Safran MA SIGMA, MA SIGMA WR, MA SIGMA iCLASS, MA SIGMA iClass WR, MA SIGMA Multi Quick User Manual

...
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
MorphoAccess
®
SIGMA Series
Quick User Guide
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
1
Table of Contents
2014_0000000530-V6
Color
Step
Content
One
Overview
Two
Wiring
Three
Communication
Four
ACP or SDAC
Five
Administration
Six
Software
Seven
Enrollment
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
2
MorphoAccess® SIGMA Overview
The MorphoAccess®SIGMA terminal has a
simple and ergonomic man-machine interface
designed for access control and Time & Attendance, with fingerprint recognition, contactless card authentication and PIN authentication options.
USB port (for
configuration and
settings with a
USB mass
storage key)
Step one : overview
USB host port
WR* product comes with a
sensor protection
cap (not displayed here)
Optional Wi-Fi
USB adaptor
(plugged at the back
of the terminal)
5“ WVGA
touchscreen LCD
Optical biometrical sensor
VGA Camera
Speaker
Microphone
HID® iCLASS™ 13,56MHz (SIGMA … ICLASS)
Or MIFAREDESFire 13,56MHz (SIGMA .. MULTI)
Or HID® Prox ® 125kHz (SIGMA .. PROX)
Optional Contactless Card reader.
Specific logo on cover when available
Status LED
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
3
QTY
ITEM
1
MorphoAccess
®
SIGMA terminal
1
Micro SD card installed
in the terminal
1
Wall Mount Plate
1
Battery
1
POE module
1
Protection Accessory (WR* product only)
1
Flat screw driver 0.4 x 2.0
1
Quick Installation Guide
1
WEEE notice
Indoor & Weather Resistant (WR) Checklist
*WR : Weather Resistant
Step one : overview
Electronic documentation is provided in Adobe® Acrobat® format (PDF). Adobe® Acrobat® Reader is available at http://www.adobe.com.
Product packaging checklist:
Micro SD card must be installed in the
terminal at start up (storage area for internal
database and terminal logs)
Micro SD card replacement:
Class 10 or higher, 1GB min, 32GB maxFormatted by the terminal. Windows® PC
may damage the content of the card and
make it inoperative.
Use only Brand Name cards. No name
card may have lower performances or lower life time.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
4
MorphoAccess® SIGMA Series
Step one : overview
Product
designation
Biometrics
(Fingerprint)
iCLASS
®
MIFARE
®
DESFire
®
NFC
Prox
®
Water
Resistant (*)
MA SIGMA
MA SIGMA WR
MA SIGMA
iCLASS
MA SIGMA
iClass WR
MA SIGMA Multi
MA SIGMA Multi WR
MA SIGMA Prox
MA SIGMA Prox WR
The MorphoAccess® SIGMA Series contains the following product variants:
Contactless Smart
card reader
MA stands for MorphoAccess®and WR stands for Water Resistant
(*) WR units must be installed according to installation guidelines on Quick Installation Guide
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
5
MorphoAccess® SIGMA terminal implementation
ACCESS CONTROL
SYSTEM
(*) OR EQUIVALENT
NON SECURED
AREA
ACCESS
CONTROLLER
TCP/IP, Wiegand, Dataclock, RS485 or RS422
ELECTRIC
LATCH (*)
SECURED
AREA
Dry Contact
MorphoAccess
®
Sigma Terminal
Dry Contact
ALARM
Step one : overview
The MorphoAccess®SIGMA Series terminal
Its role is to process the access request from the user. It performs access right checks using one-to-many biometric identification or one-to-one biometric verification, and/or RF card authentication, and/or PIN check.
A Door Electric Latch or equivalent such Deadbolt, Door Strike or Magnetic Lock (3rd party product)
The Access Controller sends a command to activate the latch if the access is granted (i.e. if the individual's User ID is listed in the Controller White List). Control of the latch is made through a dry contact..
An Alarm (3rd party product)
The MorphoAccess®terminal sends a message to the Access Controller, to activate the Alarm as soon as a malicious activity such as tamper or pulling, is detected.
To secure an access, Morpho recommends installing the MorphoAccess®SIGMA Series terminal as a part of a typical Access Control system, this consists of the components described below.
An Access Controller (3rd party product)
The MorphoAccess®terminal interfaces with an Access Controller
(using TCP/IP, Wiegand, Data Clock or RS485 protocol):
After user’s access rights checks, the MorphoAccess
®
terminal sends the result to the Access Controller (this message contains at least the User ID)
The Access Controller performs additional checks, and returns the
final decision (access granted/denied) to the MorphoAccess
®
terminal (which displays the result to the user), and to the door controller which opens the door (if the access has been granted).
A
A
B
B
D
D
C
C
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
6
MorphoAccess® SIGMA Access Control Modes
Step one : overview
(1) or the user enter their Identifier on the keypad, or a Wiegand frame is received from an external device
(2) stored on the contactless card or in the user record in the terminal’s local database
(3) There is no fingerprint image stored in the terminal, but only points of interest (minutiae) of each fingerprint
Identification
Authentication
Multifactor
Proxy
Access
control
a
pplication
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Remote application
that controls the
terminal through network commands
Access control
triggering
event A
user places a
finger on the
biometric sensor.
A user places
a
contactless
card in
front of
the reader (1)
Both
Identification
and Authentication
triggers are enabled.
Triggering events are selected
by the
remote application
Biometric check (if enabled)
The user’s captured
fingerprint template is matched against all fingerprint
templates in the
terminal database (3)
The user’s captured
fingerprint templated is
matched against
his reference
fingerprint templates
(2)
As per Identification or Authentication, depending on the triggering event
Selected
by the
remote application
Decision
to
display
result
signal to user
By Identification standalone application
By Authentication standalone application
By
running
s
tandalone
application
By remote application
The terminal can be configured in one of the modes described in the table below
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
7
Deployment Environments
Step one : overview
General precautions
Do not expose the terminal to extreme temperatures. When the environment is very dry, avoid synthetic carpeting near the MorphoAccess® SIGMA terminal, to
reduce the risk of unwanted electrostatic discharge.
Areas containing combustibles
Do not install the terminal in the vicinity of gas stations or any other installation containing flammable or
combustible gases or materials. The terminal is not designed to be intrinsically safe.
The terminal should be installed in controlled lighting conditions
Avoid biometric sensor exposure to a blinking light Avoid direct exposure of the biometric sensor to sunlight or to UV lights.
Operating temperature
-
20°to + 60 °C (- 4°to 140°F)
Operating
humidity
10 % < RH < 80 % (non condensing)
Storage
temperature
-
25°to + 70 °C (-13° to 158°F)
Storage
humidity
5% < RH < 95 %
IP code
IP65 rated for WR(*) products (once wall
-mounted)
(*) WR units must be installed according to installation guidelines on Quick Installation Guide
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
8
C
Wiring Overview
Step two : wiring
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
Power supply from electrical source shall be switched off before starting the installation. Before proceeding, make sure that the person in charge of installation and connections, is
properly connected to earth, in order to prevent Electrostatic Discharges (ESD).
1
6
2
5
4
3
Power Supply +12V
Power Ground
Tamper switch 2 Tamper switch 1
Digital Ground
Digital Ground
1
6
2
5
4
3
Wiegand IN 0 Wiegand IN 1
Wiegand OUT 0 Wiegand OUT 1
Wiegand LED 1 Wiegand LED 2
1
6
2
5
4
3
Digital Input 0 Digital Input 1
Digital Input 2
Digital Output 0
Digital Output 1
Digital Output 2
1
6
2
5
4
3
Relay_NO
RS422 RX-
RS422/485 TX+
RS422/485 TX-
Battery
Reset button
A
A
B
B
C
RJ-45
USB
µSD
D
D
Relay_COM
RS422 RX+
Connection: Insert cable in the round hole of the block connector. Disconnection: Insert flat screw driver (0.4x2.0max) in rectangular hole and pull the wire.
2014_0000000530-V6
This document and the information therein are the property of Morpho, They must not be copied or communicated to a third party without the prior written authorization of Morpho.
9
Power Wiring
Step two : wiring
External Power Supply: 12-24 Volts (regulated and filtered) 1 Amp min @12V,
CEE/EEC EN60950 standard compliant. A12 Volts power supply compliant with SIA's
Wiegand standard will also be suitable. If sharing power between devices, each unit must receive 1A (e.g. two units would require a 12vDC, 2A supply)
WARNING: Under powering may cause memory and data corruption; over powering may cause hardware damage. Both of these situations will void the
warranty
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is recommended.
1
A
2 3
Power Supply +12V
Power Ground
Inversion of +12V and GND will damage the product.
B C D
Gauge
AWG
Diameter
(mm)
Maximum drop voltage (V)
at 1m at 5m at 10m
20 0.81 0.03 0.17 0.33 22 0.64 0.05 0.26 0.53 24 0.51 0.08 0.42 0.84
Morpho recommends using a gauge AWG20 for 12V power supply. The voltage measured on the product block connector of the terminal must be equal
to 12V-24V (-15% / +10%). The table below, shows the maximum voltage drop between the power source and the
terminal, depending on the length of the cable.