Ventilation of houses, small public buildings, oces or other heated premises (classrooms, apartments,
conference rooms, etc.).
RIRS V EKO 3.0 is a range of heat recovery units with high-eciency rotor heat exchangers. Units are designed for vertical placement in auxiliary non-heated premises (basements, boiler rooms, etc.).
There are 7 sizes (airow interval 420-5600 m3/h) with separate heaters available for dierent climate zones.
RIRS V EKO 3.0 units have high overall energy savings due to the highly ecient heat recovery (up to 85%),
quiet and economical EC fans, eective low pressure drop lters and top-level of air tightness.
All RIRS V EKO 3.0 units are fully equipped with automatic controls.
Optional external sensors for CO2 and humidity and so the summer mode feature will guarantee the highest comfort (demand-level control).
RIRS V EKO 3.0 units are service-friendly and easy to mount. Filter pollution may be identied by timers or
contamination controls (RIRS 1200-5500 V EKO 3.0). Rotor fault indicator is included in every AHU.
All units are supplied tested and ready to install.
Three remote control options are available:
1. Flex, Stouch or Ptouch remote controllers.
2. Building management system connections.
3. Remote control via PC MB-Gateway.
› Ecient rotor heat exchanger with up to 85% heat recovery.
› Water/electrical heating options.
› Easy and quick mounting.
› Controlled airow.
› Fully integrated plug-and-play control system.
› Outdoor versions and convertible inspection side.
› Eurovent certied.
› Plate gap 1,4-1,9 mm.
› Rotor fault indicator.
› Minimal airow mixing.
› Appropriate “Purge sector” size (for RIRS 2500, 3500 and 5500 V EKO 3.0).
11 2
Construction
› Frameless construction from double-skinned steel, with powder coated paint, panels.
› Acoustic and thermal wall insulation – 50 mm.
› Hinged door with locks grants easy access to internal components.
› Separate compartment on the side of the unit grants quick access to the control board (plug-and-play).
› Three sensors for fresh, supply and extract air temperatures.
› Anti-vibration pads (optional for RIRS 400-1900 V EKO 3.0; standard for RIRS 2500-5500 V EKO 3.0).
› Water heater with frost protection kit available.
› Low pressure drop lters: F7/M5.
› Integrated electrical heater or optional water heater/cooler (on duct).
› Outdoor versions (RIRS 2500, 3500, 5500 V EKO 3.0).
› RHX versions (rotor speed control, using stepper motor and driver).
› Integrated pressure switch for lter pollution alarm (RIRS 1200 - 5500 V EKO 3.0).
The company reserves the right to make changes of technical data without prior notice
RIRS V EKO
RIRS 400-700V EKO 3.0
* The view from the top is only indicative.
For exact information, see the specic product technical description.
The company reserves the right to make changes of technical data without prior notice
RIRS V EKO
RIRS 400V EKO 3.0
Supply air
Δ Pstat [Pa]Δ Pstat [Pa]
Exhaust air
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
Temperature eciency
η [%]
air ow m3/h
x 3600
Performance
Power consumption
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
P [W]
P [W]
RIRS 400VL EKO 3.0
Air intake side (L- left)
Extract airExhaust air
Article No.Version
GAGRIRS1759_0037A400VEL EKO 3.0
GAGRIRS1760_0039A400VWL EKO 3.0
GAGRIRS1757_0036A400VER EKO 3.0
GAGRIRS1758_0038A400VWR EKO 3.0
Water heater (optional) VW ver.
Electrical heater VE ver.phase/voltage
EC fansphase/voltage
exhaustpower/current
supplypower/current
Thermal eciency up to*
Max power consumption VE / VW
Control board
Filter classexhaust/supply
Housing insulation, mineral wool
ColourRAL
Weight (net, without packing)
Comply with ERP
Operation
Housing protection classIP
fan speed
fan speed
* Calculated wet eciency.
RIRS 400VR EKO 3.0
Air intake side (R- right)
View from inspection sideView from inspection side
Outdoor air
Left-hand maintenace version with integrated electrical heater
Left-hand maintenace version prepared
for optional water heater
Right-hand maintenace version with
integrated electrical heater
Right-hand maintenace version prepared
for optional water heater
Supply air
400VE / VW EKO 3.0
[50Hz/VAC]
[kW]
[50Hz/VAC]
[kW/A]
[min-1]
[kW/A]
[min-1]
[kW/A]
[mm]
white
[kg]
1,38/5,94 0,18/1,60
AVS 160
~1, 230
1,2
~1, 230
0,085/0,75
3200
0,085/0,75
3200
75%
PRV V2
M5/F7
50
9016
79,5
2016; 2018
indoors
34
AIR HANDLING UNITS
Temperature eciency (balanced mass ow):
LWA, dB(A)
V [m3/h]
400V EKO 3.0
Supply7064596166635452
Extract6155575749433430
Surrounding5451484142433328
Measured at 375 m3/h, 120 Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
The company reserves the right to make changes of technical data without prior notice
Extract air = 20°C/60%RH
Outdoor air = -20°C
11 5
RIRS V EKO
200
180
160
140
120
100
80
60
40
20
0
200
180
160
140
120
100
80
60
40
20
0
90
85
80
75
70
65
-20
AIR HANDLING UNITS
11 6
RIRS 700V EKO 3.0
Supply air
Δ Pstat [Pa]Δ Pstat [Pa]
Exhaust air
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
Temperature eciency
η [%]
air ow m3/h
The company reserves the right to make changes of technical data without prior notice
x 3600
Performance
Power consumption
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
P [W]
P [W]
RIRS 700VL EKO 3.0
Air intake side (L- left)
Extract airExhaust airOutdoor airSupply air
Article No.Version
GAGRIRS1770_0033A700VEL EKO 3.0
GAGRIRS1771_0035A700VWL EKO 3.0
GAGRIRS1766_0032A700VER EKO 3.0
GAGRIRS1768_0034A700VWR EKO 3.0
RIRS 700VR EKO 3.0
Air intake side (R- right)
View from inspection sideView from inspection side
Left-hand maintenace version with integrated electrical heater
Left-hand maintenace version prepared
for optional water heater
Right-hand maintenace version with
integrated electrical heater
Right-hand maintenace version prepared
for optional water heater
700VE / VW EKO 3.0
Water heater (optional) VW ver.
Electrical heater VE ver.phase/voltage [50Hz/VAC]
EC fansphase/voltage [50Hz/VAC]
exhaustpower/current[kW/A]
supplypower/current[kW/A]
Thermal eciency up to*
Max power consumption VE / VW[kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALwhite
Weight (net, without packing)[kg]
Comply with ERP
Operation
Housing protection classIP
fan speed[min-1]
fan speed[min-1]
* Calculated wet eciency.
Temperature eciency (balanced mass ow):
700V EKO 3.0
Supply7667697069686362
Extract6352605847443835
Surrounding5547504944433939
Measured at 700 m3/h, 152 Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
[kW]
2,34/11,60 0,34/2,90
108104
Extract air = 20°C/60%RH
Outdoor air = -20°C
LWA, dB(A)
2016; 2018
AVS 250
~1, 230
2,0
~1, 230
0,168/1,4
3230
0,168/1,4
3230
75%
PRV V2
M5/F7
50
9016
indoors
34
RIRS V EKO
RIRS 1200V EKO 3.0
Supply air
Δ Pstat [Pa]Δ Pstat [Pa]
Exhaust air
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
Temperature eciency
η [%]
air ow m3/h
x 3600
Performance
Power consumption
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
P [W]
P [W]
RIRS 1200VL EKO 3.0
Air intake side (L- left)
Extract airExhaust airOutdoor airSupply air
Article No.Version
GAGRIRS1678_0003C1200VEL EKO 3.0
GAGRIRS1679_0004A 1200VWL EKO 3.0
GAGRIRS1675_0001C1200VER EKO 3.0
GAGRIRS1677_0002A 1200VWR EKO 3.0
Water heater (optional) VW ver.
Electrical heater VE ver.phase/voltage [50Hz/VAC]
EC fansphase/voltage [50Hz/VAC]
exhaustpower/current[kW/A]
fan speed[min-1]
supplypower/current[kW/A]
fan speed[min-1]
Thermal eciency up to*
Max power consumption VE/VW [kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALgrey
Weight (net, without packing) [kg]
Comply with ERP
Operation
Housing protection classIP
Left-hand maintenace version with integrated electrical heater
Left-hand maintenace version prepared
for optional water heater
Right-hand maintenace version with
integrated electrical heater
Right-hand maintenace version prepared
for optional water heater
* Calculated wet eciency.
RIRS 1200VR EKO 3.0
Air intake side (R- right)
View from inspection sideView from inspection side
1200VE / VW EKO 3.0
AVS 315
[kW]
0,408/2,71
0,415/2,81
4,84/15,69 0,84 /5,69
2016; 2018
indoors
AIR HANDLING UNITS
~2, 400
4,0
~1, 230
3400
3400
75%
PRV V2
M5/F7
50
7040
192
34
Temperature eciency (balanced mass ow):
LWA, dB(A)
V [m3/h]
1200V EKO 3.0
Supply7863747170696455
Extract6757635652535137
Surrounding5747544947494636
Measured at 1351 m3/h, 181 Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
The company reserves the right to make changes of technical data without prior notice
Extract air = 20°C/60%RH
Outdoor air = -20°C
11 7
666
RIRS V EKO
RIRS 1900V EKO 3.0
Supply air
Δ Pstat [Pa]Δ Pstat [Pa]
Exhaust air
AIR HANDLING UNITS
Specic fan power
Δ Pstat [Pa]
total power for supply & exhaust fans kW
SFP=
Temperature eciency
η [%]
air ow m3/h
x 3600
Performance
Power consumption
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
V [m3/h]
V [l/s]
P [W]
P [W]
RIRS 1900VL EKO 3.0
Air intake side (L- left)
Extract airExhaust airOutdoor airSupply air
Article No.Version
GAGRIRS1712_0011B1900VEL EKO 3.0
GAGRIRS1713_0012A 1900VWL EKO 3.0
GAGRIRS1708_0009B1900VER EKO 3.0
GAGRIRS1711_0010A 1900VWR EKO 3.0
Water heater (optional) VW ver.
Electrical heater VE ver.phase/voltage [50Hz/VAC]
EC fansphase/voltage [50Hz/VAC]
exhaustpower/current[kW/A]
supplypower/current[kW/A]
Thermal eciency up to*
Max power consumption VE / VW[kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALgrey
Weight (net, without packing)[kg]
Comply with ERP
Operation
Housing protection classIP
Left-hand maintenace version with integrated electrical heater
Left-hand maintenace version prepared
for optional water heater
Right-hand maintenace version with
integrated electrical heater
Right-hand maintenace version prepared
for optional water heater
fan speed[min-1]
fan speed[min-1]
* Calculated wet eciency.
RIRS 1900VR EKO 3.0
Air intake side (R- right)
View from inspection sideView from inspection side
1900VE / VW EKO 3.0
AVS 315
[kW]
9,96/19,37 0,96/6,37
~3, 400
~1, 230
0,47/3,1
2540
0,47/3,1
2540
PRV V2
M5/F7
7040
180178
2016; 2018
indoors
9,0
75%
50
34
11 8
Temperature eciency (balanced mass ow):
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
V [m3/h]
1900V EKO 3.0
Supply8058767172717062
Extract6956676054585748
Surrounding6044575149535245
Measured at 1830 m3/h, 101 Pa
The company reserves the right to make changes of technical data without prior notice
Thermal eciency up to*
Max power consumption VE / VW[kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALgrey
Weight (net, without packing)[kg]
Comply with ERP
Operation
Housing protection classIP
2500VE / VW EKO 3.0
[kW]
* Calculated wet eciency.
**Under covered area.
V [l/s]
Temperature eciency (balanced mass ow):
2500V EKO 3.0
Supply7861687273706462
Extract6759626357524843
Surrounding6245545952524946
Measured at 2355 m3/h, 214 Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
LWA, dB(A)
x 3600
V [m3/h]
V [m3/h]
The company reserves the right to make changes of technical data without prior notice
Thermal eciency up to*
Max power consumption VE / VW[kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALgrey
Weight (net, without packing)[kg]
Comply with ERP
Operation
Housing protection classIP
* Calculated wet eciency.
**Under covered area.
[kW]
14,72/29,35 2,72/12,05
380,0370,0
indoors/outdoors**
SVS-V
~3, 400
12
~1, 230
1,35/6
2390
1,33/5,7
2390
75%
PRV V2
M5/F7
50
7040
2016; 2018
34
120
Temperature eciency (balanced mass ow):
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
V [m3/h]
3500V EKO 3.0
Supply8260747576757368
Extract7258706660575143
Surrounding6455585957534945
Measured at 3728 m3/h, 242 Pa
The company reserves the right to make changes of technical data without prior notice
Thermal eciency up to*
Max power consumption VE / VW[kW/A]
Control board
Filter classexhaust/supply
Housing insulation, mineral wool[mm]
ColourRALgrey
Weight (net, without packing)[kg]
Comply with ERP
Operation
Housing protection classIP
* Calculated wet eciency.
**Under covered area.
V [m3/h]
V [l/s]
View from inspection side
Extract airExhaust air
fan speed[min-1]
fan speed[min-1]
View from inspection side
Outdoor air
Integrated electrical heater and 0-10
rotor
Optional water heater and 0-10 rotor control
Supply air
5500VE / VW EKO 3.0
SVS-V
[kW]
21,84/32,55 3,84/6,55
580,0565,0
indoors/outdoors**
~3, 400
18
~3, 400
1,9/3,1
2180
1,9/3,1
2180
75%
PRV V2
M5/F7
50
7040
2016; 2018
34
Temperature eciency (balanced mass ow):
LWA, dB(A)
V [m3/h]
5500V EKO 3.0
Supply8768808182787774
Extract7563697266635855
Surrounding7458666968655154
Measured at 5652 m3/h, 246Pa
Lwa total,
dB(A)
125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
The company reserves the right to make changes of technical data without prior notice
IV - exhaust air fan
PV - supply air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air lter (class F7)
IF - extract air lter (class M5)
TJ - temperature sensor for supply air
TL - temperature sensor for fresh air
TE - temperature sensor for exhaust air
DTJ - humidity + temperature sensor for extract air
EKA NV PH - optional fresh air pre-heater
AVA - optionally supplied water cooler
122
AVA
TE
PS2
The company reserves the right to make changes of technical data without prior notice
DTJ
PS1 - supply air dierential pressure switch
PS2 - extract air dierential pressure switch
DTJ - humidity + temperature sensor
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air lter (class F7)
IF - extract air lter (class M5)
TJ - temperature sensor for supply air
TL - temperature sensor for fresh air
TE - temperature sensor for exhaust air
EKA NV PH - optional fresh air pre-heater
AVA - optionally supplied water cooler
PS1 - supply air dierential pressure switch
PS2 - extract air dierential pressure switch
DTJ - humidity + temperature sensor for extract air
IV - exhaust air fan
PV - supply air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air lter (class F7)
I F - extract air lter (class M5)
TJ - temperature sensor for supply air
TL - temperature sensor for fresh air
TE - temperature sensor for exhaust air
EKS NV PH - optional fresh air pre-heater
RIRS 400VW EKO 3.0 / RIRS 700VW EKO 3.0 (vertical) versions with water heater
AVA
AIR HANDLING UNITS
TE
AVS - optionally supplied water heater
DTJ 100.1
The company reserves the right to make changes of technical data without prior notice
AVA - optionally supplied water cooler
EKA NV PH - optional fresh air pre-heater
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air lter (class F7)
IF - extract air lter (class M5)
TJ - supply air temperature sensor
TL - fresh air temperature sensor
M1 - optionally supplied mixing valve and motor
T1 - antifrost thermostat
TV - antifrost sensor
TE - temperature sensor for exhaust air
DTJ - humidity + temperature sensor for extract air
M6 - optionally supplied mixing valve and motor
M4 - water heater circulation pump
123
RIRS V EKO
RIRS 1200VW EKO 3.0 / RIRS 1900VW EKO 3.0 (vertical) versions with water heater
TE
AIR HANDLING UNITS
PS2
DTJ 100.1
PS1
AVA
AVS
PS1 - supply air dierential pressure switch
PS2 - extract air dierential pressure switch
AVS - optionally supplied water heater
AVA - optionally supplied water cooler
EKA NV PH - optional fresh air pre-heater
DTJ - humidity + temperature sensor
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air lter (class F7)
IF - extract air lter (class M5)
TJ - air temperature sensor
TL - air temperature sensor
M6 - optionally supplied mixing valve and motor
M4 - water heater circulation pump
T1 - antifrost thermostat
TV - supplied antifrost sensor
TE - temperature sensor for exhaust air
124
RIRS 2500VW EKO 3.0 / RIRS 3500VW EKO 3.0 / RIRS 5500VW EKO 3.0
(vertical) versions with optional water heater
SVS
EKS NV
PH
SVS - optionally supplied water heater
TE
PS2
The company reserves the right to make changes of technical data without prior notice
DTJ
PS1
PS1 - supply air dierential pressure switch
PS2 - extract air dierential pressure switch
DTJ - humidity + temperature sensor
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air lter (class F7)
IF - extract air lter (class M5)
TJ - air temperature sensor
TL - air temperature sensor
TE - temperature sensor for exhaust air
M6 - optionally supplied mixing valve and motor
M4 - water heater circulation pump
T1 - antifrost thermostat
TV - supplied antifrost sensor
EKS NV PH - optional fresh air pre-heater
FUNCTIONS
Description of the functions
Functions
Date and time settings
4 speeds for easy and user-friendly control (“Stop” – the unit is stopped; “Low”, medium”, and “High”. Service menu allows adjusting each
BOOST function (Fans operate at highest speed)
Comfortable air temperature function
User and service control levels
CO2 level indication and reduction function
Relative humidity (RH) level indication and reduction function
Software and conguration update possibility
Supply air temperature control according to the extract air sensor