Safran MA SIGMA, MA SIGMA WR, MA SIGMA iCLASS, MA SIGMA iClass WR, MA SIGMA Multi Quick User Manual

...
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
MorphoAccess
®
SIGMA Series
Quick User Guide
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
1
Table of Contents
2014_0000000530-V6
Color
Step
Content
One
Overview
Two
Wiring
Three
Communication
Four
ACP or SDAC
Five
Administration
Six
Software
Seven
Enrollment
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
2
MorphoAccess® SIGMA Overview
The MorphoAccess®SIGMA terminal has a
simple and ergonomic man-machine interface
designed for access control and Time & Attendance, with fingerprint recognition, contactless card authentication and PIN authentication options.
USB port (for
configuration and
settings with a
USB mass
storage key)
Step one : overview
USB host port
WR* product comes with a
sensor protection
cap (not displayed here)
Optional Wi-Fi
USB adaptor
(plugged at the back
of the terminal)
5“ WVGA
touchscreen LCD
Optical biometrical sensor
VGA Camera
Speaker
Microphone
HID® iCLASS™ 13,56MHz (SIGMA … ICLASS)
Or MIFAREDESFire 13,56MHz (SIGMA .. MULTI)
Or HID® Prox ® 125kHz (SIGMA .. PROX)
Optional Contactless Card reader.
Specific logo on cover when available
Status LED
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
3
QTY
ITEM
1
MorphoAccess
®
SIGMA terminal
1
Micro SD card installed
in the terminal
1
Wall Mount Plate
1
Battery
1
POE module
1
Protection Accessory (WR* product only)
1
Flat screw driver 0.4 x 2.0
1
Quick Installation Guide
1
WEEE notice
Indoor & Weather Resistant (WR) Checklist
*WR : Weather Resistant
Step one : overview
Electronic documentation is provided in Adobe® Acrobat® format (PDF). Adobe® Acrobat® Reader is available at http://www.adobe.com.
Product packaging checklist:
Micro SD card must be installed in the
terminal at start up (storage area for internal
database and terminal logs)
Micro SD card replacement:
Class 10 or higher, 1GB min, 32GB maxFormatted by the terminal. Windows® PC
may damage the content of the card and
make it inoperative.
Use only Brand Name cards. No name
card may have lower performances or lower life time.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
4
MorphoAccess® SIGMA Series
Step one : overview
Product
designation
Biometrics
(Fingerprint)
iCLASS
®
MIFARE
®
DESFire
®
NFC
Prox
®
Water
Resistant (*)
MA SIGMA
MA SIGMA WR
MA SIGMA
iCLASS
MA SIGMA
iClass WR
MA SIGMA Multi
MA SIGMA Multi WR
MA SIGMA Prox
MA SIGMA Prox WR
The MorphoAccess® SIGMA Series contains the following product variants:
Contactless Smart
card reader
MA stands for MorphoAccess®and WR stands for Water Resistant
(*) WR units must be installed according to installation guidelines on Quick Installation Guide
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
5
MorphoAccess® SIGMA terminal implementation
ACCESS CONTROL
SYSTEM
(*) OR EQUIVALENT
NON SECURED
AREA
ACCESS
CONTROLLER
TCP/IP, Wiegand, Dataclock, RS485 or RS422
ELECTRIC
LATCH (*)
SECURED
AREA
Dry Contact
MorphoAccess
®
Sigma Terminal
Dry Contact
ALARM
Step one : overview
The MorphoAccess®SIGMA Series terminal
Its role is to process the access request from the user. It performs access right checks using one-to-many biometric identification or one-to-one biometric verification, and/or RF card authentication, and/or PIN check.
A Door Electric Latch or equivalent such Deadbolt, Door Strike or Magnetic Lock (3rd party product)
The Access Controller sends a command to activate the latch if the access is granted (i.e. if the individual's User ID is listed in the Controller White List). Control of the latch is made through a dry contact..
An Alarm (3rd party product)
The MorphoAccess®terminal sends a message to the Access Controller, to activate the Alarm as soon as a malicious activity such as tamper or pulling, is detected.
To secure an access, Morpho recommends installing the MorphoAccess®SIGMA Series terminal as a part of a typical Access Control system, this consists of the components described below.
An Access Controller (3rd party product)
The MorphoAccess®terminal interfaces with an Access Controller
(using TCP/IP, Wiegand, Data Clock or RS485 protocol):
After user’s access rights checks, the MorphoAccess
®
terminal sends the result to the Access Controller (this message contains at least the User ID)
The Access Controller performs additional checks, and returns the
final decision (access granted/denied) to the MorphoAccess
®
terminal (which displays the result to the user), and to the door controller which opens the door (if the access has been granted).
A
A
B
B
D
D
C
C
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
6
MorphoAccess® SIGMA Access Control Modes
Step one : overview
(1) or the user enter their Identifier on the keypad, or a Wiegand frame is received from an external device
(2) stored on the contactless card or in the user record in the terminal’s local database
(3) There is no fingerprint image stored in the terminal, but only points of interest (minutiae) of each fingerprint
Identification
Authentication
Multifactor
Proxy
Access
control
a
pplication
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Remote application
that controls the
terminal through network commands
Access control
triggering
event A
user places a
finger on the
biometric sensor.
A user places
a
contactless
card in
front of
the reader (1)
Both
Identification
and Authentication
triggers are enabled.
Triggering events are selected
by the
remote application
Biometric check (if enabled)
The user’s captured
fingerprint template is matched against all fingerprint
templates in the
terminal database (3)
The user’s captured
fingerprint templated is
matched against
his reference
fingerprint templates
(2)
As per Identification or Authentication, depending on the triggering event
Selected
by the
remote application
Decision
to
display
result
signal to user
By Identification standalone application
By Authentication standalone application
By
running
s
tandalone
application
By remote application
The terminal can be configured in one of the modes described in the table below
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
7
Deployment Environments
Step one : overview
General precautions
Do not expose the terminal to extreme temperatures. When the environment is very dry, avoid synthetic carpeting near the MorphoAccess® SIGMA terminal, to
reduce the risk of unwanted electrostatic discharge.
Areas containing combustibles
Do not install the terminal in the vicinity of gas stations or any other installation containing flammable or
combustible gases or materials. The terminal is not designed to be intrinsically safe.
The terminal should be installed in controlled lighting conditions
Avoid biometric sensor exposure to a blinking light Avoid direct exposure of the biometric sensor to sunlight or to UV lights.
Operating temperature
-
20°to + 60 °C (- 4°to 140°F)
Operating
humidity
10 % < RH < 80 % (non condensing)
Storage
temperature
-
25°to + 70 °C (-13° to 158°F)
Storage
humidity
5% < RH < 95 %
IP code
IP65 rated for WR(*) products (once wall
-mounted)
(*) WR units must be installed according to installation guidelines on Quick Installation Guide
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
8
C
Wiring Overview
Step two : wiring
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
Power supply from electrical source shall be switched off before starting the installation. Before proceeding, make sure that the person in charge of installation and connections, is
properly connected to earth, in order to prevent Electrostatic Discharges (ESD).
1
6
2
5
4
3
Power Supply +12V
Power Ground
Tamper switch 2 Tamper switch 1
Digital Ground
Digital Ground
1
6
2
5
4
3
Wiegand IN 0 Wiegand IN 1
Wiegand OUT 0 Wiegand OUT 1
Wiegand LED 1 Wiegand LED 2
1
6
2
5
4
3
Digital Input 0 Digital Input 1
Digital Input 2
Digital Output 0
Digital Output 1
Digital Output 2
1
6
2
5
4
3
Relay_NO
RS422 RX-
RS422/485 TX+
RS422/485 TX-
Battery
Reset button
A
A
B
B
C
RJ-45
USB
µSD
D
D
Relay_COM
RS422 RX+
Connection: Insert cable in the round hole of the block connector. Disconnection: Insert flat screw driver (0.4x2.0max) in rectangular hole and pull the wire.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
9
Power Wiring
Step two : wiring
External Power Supply: 12-24 Volts (regulated and filtered) 1 Amp min @12V,
CEE/EEC EN60950 standard compliant. A12 Volts power supply compliant with SIA's
Wiegand standard will also be suitable. If sharing power between devices, each unit must receive 1A (e.g. two units would require a 12vDC, 2A supply)
WARNING: Under powering may cause memory and data corruption; over powering may cause hardware damage. Both of these situations will void the
warranty
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is recommended.
1
A
2 3
Power Supply +12V
Power Ground
Inversion of +12V and GND will damage the product.
B C D
Gauge
AWG
Diameter
(mm)
Maximum drop voltage (V)
at 1m at 5m at 10m
20 0.81 0.03 0.17 0.33 22 0.64 0.05 0.26 0.53 24 0.51 0.08 0.42 0.84
Morpho recommends using a gauge AWG20 for 12V power supply. The voltage measured on the product block connector of the terminal must be equal
to 12V-24V (-15% / +10%). The table below, shows the maximum voltage drop between the power source and the
terminal, depending on the length of the cable.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
10
Power Over Ethernet & Battery
Step two : wiring
USB
1
2
6
Power Over Ethernet (POE): power can be provided through RJ-45 connector using a PSE (Power Sourcing Equipment) IEEE 802.3af or IEEE802.3at type 1 compliant.
This feature requires a specific electronic card plugged at the rear of the product. Warning : after use, the temperature of the POE module may be high: after power cut off,
wait 5mn before working on connectors area.
POE
RJ-45
Battery
Battery
Installation : the engraved side, the positive side (+), must face upwards.
protects the date and time in case of power failure or switch off
lifetime is limited : at least 350 hours at 25°C, when power is off:
must be changed after a long power cut or after several shorter power cuts.
Remove and store the battery if the terminal will be unpowered for a long period of time
PoE Injector Specs
Output Voltage: -48VDCOutput Current: 0.32APower: 15.36W
Reset Button : performs a hardware reset of the terminal (one power down, power up cycle). No data is lost and the settings are kept if the battery is installed and has charge.
Reset Button
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
11
RS-485 Communication
Step
three : communications
1
D
2
4
3
A maximum of 31 devices may be installed on the same line. The maximum total cable length is 4000 ft. (1200m). The cable must be dedicated to this installation and not used for any other purpose
Choose a RS-232 to RS-485 converter that supports Sense Data to switch from Send to Receive mode.
RS-232 from the
Com Port
RS-232 to RS-485 converter
RS-485 to 1200m (4000ft)
RS485 TX+
RS485 TX-
For RS-485 installations, the cable should be run in a daisy-chain configuration (i.e. converter > position 1 > position 2 > position 3, etc.).
Use CAT-5 UTP (or better) cable (shielded recommended) with a impedance of 120 . AWG 24 should be the minimum wire gauge used.
Choose one twisted pair of conductors to use for RS-485 TDA/TX+ (D-5 wire) and RS-485 TDB/TX- (D-6 wire). Another conductor should be used for Signal Ground (A-5 or A-6 wires) .
1
6
2
5
4
3
GND GND
A B C
6
5
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
12
RS-422 Communication
Step
three : communications
1
D
2
4
3
RS422 TX+
RS422 TX-
1
6
2
5
4
3
GND GND
A B C
6
5
RS422 RX-
RS422 RX+
The maximum total cable length is 4000 ft. (1200m).
The cable must be dedicated to this installation and not used for any other purpose
For RS-422 installations, the cable should be run in a point to point configuration (i.e. PC > converter > terminal)
Use CAT-5 UTP (or better) cable (shielded recommended) with a impedance of 120 . AWG 24 should be the minimum wire gauge used.
Choose one twisted pair of conductors to use for RS-422 TDA/TX+ (D­5 wire) and RS-422 TDB/TX- (D-6 wire).
Choose one twisted pair of conductors to use for RS-422 RDA/RX- (D­3 wire) and RS-422 RDB/TX+ (D-4 wire).
Another conductor should be used for Signal Ground (A-5 or A-6 wires).
RS-232 from the
Com Port
RS-232 to RS­422 converter
RS-422 to 1200m (4000ft)
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
13
Ethernet and Wireless LAN
RJ-45 Ethernet connection (recommended)
Ethernet connection to the terminal is made through a
standard RJ-45 connector on the back of the terminal.
Use a category 5 shielding cable (120 Ohms) or better. It is
strongly recommended to insert a repeater unit every 90m.
By default, MorphoAccess® SIGMA Series terminal is
configured in Static IP mode.
Terminal Block Ethernet connection
Extreme care must be taken while connecting Ethernet
wire to the block board since low quality connection may
strongly impact Ethernet signal sensibility.
Connect Rx+ and Rx- with the same twisted-pair wire (and to
do the same with Tx+/Tx- and the other twisted-pair wire).
Step
three : communications
Management
station
Wireless
WLAN option
This option is available only with Wi-Fi™ dongle (and adaptation cable) delivered by Morpho (kit
reference 293658530), and requires the terminal be powered by an external AC/DC 12V to 24V
power supply (the POE feature doesn’t provide enough power for the terminal and the dongle). Morpho Wi-Fi™ dongle supports 802.11b and 802.11g standards, WEP Open, WPA and WPA2.
The Wi-Fidongle shall not be exposed to temperatures exceeding 50°C (thermal dissipation). The Wi-Fi™ dongle shall be installed outside the product (separate area shall be reserved in the
wall).
2014_0000000530-V6
LAN Ethernet
IP address
Mode
Parameter Factory value
Static
Terminal IP address 192.168.1.10
Gateway IP address 192.168.1.254
Sub network mask 255.255.254.0
Host name
MAsigma
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
14
Wiegand Communication
Step
three : communications
Three-conductor wire (shielded recommended) is required for Data 0, Data 1, and WGND. Use 18-22 AWG cable in a homerun configuration from each unit to the Access Control Panel (ACP).
Connect WIEGAND_OUT0 (B-3 Wire) to ACP Data 0,Connect WIEGAND_OUT1 (B-4 Wire) to ACP Data 1,Connect WIEGAND_GND (A-5 or A-6 Wire) to ACP reader common (0vDC).
For 18 AWG, the maximum cable distance is 500 ft. (150m); for 20 AWG, the maximum is 300 ft. (90m); for
22 AWG, the maximum is 200 ft. (60m).
Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V TTL compatible.
1
6
2
5
4
3
Wiegand IN 0 Wiegand IN 1
Wiegand OUT 0 Wiegand OUT 1
Wiegand LED 1 Wiegand LED 2
1
6
2
5
4
3
GND GND
A B
Wiegand Out
Wiegand In
LED Out
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
15
Wiegand Communication (continued)
Step
three : communications
Example Format Information Type: Standard 26-bit
Alt Site Code and Fail Site Code Range: 0-255
Template ID Number Range: 1-65535 Extended ID Number Range: N/A ID Start Bit: 9 Length of ID: 16 Site Code Start bit: 1 Length of Site Code: 8 Start Bit length : 0
Important
By default, the Wiegand output format is not enabled. Wiegand output must be configured before connecting
to the ACP.
Note
On installation, the system administrator will be prompted to select either a pre-existing Wiegand frame format or create a custom format, and upload it to the
unit before the first use.
Data Clock
The Wiegand port also supports the Clock & Data protocol. The wiring is described below.
1
6
2
5
4
3
Wiegand IN 0 – Data IN
Wiegand IN 1 – Clock IN
Wiegand OUT 0 – Data OUT
Wiegand OUT 1 – Clock OUT
Wiegand LED 1
Wiegand LED 2
1
6
2
5
4
3
GND
GND
A B
Data Clock Out
Data Clock In
LED Out
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
16
SINGLE DOOR ACCESS CONTROL (SDAC)
Step four: ACP or SDAC
1
6
1
6
1
6
1
6
A
B C D
GPI1
GPO0
GPI0
GPO1
Relay_NO
Relay_Com
Deadbolt / Door strike
Power supply
Single Door Access Control (SDAC) wiring sample : with Push Button
Door contact
2
Power
supply
5
Push Button
4
2
Warning
Please check next page for important information about internal relay rating
If door contact is not used, GPI1 (C-2) and GPO1 (C-5) shall be connected together
Power supply from electrical source shall be switched off before starting the installation.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
17
Internal Relay Wiring (Normally open)
Inductive load management requires a parallel diode for a better contact lifetime.
Warning The internal relay is limited to a maximum current of 2A @ 30V. If the deadbolt / door strike draws
more than 2A, damage to the device may occur. If the deadbolt / door strike load exceeds 2A, an
external relay must be used.
The internal relay is designed for 100.000 cycles. If more cycles are needed, an external relay
driven by GPO must be used.
Power supply
VCC < 30V
Imax < 2A
Deadbolt / Door strike
Push Button
on other side of the door
Snubber Diode
1
D
2
Relay_NO
Relay_Com
A B C
(Sample)
Warning
This applies only for small
or stand-alone applications
where access control panels are not available.
In this mode it is strongly recommended to monitor the Tamper Detection of the device
Step four: ACP or SDAC
Relay mode can be
changed to “normally
close” instead of “normally closed” (default)
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
18
Local Administration - First Boot Assistant
The First Boot Assistant (FBA) helps the administrator to configure all the devices fundamental settings.
It is automatically launched at first terminal startup, but
can also be launched on demand, though administration
menu (i.e. to reinitialize terminal main settings)
Main settings managed by FBA
Date & Time Configuration: date & time, time zone Language Configuration: user interface language
selection, Trigger Event: select event(s) to be processed as an
access request by a user
Network Configuration: LAN or WLAN parameters
Recognition Mode: identification mode activation. Protocol Configuration: select communication
protocol : Bioscrypt 4G terminals, MA 500 and J Series (MA2G), or MorphoAccess SIGMA (MA5G)
Password Configuration: terminal administration password modification
First Boot Configuration Storage Type: select either temporary (i.e. for a short duration test, reboot
will restore previous values) or permanent storage
(applies to normal operation, new settings remains after reboot) of the setting modified by FBA.
The battery must be installed to prevent real time clock loss on power off or power failure
Step five: Administration
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
19
Frequently used icons
Local Administration – Using Touch Screen Menu
+ password (default: 12345)
For security reasons, it is highly recommended to change the devices default password to a custom password.
Exit or Go Home
Validation or confirmation
Cancel or
refuse
Back (and Cancel)
User
management
Security
Multimedia
management
Communication
settings
Information
about terminal
Terminal
settings
Restart USB key
management
Start/Stop
Step five: Administration
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
20
Administration with MorphoBioToolBox application
The MorphoAccess®SIGMA Series terminal can be configured using a dedicated (Windows) application : MorphoBioToolBox Please note that this application
has an embedded User Guide
(Help menu).
Terminal administration with MorphoBioToolBox (MBTB) application
Step five: Administration
North and South America : E-mail cscenter@morpho.com with your name, phone number, serial number of your MASIGMA and Please Send Link for MBTBin the
subject of your e-mail. A link to
download the software will be e­mailed to you. Other countries : please contact your sales representative.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
21
Administration with Embedded Web Server
The terminals embedded Web server enables easy configuration of the devices using a web browser on a Desktop PC, Laptop, Tablet or smart phone.
The connection to the embedded Webserver, through LAN or WLAN, requires the terminals IP address
(available with local administration)
and terminals password (same as local administration password specified in previous page).
By default, webserver is disabled, then if necessary it must be enabled using local administration before use.
Terminal administration with a standard web browser
Step five: Administration
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
22
Software for Terminal Remote Administration
MorphoAccess® SIGMA Series terminals are fully compatible with:
MorphoManager application(version 1.0 or later)
When Legacy Morpho mode enabled, the terminal is compatible with:
MEMS (version 7.3.1 or later), The limitations in Morpho Legacy mode are described in the following
document:
MorphoAccess® SIGMA Series Release Note - Legacy Morpho limitations
When Legacy L1 mode is enabled, the terminal is compatible with:
SecureAdmin (version v4.1.19.0.0.a10.0 or later), The limitations in L1 Legacy mode are described in the following document:
MorphoAccess® SIGMA Series Release Note - Legacy L1 limitations
Step six : Software
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
23
Local Enrolment Process on MorphoAccess® SIGMA
A new user can easily be added by using the administration menu of the MorphoAccess®SIGMA terminal. This “local enrolment” is recommended only for small or stand alone installations or testing purposes. For professional systems enrollment should be performed remotely with an
enrolment station, which is a PC with a dedicated application
such as MorphoManager.
This menu allows a user’s record to be added in the local
database, with the option of creating a user RF card, with the
user’s reference data.
Enrolment gathering user’s data listed below (depending on
features enabled in the terminal) :
User’s first name and last name User’s fingerprints (for biometric check) User’s administration rights (none, settings, database) User’s PIN (for PIN check) User’s duress fingerprint User’s access schedule and holiday schedule User’s dynamic message setting User’s record expiry date
User to include in white list or in VIP list User specific access rules definition
.
Step seven: capture basics
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
24
Fingerprint Capture Basics 1/3
Region of Interest Recommended Fingers Acquisition troubleshooting
The biometric sensor is designed to capture the most useful area
of the fingerprint,
which is usually at the centre of the finger tip, as shown on the figure above.
The sensor can capture any finger, but we recommend to :
use Fore finger / Index as 1stchoice
use middle finger as 2
nd
choice
use ring finger as alternative 2
nd
choice (3rdchoice)
avoid little finger (poor fingerprint)
avoid thumb (best accuracy but
ergonomically more difficult to use)
Step seven: capture basics
2
Fore Finger
Ring Finger
1
3
Fingerprint image too dark :
the finger is probably too moist and/or too dusty
too moist : dry the finger
too dusty: clean up the finger
Fingerprint image too light :
the finger is probably too cold and/or too dry
too cold : warm up the finger
too dry : moisten the finger (i.e. with
moistening pad) and /or warm it up.
Finger to capture
the fingerprint area must be free of
any occlusion (if not, select another finger to capture, such as the 2
nd
enrolled finger in case of authentication or identification)
do not press or tense finger to avoid
blood vessels constriction.
For handling large scale enrollments please contact your Morpho representative for training and services options
Middle Finger
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
25
Fingerprint Capture Basics 2/3
Ideal Finger Position
Finger Height
Finger Angle
IDEAL
POSITION
Incorrect Position:
Do not place the finger tip :
on the bottom of the sensor,
or in the middle of the sensor
Correct Position:
Align centre of finger tip with sensor centre
Incorrect Position:
Do not tilt the finger to the right or left side of the sensor
Correct Position:
The finger must be parallel to sensor sides
Step seven: capture basics
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
26
Fingerprint Capture Basics 3/3
Finger Inclination
IDEAL
POSITION
Finger rotation
IDEAL
POSITION
Ideal Finger Position
Incorrect Position:
Do not leave the finger in the air
Do not bend finger upward or downward
Correct Position:
Finger is parallel to sensor surface
Incorrect Position:
Do not roll finger
Correct Position:
Finger is parallel to surface sensor
Step seven: capture basics
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
27
Contactless Card Position – PIN input
This action is required once during the user enrolment process (generation / encoding of a user RF card), and at each authentication.
Place user’s RF card in front
of embedded contactless card reader which is located
behind the contactless logo.
Contactless Card Position Input PIN
The authentication process is initiated by the detection of a user card by the (optional) contactless card reader.
The terminal reads the user data stored in the card (at least the User ID), and starts the authentication process, as defined by the terminal settings
When defined by terminal settings, the user is required to enter his PIN code, once during enrolment process,
and at each authentication (in addition or instead of
biometric check). The PIN code is entered using a numeric keypad
displayed on the LCD touch screen.
Step seven: capture basics
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
28
Recommendations
The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal.
Repair and Accessories
Do not attempt to repair the MorphoAccess
®
SIGMA Series terminal yourself. The manufacturer cannot be held responsible for any
damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will void your warranty.
Only use the terminal with its original accessories. Attempts to use unapproved accessories with your terminal will void your warranty.
Standalone terminals (not connected to a network)
For terminals used in standalone mode, it is strongly recommended to regularly backup the local database, and at least after significant
changes in the database (add, remove or modification of user’s records), on a external support such a mass storage key
Micro SD Card
The micro SD card is linked to the terminal : it shall not be transferred from one product to another.
Date / Time synchronization
The MorphoAccess
®
SIGMA Series terminal clock has a +/- 10 ppm typical time deviation at +25°C (roughly +/- 1sec per day). At lower
and higher temperature, deviation may be greater (maximum : 8 seconds per 48 hours).
When the terminal is used for applications requiring high time precision, it is strongly recommended to synchronize the terminal with an
external clock.
Cleaning precautions
A dry cloth should be used to clean the terminal, especially the biometric sensor.
The use of acid liquids, alcohol or abrasive materials is prohibited.
Firmware release
To get the best of our technology, we recommend you to download and install the last firmware release (please refer to last page)
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
29
Documentation
Bibliography
Ref. 2016_2000022505 - MorphoAccess® 5G Series Bibliography
This document gives document’s references for MorphoAccess® 5G Series terminals. This document is in English.
Release note : for each firmware version, a release note is published describing the new features, the supported products, the potential
known issues, the upgrade / downgrade limitations, the recommendations, the potential restrictions…
North and South America: you may obtain these document by e-mailing cscenter@safrangroup.com with your name, phone number, MA
SIGMA serial number and “Send Links For MASIGMA Documents” in the subject line.
Other countries: please contact your sales representative.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
30
Notes
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
31
Contacts
2014_0000000530-V6
Technical Support and Hotline
North America
Mail: cscenter@safrangroup.com
Tel: +1 888 940 7477
South America
Mail: cscenter@safrangroup.com Tel: +1 714 575 2973
South Africa
Mail: sec.san.bio.support@morpho.com Tel: + 27 11 286 5855
For the latest firmware, software, document releases, and news, please check our websites :
North and South America : e-mailing cscenter@safrangroup.com with your name, phone number, MA
SIGMA serial number and “Send Links For MASIGMA Documents” in the subject line
Other countries : please visit our web site www.biometric-terminals.com. Morpho partners : to get your
log in and password for the private area, please contact your sales representative).
Copyright © 2017, Morpho. All rights reserved.
www.morpho.com
Reproduction in whole or in part in any form or medium without the express written permission of Morpho is prohibited. The trademarks identified herein are the trademarks of registered trademarks of Morpho, or other third party.
India:
Mail: support.morphoindia@safrangroup.com Tel: 0120-4699900
Europe and rest of the world: Mail: hotline.biometrics@safrangroup.com Tel: +33 1 30 20 30 40
293684580
-B
Loading...