3.0 1.6 EKO 3.0 3.0 EKO 3.0
~1, 230~1, 230~1, 230
[kW]
[kW/A]
[mm]
[kg]
°C
0,91,63,0
0,085/0,73
0,085/0,73
1,07/5,50 1,77/8,503,17/14,50
* Calculated according EN 13141-7.
**For temperatures lower than recommended, use electrical pre-heater
to ensure balanced operation.
V [m3/h]
V [l/s]
~1, 230
3200
3200
M5/F7
30
9016
74
-5 - +40
34
66
Temperature eciency (balanced mass ow) EN 13141-7:
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
V [m3/h]
RIS 400PE EKO 3.0
Supply6754596458575447
Extract5848505351484641
Surrounding5140434645403936
Measured at 395 m3/h, 100 Pa
The company reserves the right to make changes of technical data without prior notice
Extract air = 20°C/60%RH
Outdoor air = -7°C / 2°C / 7°C
LWA, dB(A)
RIS P EKO
50%
50%
RIS 400PW EKO 3.0
Supply air
Δ Pstat [Pa]Δ Pstat [Pa]
Exhaust air
Performance
Power consumption
V [l/s]
V [m3/h]
V [l/s]
P [W]
P [W]
AIR HANDLING UNITS
RIS 400PW EKO 3.0
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
air ow m3/h
Temperature eciency
η [%]
x 3600
View from inspection side
Extract airExhaust airOutdoor airSupply air
Article No.Version
GAGRIS1748_0019A400PW EKO 3.0 Optional water heater
fan speed[min-1]3200
Thermal eciency up to*90%
Motorized by-pass+
Max power consumption [kW/A]0,17/1,50
Control boardPRV V2
Filter classexhaust/supplyM5/F7
Housing insulation, mineral wool[mm]30
ColourRALwhite9016
Weight (net, without packing) [kg]73
Comply with ERP2016; 2018
Operationindoors
Fresh air temperature limits**°C-5 - +40
Housing protection classIP34
* Calculated according EN 13141-7.
**For temperatures lower than recommended, use electrical pre-heater
to ensure balanced operation.
V [m3/h]
V [l/s]
400PW EKO 3.0
Temperature eciency (balanced mass ow) EN 13141-7:
Outdoor air = -7°C / 2°C / 7°C
LWA, dB(A)
V [m3/h]
RIS 400PW EKO 3.0
Supply6754596458575447
Extract5848505351484641
Surrounding5140434645403936
Measured at 395 m3/h, 100 Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
The company reserves the right to make changes of technical data without prior notice
Thermal eciency up to*90%
Motorized by-pass+
Max power consumption
Control boardPRV V2
Filter class
Housing insulation, mineral wool
Colour
Weight (net, without packing)
Comply with ERP2016;2018
Operationindoors
Fresh air temperature limits**
Housing protection class IP
phase/voltage [50Hz/VAC]
phase/voltage [50Hz/VAC]
power/current[kW/A]
fan speed[min-1]
power/current[kW/A]
fan speed[min-1]
exhaust/supply
RALwhite
* Calculated according EN 13141-7.
**For temperatures lower than recommended, use electrical pre-heater
to ensure balanced operation.
air ow m3/h
The company reserves the right to make changes of technical data without prior notice
x 3600
V [m3/h]
V [l/s]
V [m3/h]
Temperature eciency (balanced mass ow) EN 13141-7:
RIS 700PE EKO 3.0
Supply7564666870666059
Extract6253555756524945
Surrounding5645475050474342
Measured at 700 m3/h, 100 Pa
Lwa total,
dB(A)
View from inspection side
1.2 EKO 3.0 3.0 EKO 3.0 4.5 EKO 3.0
~1, 230~1, 230~3, 400
[kW]
[kW/A]
[mm]
[kg]
°C
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
1,23,04,5
~1, 230
0,168/1,4
3230
0,168/1,4
3230
1,54/8,34 3,34/15,844,84/9,3
M5/F7
30
9016
103,5104104,5
-5 - +40
34
Extract air = 20°C/60%RH
Outdoor air = -7°C / 2°C / 7°C
LWA, dB(A)
Loading...