SAJ Suntrio Plus 17K, Suntrio Plus 33K, Suntrio Plus 40K, Suntrio Plus 60K, Suntrio Plus 50K User Manual

...
User Manual
SAJ Solar Inverter
Suntrio Plus Series
www.saj-electric.com
Suntrio Plus Series
Preface
Thank you for choosing a SAJ solar inverter. We are pleased to provide you with first-class products and exceptional service.
This manual includes information for installation, operation, maintenance, trouble shooting and safety. Please follow the instructions of this manual so that we can ensure delivery of our professional guidance and wholehearted service.
Customer-orientation is forever our commitment. We hope this document proves to be of great assistance in your journey for a cleaner and greener world.
Please check for the latest version at www.saj-electric.com
Guangzhou Sanjing Electric Co., Ltd.
Building e-Energy management solution provider
Suntrio Plus Series
Content
Preface..................................................................................................... - 1 -
Content.................................................................................................... - 2 -
Chapter 1 Safety Precautions................................................................- 4 -
1.1 Scope of Application..................................................................................- 4 -
1.2 Safety Instructions......................................................................................- 4 -
1.3 Target Group...............................................................................................- 5 -
Chapter 2 Preparation...........................................................................- 6 -
2.1 Safety Instructions......................................................................................- 6 -
2.2 Explanations of Symbols........................................................................... - 8 -
Chapter 3 Product Information...........................................................- 10 -
3.1 Application Scope of Products................................................................ - 10 -
3.2 Specification for Product Model..............................................................- 11 -
3.3 Overview of products...............................................................................- 11 -
3.4 Datasheet.................................................................................................. - 13 -
Chapter 4 Instructions for installation................................................ - 17 -
4.1 Safety Instructions....................................................................................- 17 -
4.2 Pre-installation Check..............................................................................- 17 -
4.3 The Determination of the Installation Method and Position.................. - 18 -
4.4 Mounting Procedure.................................................................................- 20 -
Chapter 5 Electrical Connection.........................................................- 24 -
5.1 Safety Instruction for Hot-line Job..........................................................- 24 -
5.2 Specifications for Electrical Interface.....................................................- 25 -
5.3 AC Side Connection.................................................................................- 25 -
5.4 DC Side Connection................................................................................ - 27 -
5.5 Communication Connection.................................................................... - 30 -
Suntrio Plus Series
Chapter 6 Debugging Instructions......................................................- 32 -
6.1 Introduction of Human-computer Interface............................................ - 32 -
6.2 First Run Setup.........................................................................................- 33 -
6.3 Monitoring Operation.............................................................................. - 42 -
Chapter 7 Fault Code and Troubleshooting........................................- 43 -
Chapter 8 Recycling and Disposal..................................................... - 46 -
Chapter 9 Guarantee Service..............................................................- 47 -
Chapter 10 Contact SAJ..................................................................... - 48 -
SAJ Warranty Policy.......................................................................... - 49 -
Warranty Card........................................................................................- 53 -
Suntrio Plus Series
Chapter 1 Safety Precautions
1.1 Scope of Application
This User Manual describes instructions and detailed procedures for installing,
operating, maintaining, and troubleshooting of the following SAJ grid-tied
inverters:
Suntrio Plus 12K; Suntrio Plus 15K; Suntrio Plus 17K; Suntrio Plus 20K;
Suntrio Plus 25K; Suntrio Plus 33K; Suntrio Plus 40K; Suntrio Plus 50K
Suntrio Plus 60K
Please keep this manual all time available in case of emergency.
1.2 Safety Instructions
DANGER
· DANGER indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
WARNING
· WARNING indicates a hazardous situation which, if not avoided, can result in death or serious injury or moderate injury.
CAUTION
· CAUTION indicates a hazardous condition which, if not avoided, can result in minor or
moderate injury.
NOTICE
· NOTICE indicates a situation that can result in potential damage, if not avoided.
Suntrio Plus Series
1.3 Target Group
Only qualified electricians who have read and fully understood all safety
regulations contained in this manual can install, maintain and repair the inverter.
Operators must be aware of the high-voltage device.
Suntrio Plus Series
Chapter 2 Preparation
2.1 Safety Instructions
DANGER
· Dangerous due to electrical shock and high voltage.
· Do not touch the operating component of the inverter, or it might result in burning or death.
· To prevent risk of electric shock during installation and maintenance, please make sure that all AC and DC terminals are plugged out.
· Do not touch the surface of the inverter while the housing is wet, or it might lead to electrical shock.
· Do not stay close to the inverter while there are severe weather conditions including storm, lighting, etc.
· Before opening the housing, the SAJ inverter must be disconnected from the grid and PV generator; you must wait for at least five minutes to let the energy storage capacitors fully be discharged after disconnecting from power source.
WARNING
·The installation,service, recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations.
·Any unauthorized actions including modification of product functionality of any form may cause lethal hazard to the operator, third parties, the units or their property. SAJ is not responsible for the loss and these warranty claims.
·The SAJ inverter must only be operated with PV generator. Do not connect any other source of energy to the SAJ inverter.
·Be sure that the PV generator and inverter are well grounded in order to protect safety of people’s life and property.
CAUTION
·The PV inverter will become hot during operation. Please do not touch the heat sink or peripheral surface during or shortly after operation.
·Risk of damage due to improper modifications.
Suntrio Plus Series
NOTICE
·Public utility only
·The PV inverter is designed to feed AC power directly to the public utility power grid; do not connect AC output of the inverter to any private AC equipment.
Suntrio Plus Series
2.2 Explanations of Symbols
Symbol Description
Dangerous electrical voltage
This device is directly connected to public grid, thus all work to the inverter shall only be carried out by qualified personnel.
DANGER to life due to high electrical voltage!
There might be residual currents in inverter because of large capacitors. Wait for 5 MINUTES before you remove the front lid.
NOTICE, danger!
This is directly connected with electricity generators and public grid.
Danger of hot surface
The components inside the inverter will release a lot of heat during operation. Do not touch metal plate housing during operating.
An error has occurred
Please go to Chapter 9 “Troubleshooting” to remedy the error.
This device SHALL NOT be disposed of as residential waste
Please go to Chapter 8 “Recycling and Disposal” for proper treatments.
Without Transformer
This inverter does not use transformer for the isolation function.
Security Certificate
The inverter complies with
European product safety instructions.
CE Mark
Equipment with the CE mark fulfills the basic requirements of the Guideline Governing Low-Voltage and Electro-magnetic Compatibility.
SAA Mark
The inverter complies with the requirement of Equipment and Product Safety Act in Australia.
CQC Mark
The inverter complies with the safety instructions from China's Quality Center.
Suntrio Plus Series
No unauthorized operations or modifications
Any unauthorized operations or modifications are strictly forbidden, if any defect or damage (device/person) occurs, SAJ shall not take any responsibility for it.
Suntrio Plus Series
-10-
Chapter 3 Product Information
3.1 Application Scope of Products
Suntrio Plus series products are grid-tied three phase inverters without
transformers, and the inverters are important components of grid-tied solar power
systems.
The Suntrio Plus inverters change the DC generated by solar panels into AC which
is in accordance with the requirements of public grid, and send the AC into the grid,
Table 3.1 shows the structural diagram of the typical application system of Suntrio
Plus inverters.
Name Description Remarks
A Solar panels
Monocrystalline or polycrystalline silicon, and thin-film PV modules with II protection and need no ground connection
B Inverters Suntrio Plus 12K/15K/17K//20K/25K/33K/40K/50K/60K
C
Metering
equipment
Standard metering tool for measuring the output electric power of inverters
D Power grid
TTTN-CTN-STN-C-S
Table 3.1 Systematic Configuration Diagram
Suntrio Plus Series
-11-
3.2 Specification for Product Model
Suntrio Plus XK
1
Suntrio Plus represents for product name.
XK represents rated power XkW of inverter, for example 12K means 12kW.
3.3 Overview of products
Figure 3.2 Overview of Suntrio Plus 12K/15K/17K/20K
Figure 3.3 Overview of Suntrio Plus 25K/33K
Suntrio Plus Series
-12-
Figure 3.4 Overview of Suntrio Plus 40K/50K/60K
Suntrio Plus Series
-13-
3.4 Datasheet
Sunttrio Plus 12K/15K/17K/20K
Type
Suntrio Plus
12K
Suntrio Plus
15K
Suntrio Plus
17K
Suntrio Plus
20K
Input (DC)
Max. DC Power [W]
14520 18150 20570 24200
Max. DC Voltage [V]
1000
MPPT Voltage Range [V]
180-900
Nominal DC Voltage [V]
600
Start Voltage[V]
200
Min. DC Voltage[V]
180
Max. DC Input Current PV1 / PV2 [A]
22/11 22/22 22/22 22/22
Number of MPPT 2
Number of DC Connection Sets per MPPT
2/1 2/2 2/2 2/2
DC Switch Integrated
Output (AC)
Rated AC Power [W] (@230V,50Hz)
12000 15000 17000 20000
Max. AC Power [VA]
13200 16500 18700 22000
Rated AC Current[A]
17.4 21.7 24.6 29.0
Max. AC Current [A]
20.0 25.0 28.3 33.0
Nominal AC voltage/ range 3/N/PE, 220/380V,230/400V,240/415V;180V-280V/312V-485V
Grid frequency/ range 50Hz,60Hz /44Hz-55Hz,54Hz-65Hz
Power factor,adjustable 0.8 leading~0.8lagging
Total Harmonic Distortion (THDi)
< 3% (at nominal power)
Feed-in Grid
3L+N+PE
Efficiency
Max. Efficiency
98.3% 98.4% 98.5% 98.5%
Euro Efficiency (at 600Vdc)
98.0% 98.1% 98.2% 98.2%
MPPT Accuracy >99.5%
Protection
Internal Over-voltage Protection
Integrated
DC Insulation Monitoring Integrated
DCI Monitoring Integrated
GFCI Monitoring Integrated
Grid Monitoring Integrated
AC Short Circuit Current Protection
Integrated
Thermal Protection Integrated
Suntrio Plus Series
-14-
AC Surge Protection
Integrated),Ⅱ(Optional
Low Voltage Ride Through Integrated
String Current Monitoring Integrated
Anti-PID Module Optional
DC Fuse Optional
DC Surge Protection
Optional
Anti-island protection monitoring
AFD
Interface
DC Connection MC4/H4
AC Connection Terminal Block
LCD Display
3.5 inch Graphic LCD Display
Display Language English
Communication Port 2*RS485+1*RS232
Communication Mode Wi-Fi/GPRS/Ethernet (Optional)
General Data
Topology Transformerless
Consumption at Night [W] <0.6
Consumption at Standby [W] <10
Operating Temperature Range -25°C to +60°C(45°C to 60°C with derating)
Cooling Method
Intelligent Fan
Ambient Humidity 0 to 100% Non-condensing
Altitude 3000m (>2000m power derating)
Noise [dBA]
<35
Ingress Protection IP65 (Indoor & Outdoor Installation)
Mounting Rear Panel
Dimensions (H*W*D) [mm]
640*450*232
NetWeight[kg]
29 33
Standard Warranty [Year] 5 (standard)/10/15/20/25 (Optional)
Certificates
IEC62109-1/2, IEC61000-6-2/3, IEC61683, IEC60068-2, IEC62116, IEC61727, PEA/MEA, NRS 097-2-1, UTE-C-15-712-1, VDE0126-1-1/A1, VDE-AR-N 4105, AS4777.2, AS4777.3, C-TICK, CQC NB/T 32004, G83-2,NBR 16149, NBR 16150,TF 3.2.1
Suntrio Plus Series
-15-
Sunttrio Plus 25K/33K/40K/50K/60K
Type
Suntrio Plus
25K
Suntrio Plus
33K
Suntrio Plus
40K
Suntrio Plus
50K
Suntrio Plus
60K
Input (DC)
Max. DC Power [W]
30300 36300 48400 60500 72000
Max. DC Voltage [V]
1000
MPPT Voltage Range [V]
180-900 280-900
Nominal DC Voltage [V]
600
Start Voltage[V]
200 300
Min. DC Voltage[V]
180 250
Max. DC Input Current PV1 / PV2 [A]
22/22/22 40/30/30 40/40/40
Number of MPPT 3
Number of DC Connection Sets per MPPT
2/2/2 4/3/3 4/4/4
DC Switch Integrated
Output (AC)
Rated AC Power [W] (@230V,50Hz)
25000 30000 40000 50000 60000
Max. AC Power [VA]
27500 33000 44000 55000 60000
Rated AC Current[A]
36.2 43.5 58.0 72.5 87.0
Max. AC Current [A]
42.0 50.0 65.0 80.0 90.0
Nominal AC voltage/ range 3/N/PE, 220/380V,230/400V,240/415V;180V-280V/312V-485V
Grid frequency/ range 50Hz,60Hz /44Hz-55Hz,54Hz-65Hz
Power factor,adjustable 0.8 leading~0.8lagging
Total Harmonic Distortion (THDi)
< 3% (at nominal power)
Feed-in Grid
3L+N+PE
Efficiency
Max. Efficiency
98.6% 98.8% 98.8% 98.8% 98.9%
Euro Efficiency (at 600Vdc)
98.4% 98.5% 98.5% 98.5% 98.6%
MPPT Accuracy >99.5%
Protection
Internal Over-voltage Protection
Integrated
DC Insulation Monitoring Integrated
DCI Monitoring Integrated
GFCI Monitoring Integrated
Grid Monitoring Integrated
AC Short Circuit Current Protection
Integrated
Thermal Protection Integrated
AC Surge Protection
Integrated
Low Voltage Ride Through Integrated
Suntrio Plus Series
-16-
String Current Monitoring Integrated
Anti-PID Module Optional
DC Fuse Optional
DC Surge Protection
Integrated
Anti-island protection monitoring
AFD
Interface
DC Connection MC4/H4
AC Connection Terminal Block
LCD Display
3.5 inch Graphic LCD Display
Display Language English
Communication Port 2*RS485+1*RS232
Communication Mode Wi-Fi/GPRS/Ethernet (Optional)
General Data
Topology Transformerless
Consumption at Night [W] <0.6
Consumption at Standby [W] <10
Operating Temperature Range -25°C to +60°C(45°C to 60°C with derating)
Cooling Method
Intelligent Fan
Ambient Humidity 0 to 100% Non-condensing
Altitude 3000m (>2000m power derating)
Noise [dBA]
<35
Ingress Protection IP65 (Indoor & Outdoor Installation)
Mounting Rear Panel
Dimensions (H*W*D) [mm]
700*530*260 800*550*280
NetWeight[kg]
48 68
Standard Warranty [Year] 5 (standard)/10/15/20/25 (Optional)
Certificates
IEC62109-1/2, IEC61000-6-2/3, IEC61683, IEC60068-2, IEC62116, IEC61727, PEA/MEA, NRS 097-2-1, UTE-C-15-712-1, VDE0126-1-1/A1, VDE-AR-N 4105, AS4777.2, AS4777.3, C-TICK, CQC NB/T 32004, G83-2,NBR 16149, NBR 16150,TF 3.2.1
Loading...
+ 39 hidden pages